Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 23.1
edited by Alexander Mott
on 2023/12/12 18:30
on 2023/12/12 18:30
Change comment:
There is no comment for this version
To version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
on 2022/09/23 00:00
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,14 +9,6 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 - 5 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 -))) 8 - 9 9 (% class="box warningmessage" %) 10 10 ((( 11 -This article is about automatically building a S howRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 12 12 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 13 13 ))) 14 14 ... ... @@ -16,32 +16,31 @@ 16 16 {{toc/}} 17 17 {{/box}} 18 18 19 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 11 +(% class="row" %) 12 +((( 13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 20 20 21 -There are certain pre-requisites and limitations when building a S howRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.15 +There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 22 22 23 23 = Zūm Wired Discovery = 24 24 25 25 == Notes and Limitations == 26 26 27 -(% class="box warningmessage" %) 28 -((( 29 -* ShowRunnerCLC™ version 3.014 or newer required 30 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 21 +* SHOWRUNNER™ version 3.014 or newer required 22 +* Zūm Wired firmware version 1.02.10 or greater required 31 31 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 32 32 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 33 33 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 34 -))) 35 35 36 36 == Steps == 37 37 38 -1. [[Install S howRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary29 +1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 39 39 1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 40 40 1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 41 41 1*. Connect to the first ZUMNET-JBOX in Toolbox 42 42 1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 43 -1**. Note: The S howRunnerCLC™ built-in DHCP server is not meant to be used in production44 -1**. If the S howRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses34 +1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 35 +1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 45 45 1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 46 46 1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 47 47 1*. Repeat the above steps for all ZUMNET-JBOXs ... ... @@ -52,70 +52,69 @@ 52 52 1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 53 53 1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 54 54 1*. If firmware was out-of-date, then this step should have already been completed 55 -1*. Note: The S howRunnerCLC™ built-in DHCP server is not meant to be used in production56 -1*. If the S howRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses46 +1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 47 +1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 57 57 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 58 58 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 59 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 60 -1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 61 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 50 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 62 62 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 63 63 1. Run the command: ##sr discover zumnet true false## 64 -1*. This command tells ShowRunnerCLC™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 53 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 54 +1*. One area will be created per ZUMNET-JBOX 65 65 1. Run the command: ##sr discover zumnet true true## 66 -1*. This command tells ShowRunnerCLC™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 67 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 56 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 68 68 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 69 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 58 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 59 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 70 70 71 71 = Zūm Wireless Discovery = 72 72 73 73 == Notes and Limitations == 74 74 75 -(% class="box warningmessage" %) 76 -((( 77 -* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 78 -** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 65 +* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 66 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 79 79 * ZUM-NETBRIDGES must already be acquired to their respective gateway 80 -* S howRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices68 +* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 81 81 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 82 -* Plug loads will not appear in the S howRunnerCLC™ UI70 +* Plug loads will not appear in the SHOWRUNNER™ UI 83 83 ))) 84 84 85 -(% class="box in fomessage" id="HCaution:" %)73 +(% class="box warningmessage" id="HCaution:" %) 86 86 ((( 87 -**Note:** S howRunnerCLC™ has two different approaches for Zūm Wireless Discovery75 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery 88 88 89 -1. **Manual RF Gateway Assignment** - S howRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.90 -1. **Claim All RF Gateways** - S howRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network.77 +1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 78 +1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 91 91 ))) 92 92 81 +(% class="row" %) 82 +((( 93 93 == Manual RF Gateway Assignment Instructions == 94 94 95 -Use this method if you have multiple S howRunnerCLC™ instances on the same network or have gateways used by other Crestron systems.85 +Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 96 96 97 97 * Connect to the processor's console with Toolbox or your favorite SSH client. 98 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.99 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.100 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step.101 -* Type ##sr discover zummeshfalse##and press enter.88 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 89 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 90 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 91 +* Type "//sr discover zum false//" and press enter. 102 102 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 103 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process.104 -* Type ##progreset##and press enter to restart ShowRunnerCLC™105 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.93 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 94 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 95 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 106 106 * Once completed SHOWRUNNER™ is now ready for full Zūm control 107 107 108 108 == Claim All RF Gateways Instructions == 109 109 110 -Use this method when you have a single S howRunnerCLC™ instance on a local network with all gateways being used for ShowRunnerCLC™.100 +Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 111 111 112 112 * Connect to the processor's console with Toolbox or your favorite SSH client. 113 -* Type ##sr discover zummeshtrue##and press enter.103 +* Type "//sr discover zum true//" and press enter. 114 114 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 115 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process.116 -* Type ##progreset##and press enter to restart ShowRunnerCLC™117 -* Once S howRunnerCLC™ has finished restarting type##sr discover zummeshfalse##and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.118 -* Once completed S howRunnerCLC™ is now ready for full Zūm control105 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 106 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 107 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 108 +* Once completed SHOWRUNNER™ is now ready for full Zūm control 119 119 120 120 == Examples == 121 121 ... ... @@ -138,7 +138,7 @@ 138 138 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 139 139 Claimed ethernet device: CEN-GWEXER-9E6ADA 140 140 MC4>Update request from IP-ID-30 in Program 01 141 -MC4>sr discover zum meshfalse131 +MC4>sr discover zum false 142 142 Starting Zum Discovery without gateway claiming 143 143 MC4>Performing Discovery on 1 Gateways. 144 144 Evaluating 3 Devices on Gateway 30 ... ... @@ -171,7 +171,7 @@ 171 171 MC4>progreset 172 172 ... 173 173 CI ShowRunner startup completed successfully in 8072ms 174 -MC4>sr discover zum meshfalse164 +MC4>sr discover zum false 175 175 Starting Zum Discovery without gateway claiming 176 176 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 177 177 Performing Discovery on 1 Gateways. ... ... @@ -224,7 +224,7 @@ 224 224 225 225 === Claim All Example === 226 226 227 -{{{MC4>sr discover zum meshtrue217 +{{{MC4>sr discover zum true 228 228 Starting Zum Discovery with gateway claiming 229 229 MC4>Found 1 Gateways to check. 230 230 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -260,7 +260,7 @@ 260 260 MC4>progreset 261 261 ... 262 262 CI ShowRunner startup completed successfully in 8072ms 263 -MC4>sr discover zum meshfalse253 +MC4>sr discover zum false 264 264 Starting Zum Discovery without gateway claiming 265 265 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 266 266 Performing Discovery on 1 Gateways. ... ... @@ -311,3 +311,4 @@ 311 311 Removed Loads: 0 312 312 Zum Discovery Finished 313 313 }}} 304 +)))