... ... @@ -46,7 +46,13 @@
46 46  1*. Load the Zūm Wired firmware to the ZUMNET-JBOX
47 47  1*. Repeat the above steps for all ZUMNET-JBOXs
48 48  1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step
49 -1. Connect to first ZUMNET-JBOX in the Crestron Zūm App
49 +1. Connect to each ZUMNET-JBOX in the Crestron Zūm App
50 +1*. Commission room through the app
51 +1**. configure keypad logic
52 +1**. configure occupancy sensor settings
53 +1**. calibrate photocell(s)
54 +1*. Set hostnames for the ZUMNETs.
55 +1**. Zūm discovery will bring in hostnames.
50 50  1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX
51 51  1*. If firmware was out-of-date, then this step should have already been completed
52 52  1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs