Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 28.1
edited by Austin Weygandt
on 2024/08/02 20:42
on 2024/08/02 20:42
Change comment:
There is no comment for this version
To version 19.1
edited by Scott Kohlmann
on 2023/04/21 13:58
on 2023/04/21 13:58
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Program Configuration.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. austin\.weygandt@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,14 +1,13 @@ 1 1 (% class="box errormessage" %) 2 2 ((( 3 - **IMPORTANT:** When using ShowRunnerCLC™ witha ZUM-HUB4, **do not** discoverZūm RoomsusingtheCrestronHUB4 Web UI. Duringdiscovery,the HUB4 will claimZUMNET-JBOXsand preventShowRunnerCLC™fromauto-discoveringor registeringtheZūmhardwarefor itself.3 +WARNING: Cresnet Discovery is not currently working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. 4 4 5 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 5 +Downgrade ShowRunnerCLC™ to v3.018 in order to auto-discover hardware. ShowRunnerCLC™ can be subsequently upgraded once discovery is complete. 7 7 ))) 8 8 9 9 (% class="box warningmessage" %) 10 10 ((( 11 -This article is about automatically building a ShowRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide. SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].10 +This article is about automatically building a ShowRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 12 12 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 13 13 ))) 14 14 ... ... @@ -30,7 +30,6 @@ 30 30 * Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 31 31 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 32 32 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 33 -* ZUMLINK-KPs will not be discovered (Expected to be discoverable in future release) 34 34 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 35 35 ))) 36 36 ... ... @@ -47,13 +47,7 @@ 47 47 1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 48 48 1*. Repeat the above steps for all ZUMNET-JBOXs 49 49 1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 50 -1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 51 -1*. Commission room through the app 52 -1**. configure keypad logic 53 -1**. configure occupancy sensor settings 54 -1**. calibrate photocell(s) 55 -1*. Set hostnames for the ZUMNETs. 56 -1**. Zūm discovery will bring in hostnames. 48 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 57 57 1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 58 58 1*. If firmware was out-of-date, then this step should have already been completed 59 59 1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs ... ... @@ -87,7 +87,6 @@ 87 87 * ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 88 88 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 89 89 * Plug loads will not appear in the ShowRunnerCLC™ UI 90 -* Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER 91 91 ))) 92 92 93 93 (% class="box infomessage" id="HCaution:" %)