Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 30.1
edited by Craig Lewis
on 2024/09/30 17:33
on 2024/09/30 17:33
Change comment:
There is no comment for this version
To version 4.1
edited by Alexander Mott
on 2022/09/22 21:50
on 2022/09/22 21:50
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Discovery1 +Zūm Autodiscovery - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Program Configuration.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. craig\.lewis@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,14 +9,6 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 - 5 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 -))) 8 - 9 9 (% class="box warningmessage" %) 10 10 ((( 11 -This article is about automatically building a S howRunnerCLC™ configuration using the ZūmDiscovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 12 12 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 13 13 ))) 14 14 ... ... @@ -16,119 +16,70 @@ 16 16 {{toc/}} 17 17 {{/box}} 18 18 19 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 11 +(% class="row" %) 12 +((( 13 +If Zūm Net devices have been configured using Crestron's Zūm App 20 20 21 - Thereare certain pre-requisites and limitationswhen building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustmentsto the final configuration, such as changing keypad types and moving loads between areas.15 += Zūm Wired = 22 22 23 - = Zūm Wired Discovery =17 +Lorem 24 24 25 -= =Notesand Limitations ==19 += Zūm Wireless = 26 26 27 -(% class="box warningmessage" %) 28 -((( 29 -* ShowRunnerCLC™ version 3.014 or newer required 30 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 31 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox and confirm all hardware (NETs and LINKs) are online prior to running the discovery commands 32 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 33 -* ZUMLINK-KPs will not be discovered on older versions of ShowRunnerCLC™ (v3.058 or newer) 34 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 35 -))) 36 36 37 -== Steps == 22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads. 23 +*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 +*Plug loads do not appear in the UI* 38 38 39 -1. [[Install ShowRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 40 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 41 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 42 -1*. Connect to the first ZUMNET-JBOX in Toolbox 43 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 44 -1**. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 45 -1**. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 46 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 47 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 48 -1*. Repeat the above steps for all ZUMNET-JBOXs 49 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 50 -1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 51 -1*. Commission room through the app 52 -1**. configure keypad logic 53 -1**. configure occupancy sensor settings 54 -1**. calibrate photocell(s) 55 -1*. Set hostnames for the ZUMNETs. 56 -1**. Zūm discovery will bring in hostnames. 57 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 58 -1*. If firmware was out-of-date, then this step should have already been completed 59 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 60 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 61 -1*. If firmware was out-of-date, then this step should have already been completed 62 -1*. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 63 -1*. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 64 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 65 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 66 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 67 -1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 68 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 69 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 70 -1. Run the command: ##sr discover zumnet true false## 71 -1*. This command tells ShowRunnerCLC™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 72 -1. Run the command: ##sr discover zumnet true true## 73 -1*. This command tells ShowRunnerCLC™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 74 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 75 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 76 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 26 +== Pre-Requisites: == 77 77 78 -= Zūm Wireless Discovery = 79 - 80 -== Notes and Limitations == 81 - 82 -(% class="box warningmessage" %) 83 -((( 84 -* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 85 -** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 86 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 87 -* ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 88 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 89 -* Plug loads will not appear in the ShowRunnerCLC™ UI 90 -* Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER 28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway 30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored. 91 91 ))) 92 92 93 -(% class="box in fomessage" id="HCaution:" %)33 +(% class="box warningmessage" id="HCaution:" %) 94 94 ((( 95 -**Note:** S howRunnerCLC™ has two different approaches for Zūm WirelessDiscovery35 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery 96 96 97 -1. **Manual RF Gateway Assignment** - S howRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.98 -1. **Claim All RF Gateways** - S howRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network.37 +1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 38 +1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 99 99 ))) 100 100 101 -== Manual RF Gateway Assignment Instructions == 41 +(% class="row" %) 42 +((( 43 +== Option 1: Manual RF Gateway Claiming: == 102 102 103 -Use this method if you have multiple ShowRunner CLC™instances on the same network or have gateways used by other Crestron systems.45 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems. 104 104 105 105 * Connect to the processor's console with Toolbox or your favorite SSH client. 106 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.107 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.108 -* For each gateway that you'd like this instance of S HOWRUNNER™to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™,proceed to the next step.109 -* Type ##sr discover zummeshfalse##and press enter.110 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 111 -* When the discovery is finished type ##sr save##and press enter to save the updated config.CLC™must be restarted to complete the acquire process.112 -* Type ##progreset##and press enter to restart ShowRunnerCLC™113 -* Once S HOWRUNNER™has finished restarting type##sr discover zummeshfalse##and press enter.CLC™will be able to acquire the loads attached to the Zūm rooms at this point.114 -* Once completed S HOWRUNNER™is now ready for full Zūm control48 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 49 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 50 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step. 51 +* Type "//sr discover zum false//" and press enter. 52 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 53 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 54 +* Type "//progreset//" and press enter to restart ShowRunner 55 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 56 +* Once completed ShowRunner is now ready for full Zum control 115 115 116 -== Claim All RFGatewaysInstructions==58 +== Option 2: Claim All Gateways: == 117 117 118 -Use this method when you have a single ShowRunner CLC™instance on a local network with all gateways being used for ShowRunnerCLC™.60 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner. 119 119 120 120 * Connect to the processor's console with Toolbox or your favorite SSH client. 121 -* Type ##sr discover zummeshtrue##and press enter.122 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 123 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into,CLC™must be restarted to complete the acquire process.124 -* Type ##progreset##and press enter to restart ShowRunnerCLC™125 -* Once ShowRunner CLC™has finished restarting type##sr discover zummeshfalse##and press enter.CLC™will be able to acquire the loads attached to the Zūm rooms at this point.126 -* Once completed ShowRunner CLC™is now ready for full Zūm control63 +* Type "//sr discover zum true//" and press enter. 64 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 65 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 66 +* Type "//progreset//" and press enter to restart ShowRunner 67 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 68 +* Once completed ShowRunner is now ready for full Zum control 127 127 128 128 == Examples == 129 129 130 -=== Manual Example === 131 131 73 +=== Example for Option 1: === 74 + 132 132 {{{MC4>sr devmgr ethernet query 133 133 Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 134 134 MC4>sr devmgr ethernet show devices ... ... @@ -146,7 +146,7 @@ 146 146 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 147 147 Claimed ethernet device: CEN-GWEXER-9E6ADA 148 148 MC4>Update request from IP-ID-30 in Program 01 149 -MC4>sr discover zum meshfalse92 +MC4>sr discover zum false 150 150 Starting Zum Discovery without gateway claiming 151 151 MC4>Performing Discovery on 1 Gateways. 152 152 Evaluating 3 Devices on Gateway 30 ... ... @@ -179,7 +179,7 @@ 179 179 MC4>progreset 180 180 ... 181 181 CI ShowRunner startup completed successfully in 8072ms 182 -MC4>sr discover zum meshfalse125 +MC4>sr discover zum false 183 183 Starting Zum Discovery without gateway claiming 184 184 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 185 185 Performing Discovery on 1 Gateways. ... ... @@ -230,9 +230,9 @@ 230 230 Removed Loads: 0 231 231 Zum Discovery Finished}}} 232 232 233 -=== Claim AllExample ===176 +=== Example for Option 2: === 234 234 235 -{{{MC4>sr discover zum meshtrue178 +{{{MC4>sr discover zum true 236 236 Starting Zum Discovery with gateway claiming 237 237 MC4>Found 1 Gateways to check. 238 238 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -268,7 +268,7 @@ 268 268 MC4>progreset 269 269 ... 270 270 CI ShowRunner startup completed successfully in 8072ms 271 -MC4>sr discover zum meshfalse214 +MC4>sr discover zum false 272 272 Starting Zum Discovery without gateway claiming 273 273 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 274 274 Performing Discovery on 1 Gateways. ... ... @@ -319,3 +319,4 @@ 319 319 Removed Loads: 0 320 320 Zum Discovery Finished 321 321 }}} 265 +)))