Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 24.2
edited by Craig Lewis
on 2024/05/22 21:45
on 2024/05/22 21:45
Change comment:
There is no comment for this version
To version 1.2
edited by Alexander Mott
on 2022/09/22 21:31
on 2022/09/22 21:31
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Discovery1 +Zūm Autodiscovery - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Program Configuration.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. craig\.lewis@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,14 +9,6 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 - 5 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 -))) 8 - 9 9 (% class="box warningmessage" %) 10 10 ((( 11 -This article is about automatically building a S howRunnerCLC™ configuration using the ZūmDiscovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 12 12 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 13 13 ))) 14 14 ... ... @@ -16,303 +16,31 @@ 16 16 {{toc/}} 17 17 {{/box}} 18 18 19 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 20 - 21 -There are certain pre-requisites and limitations when building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 22 - 23 -= Zūm Wired Discovery = 24 - 25 -== Notes and Limitations == 26 - 27 -(% class="box warningmessage" %) 11 +(% class="row" %) 28 28 ((( 29 -* ShowRunnerCLC™ version 3.014 or newer required 30 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 31 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 32 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 33 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 34 -))) 13 +Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum. 35 35 36 -= =Steps==15 += Para 1 = 37 37 38 -1. [[Install ShowRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 39 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 40 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 41 -1*. Connect to the first ZUMNET-JBOX in Toolbox 42 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 43 -1**. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 44 -1**. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 45 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 46 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 47 -1*. Repeat the above steps for all ZUMNET-JBOXs 48 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 49 -1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 50 -1*. Commission room through the app 51 -1**. configure keypad logic 52 -1**. configure occupancy sensor settings 53 -1**. calibrate photocell(s) 54 -1*. Set hostnames for the ZUMNETs for easy identification when hardware is discovered. 55 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 56 -1*. If firmware was out-of-date, then this step should have already been completed 57 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 58 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 59 -1*. If firmware was out-of-date, then this step should have already been completed 60 -1*. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 61 -1*. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 62 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 63 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 64 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 65 -1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 66 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 67 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 68 -1. Run the command: ##sr discover zumnet true false## 69 -1*. This command tells ShowRunnerCLC™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 70 -1. Run the command: ##sr discover zumnet true true## 71 -1*. This command tells ShowRunnerCLC™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 72 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 73 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 74 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 17 +Lorem 75 75 76 -= ZūmWirelessDiscovery=19 +== Sub 1 == 77 77 78 - == Notes and Limitations ==21 +Lorem 79 79 80 -(% class="box warningmessage" %) 81 -((( 82 -* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 83 -** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 84 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 85 -* ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 86 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 87 -* Plug loads will not appear in the ShowRunnerCLC™ UI 88 -))) 23 +== Sub 2 == 89 89 90 -(% class="box infomessage" id="HCaution:" %) 91 -((( 92 -**Note:** ShowRunnerCLC™ has two different approaches for Zūm Wireless Discovery 25 +Lorem 93 93 94 -1. **Manual RF Gateway Assignment** - ShowRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 95 -1. **Claim All RF Gateways** - ShowRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network. 96 -))) 27 += Para 2 = 97 97 98 - == Manual RF Gateway Assignment Instructions ==29 +Lorem 99 99 100 - Usethis method if you have multipleShowRunnerCLC™ instances on the same network or have gateways usedbyotherCrestron systems.31 +== Sub 1 == 101 101 102 -* Connect to the processor's console with Toolbox or your favorite SSH client. 103 -* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways. 104 -* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices. 105 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step. 106 -* Type ##sr discover zummesh false## and press enter. 107 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 108 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process. 109 -* Type ##progreset## and press enter to restart ShowRunnerCLC™ 110 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point. 111 -* Once completed SHOWRUNNER™ is now ready for full Zūm control 33 +Lorem 112 112 113 -== Claim All RF Gateways Instructions==35 +== Sub 2 == 114 114 115 -Use this method when you have a single ShowRunnerCLC™ instance on a local network with all gateways being used for ShowRunnerCLC™. 116 - 117 -* Connect to the processor's console with Toolbox or your favorite SSH client. 118 -* Type ##sr discover zummesh true## and press enter. 119 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 120 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process. 121 -* Type ##progreset## and press enter to restart ShowRunnerCLC™ 122 -* Once ShowRunnerCLC™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point. 123 -* Once completed ShowRunnerCLC™ is now ready for full Zūm control 124 - 125 -== Examples == 126 - 127 -=== Manual Example === 128 - 129 -{{{MC4>sr devmgr ethernet query 130 -Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 131 -MC4>sr devmgr ethernet show devices 132 - 133 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 134 -| Adapter | Hostname | IP Address | IP-ID | ID | 135 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 136 -| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 | 137 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 138 -| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] | 139 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 140 -| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] | 141 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 142 - 143 -MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 144 -Claimed ethernet device: CEN-GWEXER-9E6ADA 145 -MC4>Update request from IP-ID-30 in Program 01 146 -MC4>sr discover zummesh false 147 -Starting Zum Discovery without gateway claiming 148 -MC4>Performing Discovery on 1 Gateways. 149 -Evaluating 3 Devices on Gateway 30 150 -Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 151 -Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 152 -Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 03 153 -Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 154 -Dev: ZUM-NETBRIDGE addrssing to RF ID: 04 155 -Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 04 156 -Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 157 -Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 158 -Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 159 -Querying cresnet 160 -Discovering Zum Loads on 1 Gateways. 161 -Discovering Zum Loads on 3 Devices. 162 -NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 163 -Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 164 -NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 165 -Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 166 -NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 167 -Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 168 -RF Gateways: 0 169 -RF Devices: 3 170 -New Loads: 0 171 -Modified Loads: 0 172 -Removed Loads: 0 173 -Zum Discovery Finished 174 -MC4>sr save 175 -Saved config 176 -MC4>progreset 177 -... 178 -CI ShowRunner startup completed successfully in 8072ms 179 -MC4>sr discover zummesh false 180 -Starting Zum Discovery without gateway claiming 181 -MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 182 -Performing Discovery on 1 Gateways. 183 -Evaluating 3 Devices on Gateway 30 184 -Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 185 -Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 03 186 -Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 187 -Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 04 188 -Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 189 -Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 05 190 -Discovering Zum Loads on 1 Gateways. 191 -Discovering Zum Loads on 3 Devices. 192 -Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 193 -Evaluating Device: ZUM-JBOX-20A-PLUG ShortAddress: 0000 Type: PlugLoad 194 -Evaluating Device: ZUM-KP10C-BATT ShortAddress: 52E5 Type: Keypad 195 -Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: DAF1 Type: OccupancySensor 196 -Evaluating Device: ZUM-JBOX-5A-LV ShortAddress: 92EF Type: DimmableLoad 197 -Load: Load37615 Added 198 -NETBIRDGE: NewLoads: 1 ModifiedLoads: 0 RemovedLoads: 0 199 -Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 200 -Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 201 -Evaluating Device: ZUM-DALI ShortAddress: 740D Type: Unknown 202 -Evaluating Device: ZUM-5A-LV ShortAddress: 0482 Type: DimmableLoad 203 -Load: Load1154 Added 204 -Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 0000 Type: DimmableLoad 205 -Load: Load0 Added 206 -Evaluating Device: ZUM-KP10C-BATT ShortAddress: D766 Type: Keypad 207 -Evaluating Device: ZUM-OL-PHO-BATT ShortAddress: 95ED Type: Photocell 208 -Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: 44C2 Type: OccupancySensor 209 -Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 210 -Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 211 -NETBIRDGE: NewLoads: 2 ModifiedLoads: 0 RemovedLoads: 0 212 -Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 213 -Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 214 -Evaluating Device: ZUM-SIM ShortAddress: 0000 Type: OccupancySensor, PartitionSensor 215 -Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: EBCF Type: DimmableLoad 216 -Load: Load60367 Added 217 -Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 3CC1 Type: DimmableLoad 218 -Load: Load15553 Added 219 -Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: F94A Type: DimmableLoad 220 -Load: Load63818 Added 221 -NETBIRDGE: NewLoads: 3 ModifiedLoads: 0 RemovedLoads: 0 222 -Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 223 -RF Gateways: 0 224 -RF Devices: 3 225 -New Loads: 6 226 -Modified Loads: 0 227 -Removed Loads: 0 228 -Zum Discovery Finished}}} 229 - 230 -=== Claim All Example === 231 - 232 -{{{MC4>sr discover zummesh true 233 -Starting Zum Discovery with gateway claiming 234 -MC4>Found 1 Gateways to check. 235 -Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 236 -Update request from IP-ID-30 in Program 01 237 -Claimed 1 Gateways. Waiting for queries to finish. 238 -Performing Discovery on 1 Gateways. 239 -Evaluating 3 Devices on Gateway 30 240 -Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 241 -Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 242 -Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 03 243 -Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 244 -Dev: ZUM-NETBRIDGE addrssing to RF ID: 04 245 -Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 04 246 -Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 247 -Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 248 -Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 249 -Discovering Zum Loads on 1 Gateways. 250 -Discovering Zum Loads on 3 Devices. 251 -NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 252 -Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 253 -NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 254 -Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 255 -NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 256 -Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 257 -RF Gateways: 0 258 -RF Devices: 3 259 -New Loads: 0 260 -Modified Loads: 0 261 -Removed Loads: 0 262 -Zum Discovery Finished 263 -MC4>sr save 264 -Saved config 265 -MC4>progreset 266 -... 267 -CI ShowRunner startup completed successfully in 8072ms 268 -MC4>sr discover zummesh false 269 -Starting Zum Discovery without gateway claiming 270 -MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 271 -Performing Discovery on 1 Gateways. 272 -Evaluating 3 Devices on Gateway 30 273 -Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 274 -Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 03 275 -Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 276 -Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 04 277 -Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 278 -Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 05 279 -Discovering Zum Loads on 1 Gateways. 280 -Discovering Zum Loads on 3 Devices. 281 -Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 282 -Evaluating Device: ZUM-JBOX-20A-PLUG ShortAddress: 0000 Type: PlugLoad 283 -Evaluating Device: ZUM-KP10C-BATT ShortAddress: 52E5 Type: Keypad 284 -Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: DAF1 Type: OccupancySensor 285 -Evaluating Device: ZUM-JBOX-5A-LV ShortAddress: 92EF Type: DimmableLoad 286 -Load: Load37615 Added 287 -NETBIRDGE: NewLoads: 1 ModifiedLoads: 0 RemovedLoads: 0 288 -Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 289 -Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 290 -Evaluating Device: ZUM-DALI ShortAddress: 740D Type: Unknown 291 -Evaluating Device: ZUM-5A-LV ShortAddress: 0482 Type: DimmableLoad 292 -Load: Load1154 Added 293 -Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 0000 Type: DimmableLoad 294 -Load: Load0 Added 295 -Evaluating Device: ZUM-KP10C-BATT ShortAddress: D766 Type: Keypad 296 -Evaluating Device: ZUM-OL-PHO-BATT ShortAddress: 95ED Type: Photocell 297 -Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: 44C2 Type: OccupancySensor 298 -Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 299 -Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 300 -NETBIRDGE: NewLoads: 2 ModifiedLoads: 0 RemovedLoads: 0 301 -Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 302 -Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 303 -Evaluating Device: ZUM-SIM ShortAddress: 0000 Type: OccupancySensor, PartitionSensor 304 -Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: EBCF Type: DimmableLoad 305 -Load: Load60367 Added 306 -Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 3CC1 Type: DimmableLoad 307 -Load: Load15553 Added 308 -Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: F94A Type: DimmableLoad 309 -Load: Load63818 Added 310 -NETBIRDGE: NewLoads: 3 ModifiedLoads: 0 RemovedLoads: 0 311 -Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 312 -RF Gateways: 0 313 -RF Devices: 3 314 -New Loads: 6 315 -Modified Loads: 0 316 -Removed Loads: 0 317 -Zum Discovery Finished 318 -}}} 37 +Lorem 38 +)))