Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 26.1
edited by Craig Lewis
on 2024/05/29 15:37
on 2024/05/29 15:37
Change comment:
There is no comment for this version
To version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
on 2022/09/23 00:00
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Program Configuration.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. craig\.lewis@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,14 +9,6 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 - 5 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 -))) 8 - 9 9 (% class="box warningmessage" %) 10 10 ((( 11 -This article is about automatically building a S howRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 12 12 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 13 13 ))) 14 14 ... ... @@ -16,113 +16,104 @@ 16 16 {{toc/}} 17 17 {{/box}} 18 18 19 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 11 +(% class="row" %) 12 +((( 13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 20 20 21 -There are certain pre-requisites and limitations when building a S howRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.15 +There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 22 22 23 23 = Zūm Wired Discovery = 24 24 25 25 == Notes and Limitations == 26 26 27 -(% class="box warningmessage" %) 28 -((( 29 -* ShowRunnerCLC™ version 3.014 or newer required 30 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 21 +* SHOWRUNNER™ version 3.014 or newer required 22 +* Zūm Wired firmware version 1.02.10 or greater required 31 31 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 32 32 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 33 -* ZUMLINK-KPs will not be discovered (Expected to be discoverable in future release) 34 34 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 35 -))) 36 36 37 37 == Steps == 38 38 39 -1. [[Install S howRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary29 +1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 40 40 1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 41 41 1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 42 42 1*. Connect to the first ZUMNET-JBOX in Toolbox 43 43 1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 44 -1**. Note: The S howRunnerCLC™ built-in DHCP server is not meant to be used in production45 -1**. If the S howRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses34 +1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 35 +1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 46 46 1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 47 47 1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 48 48 1*. Repeat the above steps for all ZUMNET-JBOXs 49 49 1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 50 -1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 51 -1*. Commission room through the app 52 -1**. configure keypad logic 53 -1**. configure occupancy sensor settings 54 -1**. calibrate photocell(s) 55 -1*. Set hostnames for the ZUMNETs. 56 -1**. Zūm discovery will bring in hostnames. 40 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 57 57 1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 58 58 1*. If firmware was out-of-date, then this step should have already been completed 59 59 1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 60 60 1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 61 61 1*. If firmware was out-of-date, then this step should have already been completed 62 -1*. Note: The S howRunnerCLC™ built-in DHCP server is not meant to be used in production63 -1*. If the S howRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses46 +1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 47 +1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 64 64 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 65 65 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 66 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 67 -1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 68 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 50 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 69 69 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 70 70 1. Run the command: ##sr discover zumnet true false## 71 -1*. This command tells ShowRunnerCLC™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 53 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 54 +1*. One area will be created per ZUMNET-JBOX 72 72 1. Run the command: ##sr discover zumnet true true## 73 -1*. This command tells ShowRunnerCLC™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 74 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 56 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 75 75 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 76 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 58 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 59 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 77 77 78 78 = Zūm Wireless Discovery = 79 79 80 80 == Notes and Limitations == 81 81 82 -(% class="box warningmessage" %) 83 -((( 84 -* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 85 -** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 65 +* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 66 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 86 86 * ZUM-NETBRIDGES must already be acquired to their respective gateway 87 -* S howRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices68 +* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 88 88 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 89 -* Plug loads will not appear in the S howRunnerCLC™ UI70 +* Plug loads will not appear in the SHOWRUNNER™ UI 90 90 ))) 91 91 92 -(% class="box in fomessage" id="HCaution:" %)73 +(% class="box warningmessage" id="HCaution:" %) 93 93 ((( 94 -**Note:** S howRunnerCLC™ has two different approaches for Zūm Wireless Discovery75 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery 95 95 96 -1. **Manual RF Gateway Assignment** - S howRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.97 -1. **Claim All RF Gateways** - S howRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network.77 +1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 78 +1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 98 98 ))) 99 99 81 +(% class="row" %) 82 +((( 100 100 == Manual RF Gateway Assignment Instructions == 101 101 102 -Use this method if you have multiple S howRunnerCLC™ instances on the same network or have gateways used by other Crestron systems.85 +Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 103 103 104 104 * Connect to the processor's console with Toolbox or your favorite SSH client. 105 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.106 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.107 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step.108 -* Type ##sr discover zummeshfalse##and press enter.88 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 89 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 90 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 91 +* Type "//sr discover zum false//" and press enter. 109 109 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 110 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process.111 -* Type ##progreset##and press enter to restart ShowRunnerCLC™112 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.93 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 94 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 95 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 113 113 * Once completed SHOWRUNNER™ is now ready for full Zūm control 114 114 115 115 == Claim All RF Gateways Instructions == 116 116 117 -Use this method when you have a single S howRunnerCLC™ instance on a local network with all gateways being used for ShowRunnerCLC™.100 +Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 118 118 119 119 * Connect to the processor's console with Toolbox or your favorite SSH client. 120 -* Type ##sr discover zummeshtrue##and press enter.103 +* Type "//sr discover zum true//" and press enter. 121 121 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 122 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process.123 -* Type ##progreset##and press enter to restart ShowRunnerCLC™124 -* Once S howRunnerCLC™ has finished restarting type##sr discover zummeshfalse##and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.125 -* Once completed S howRunnerCLC™ is now ready for full Zūm control105 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 106 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 107 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 108 +* Once completed SHOWRUNNER™ is now ready for full Zūm control 126 126 127 127 == Examples == 128 128 ... ... @@ -145,7 +145,7 @@ 145 145 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 146 146 Claimed ethernet device: CEN-GWEXER-9E6ADA 147 147 MC4>Update request from IP-ID-30 in Program 01 148 -MC4>sr discover zum meshfalse131 +MC4>sr discover zum false 149 149 Starting Zum Discovery without gateway claiming 150 150 MC4>Performing Discovery on 1 Gateways. 151 151 Evaluating 3 Devices on Gateway 30 ... ... @@ -178,7 +178,7 @@ 178 178 MC4>progreset 179 179 ... 180 180 CI ShowRunner startup completed successfully in 8072ms 181 -MC4>sr discover zum meshfalse164 +MC4>sr discover zum false 182 182 Starting Zum Discovery without gateway claiming 183 183 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 184 184 Performing Discovery on 1 Gateways. ... ... @@ -231,7 +231,7 @@ 231 231 232 232 === Claim All Example === 233 233 234 -{{{MC4>sr discover zum meshtrue217 +{{{MC4>sr discover zum true 235 235 Starting Zum Discovery with gateway claiming 236 236 MC4>Found 1 Gateways to check. 237 237 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -267,7 +267,7 @@ 267 267 MC4>progreset 268 268 ... 269 269 CI ShowRunner startup completed successfully in 8072ms 270 -MC4>sr discover zum meshfalse253 +MC4>sr discover zum false 271 271 Starting Zum Discovery without gateway claiming 272 272 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 273 273 Performing Discovery on 1 Gateways. ... ... @@ -318,3 +318,4 @@ 318 318 Removed Loads: 0 319 319 Zum Discovery Finished 320 320 }}} 304 +)))