Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 24.3
edited by Craig Lewis
on 2024/05/22 21:47
on 2024/05/22 21:47
Change comment:
There is no comment for this version
To version 5.1
edited by Alexander Mott
on 2022/09/22 21:55
on 2022/09/22 21:55
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Discovery1 +Zūm Autodiscovery - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Program Configuration.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. craig\.lewis@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,14 +9,6 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 - 5 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 -))) 8 - 9 9 (% class="box warningmessage" %) 10 10 ((( 11 -This article is about automatically building a S howRunnerCLC™ configuration using the ZūmDiscovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 12 12 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 13 13 ))) 14 14 ... ... @@ -16,116 +16,67 @@ 16 16 {{toc/}} 17 17 {{/box}} 18 18 19 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 20 - 21 -There are certain pre-requisites and limitations when building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 22 - 23 -= Zūm Wired Discovery = 24 - 25 -== Notes and Limitations == 26 - 27 -(% class="box warningmessage" %) 11 +(% class="row" %) 28 28 ((( 29 -* ShowRunnerCLC™ version 3.014 or newer required 30 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 31 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 32 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 33 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 34 -))) 13 +If Zūm Net devices have been configured using Crestron's Zūm App 35 35 36 -= =Steps==15 += Zūm Wired = 37 37 38 -1. [[Install ShowRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 39 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 40 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 41 -1*. Connect to the first ZUMNET-JBOX in Toolbox 42 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 43 -1**. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 44 -1**. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 45 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 46 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 47 -1*. Repeat the above steps for all ZUMNET-JBOXs 48 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 49 -1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 50 -1*. Commission room through the app 51 -1**. configure keypad logic 52 -1**. configure occupancy sensor settings 53 -1**. calibrate photocell(s) 54 -1*. Set hostnames for the ZUMNETs. 55 -1**. Zūm discovery will bring in hostnames. 56 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 57 -1*. If firmware was out-of-date, then this step should have already been completed 58 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 59 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 60 -1*. If firmware was out-of-date, then this step should have already been completed 61 -1*. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 62 -1*. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 63 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 64 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 65 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 66 -1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 67 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 68 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 69 -1. Run the command: ##sr discover zumnet true false## 70 -1*. This command tells ShowRunnerCLC™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 71 -1. Run the command: ##sr discover zumnet true true## 72 -1*. This command tells ShowRunnerCLC™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 73 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 74 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 75 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 17 +Lorem 76 76 77 -= Zūm Wireless Discovery=19 += Zūm Wireless = 78 78 79 -== Notes and Limitations == 21 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads. 22 +*Disconnect from the gateway before discovery as they cannot support multiple connections* 23 +*Plug loads do not appear in the UI* 80 80 81 -(% class="box warningmessage" %) 82 -((( 83 -* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 84 -** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 85 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 86 -* ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 87 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 88 -* Plug loads will not appear in the ShowRunnerCLC™ UI 25 +== Pre-Requisites: == 26 + 27 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 28 +* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway 29 +* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored. 89 89 ))) 90 90 91 -(% class="box in fomessage" id="HCaution:" %)32 +(% class="box warningmessage" id="HCaution:" %) 92 92 ((( 93 -**Note:** S howRunnerCLC™ has two different approaches for Zūm WirelessDiscovery34 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery 94 94 95 -1. **Manual RF Gateway Assignment** - S howRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.96 -1. **Claim All RF Gateways** - S howRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network.36 +1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 37 +1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 97 97 ))) 98 98 99 -== Manual RF Gateway Assignment Instructions == 40 +(% class="row" %) 41 +((( 42 +== Manual RF Gateway Claiming == 100 100 101 -Use this method if you have multiple S howRunnerCLC™ instances on the same network or have gateways used by other Crestron systems.44 +Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 102 102 103 103 * Connect to the processor's console with Toolbox or your favorite SSH client. 104 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.105 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.106 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step.107 -* Type ##sr discover zummeshfalse##and press enter.47 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 48 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 49 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 50 +* Type "//sr discover zum false//" and press enter. 108 108 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 109 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process.110 -* Type ##progreset##and press enter to restart ShowRunnerCLC™111 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.52 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 53 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 54 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 112 112 * Once completed SHOWRUNNER™ is now ready for full Zūm control 113 113 114 -== Claim All RF Gateways Instructions==57 +== Claim All RF Gateways == 115 115 116 -Use this method when you have a single S howRunnerCLC™ instance on a local network with all gateways being used for ShowRunnerCLC™.59 +Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 117 117 118 118 * Connect to the processor's console with Toolbox or your favorite SSH client. 119 -* Type ##sr discover zummeshtrue##and press enter.62 +* Type "//sr discover zum true//" and press enter. 120 120 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 121 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process.122 -* Type ##progreset##and press enter to restart ShowRunnerCLC™123 -* Once S howRunnerCLC™ has finished restarting type##sr discover zummeshfalse##and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.124 -* Once completed S howRunnerCLC™ is now ready for full Zūm control64 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 65 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 66 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 67 +* Once completed SHOWRUNNER™ is now ready for full Zūm control 125 125 126 126 == Examples == 127 127 128 -=== Manual Example === 71 +=== Claim Selectively (Manual) Example === 129 129 130 130 {{{MC4>sr devmgr ethernet query 131 131 Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess ... ... @@ -144,7 +144,7 @@ 144 144 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 145 145 Claimed ethernet device: CEN-GWEXER-9E6ADA 146 146 MC4>Update request from IP-ID-30 in Program 01 147 -MC4>sr discover zum meshfalse90 +MC4>sr discover zum false 148 148 Starting Zum Discovery without gateway claiming 149 149 MC4>Performing Discovery on 1 Gateways. 150 150 Evaluating 3 Devices on Gateway 30 ... ... @@ -177,7 +177,7 @@ 177 177 MC4>progreset 178 178 ... 179 179 CI ShowRunner startup completed successfully in 8072ms 180 -MC4>sr discover zum meshfalse123 +MC4>sr discover zum false 181 181 Starting Zum Discovery without gateway claiming 182 182 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 183 183 Performing Discovery on 1 Gateways. ... ... @@ -230,7 +230,7 @@ 230 230 231 231 === Claim All Example === 232 232 233 -{{{MC4>sr discover zum meshtrue176 +{{{MC4>sr discover zum true 234 234 Starting Zum Discovery with gateway claiming 235 235 MC4>Found 1 Gateways to check. 236 236 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -266,7 +266,7 @@ 266 266 MC4>progreset 267 267 ... 268 268 CI ShowRunner startup completed successfully in 8072ms 269 -MC4>sr discover zum meshfalse212 +MC4>sr discover zum false 270 270 Starting Zum Discovery without gateway claiming 271 271 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 272 272 Performing Discovery on 1 Gateways. ... ... @@ -317,3 +317,4 @@ 317 317 Removed Loads: 0 318 318 Zum Discovery Finished 319 319 }}} 263 +)))