Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 32.1
edited by Craig Lewis
on 2024/09/30 17:35
on 2024/09/30 17:35
Change comment:
There is no comment for this version
To version 24.2
edited by Craig Lewis
on 2024/05/22 21:45
on 2024/05/22 21:45
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -28,10 +28,8 @@ 28 28 ((( 29 29 * ShowRunnerCLC™ version 3.014 or newer required 30 30 * Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 31 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox and confirm all hardware (NETs and LINKs) are onlineprior to running the discovery commands31 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 32 32 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 33 -* ZUMLINK-IOs will not be discovered (Expected to be discoverable in future ShowRunnerCLC™ release) 34 -* ZUMLINK-KPs will not be discovered on older versions of ShowRunnerCLC™ (v3.058 or newer will discover keypads and set as remote type) 35 35 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 36 36 ))) 37 37 ... ... @@ -53,8 +53,7 @@ 53 53 1**. configure keypad logic 54 54 1**. configure occupancy sensor settings 55 55 1**. calibrate photocell(s) 56 -1*. Set hostnames for the ZUMNETs. 57 -1**. Zūm discovery will bring in hostnames. 54 +1*. Set hostnames for the ZUMNETs for easy identification when hardware is discovered. 58 58 1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 59 59 1*. If firmware was out-of-date, then this step should have already been completed 60 60 1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs ... ... @@ -88,7 +88,6 @@ 88 88 * ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 89 89 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 90 90 * Plug loads will not appear in the ShowRunnerCLC™ UI 91 -* Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER 92 92 ))) 93 93 94 94 (% class="box infomessage" id="HCaution:" %)