Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Discovery1 +Zūm Autodiscovery - Content
-
... ... @@ -1,17 +12,6 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 4 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 5 -))) 6 - 7 -(% class="box errormessage" %) 8 -((( 9 -**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 10 -))) 11 - 12 12 (% class="box warningmessage" %) 13 13 ((( 14 -This article is about automatically building a S howRunnerCLC™ configuration using the ZūmDiscovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 15 15 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 16 16 ))) 17 17 ... ... @@ -19,111 +19,70 @@ 19 19 {{toc/}} 20 20 {{/box}} 21 21 22 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 11 +(% class="row" %) 12 +((( 13 +If Zūm Net devices have been configured using Crestron's Zūm App 23 23 24 - Thereare certain pre-requisites and limitationswhen building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustmentsto the final configuration, such as changing keypad types and moving loads between areas.15 += Zūm Wired = 25 25 26 - = Zūm Wired Discovery =17 +Lorem 27 27 28 -= =Notesand Limitations ==19 += Zūm Wireless = 29 29 30 -(% class="box warningmessage" %) 31 -((( 32 -* ShowRunnerCLC™ version 3.014 or newer required 33 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 34 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 35 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 36 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 37 -))) 38 38 39 -== Steps == 22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads. 23 +*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 +*Plug loads do not appear in the UI* 40 40 41 -1. [[Install ShowRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 42 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 43 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 44 -1*. Connect to the first ZUMNET-JBOX in Toolbox 45 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 46 -1**. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 47 -1**. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 48 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 49 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 50 -1*. Repeat the above steps for all ZUMNET-JBOXs 51 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 52 -1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 53 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 54 -1*. If firmware was out-of-date, then this step should have already been completed 55 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 56 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 57 -1*. If firmware was out-of-date, then this step should have already been completed 58 -1*. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 59 -1*. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 60 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 61 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 62 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 63 -1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 64 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 65 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 66 -1. Run the command: ##sr discover zumnet true false## 67 -1*. This command tells ShowRunnerCLC™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 68 -1. Run the command: ##sr discover zumnet true true## 69 -1*. This command tells ShowRunnerCLC™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 70 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 71 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 72 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 26 +== Pre-Requisites: == 73 73 74 -= Zūm Wireless Discovery = 75 - 76 -== Notes and Limitations == 77 - 78 -(% class="box warningmessage" %) 79 -((( 80 -* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 81 -** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 82 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 83 -* ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 84 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 85 -* Plug loads will not appear in the ShowRunnerCLC™ UI 28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway 30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored. 86 86 ))) 87 87 88 -(% class="box in fomessage" id="HCaution:" %)33 +(% class="box warningmessage" id="HCaution:" %) 89 89 ((( 90 -**Note:** S howRunnerCLC™ has two different approaches for Zūm WirelessDiscovery35 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery 91 91 92 -1. **Manual RF Gateway Assignment** - S howRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.93 -1. **Claim All RF Gateways** - S howRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network.37 +1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 38 +1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 94 94 ))) 95 95 96 -== Manual RF Gateway Assignment Instructions == 41 +(% class="row" %) 42 +((( 43 +== Option 1: Manual RF Gateway Claiming: == 97 97 98 -Use this method if you have multiple ShowRunner CLC™instances on the same network or have gateways used by other Crestron systems.45 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems. 99 99 100 100 * Connect to the processor's console with Toolbox or your favorite SSH client. 101 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.102 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.103 -* For each gateway that you'd like this instance of S HOWRUNNER™to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™,proceed to the next step.104 -* Type ##sr discover zummeshfalse##and press enter.105 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 106 -* When the discovery is finished type ##sr save##and press enter to save the updated config.CLC™must be restarted to complete the acquire process.107 -* Type ##progreset##and press enter to restart ShowRunnerCLC™108 -* Once S HOWRUNNER™has finished restarting type##sr discover zummeshfalse##and press enter.CLC™will be able to acquire the loads attached to the Zūm rooms at this point.109 -* Once completed S HOWRUNNER™is now ready for full Zūm control48 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 49 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 50 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step. 51 +* Type "//sr discover zum false//" and press enter. 52 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 53 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 54 +* Type "//progreset//" and press enter to restart ShowRunner 55 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 56 +* Once completed ShowRunner is now ready for full Zum control 110 110 111 -== Claim All RFGatewaysInstructions==58 +== Option 2: Claim All Gateways: == 112 112 113 -Use this method when you have a single ShowRunner CLC™instance on a local network with all gateways being used for ShowRunnerCLC™.60 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner. 114 114 115 115 * Connect to the processor's console with Toolbox or your favorite SSH client. 116 -* Type ##sr discover zummeshtrue##and press enter.117 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 118 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into,CLC™must be restarted to complete the acquire process.119 -* Type ##progreset##and press enter to restart ShowRunnerCLC™120 -* Once ShowRunner CLC™has finished restarting type##sr discover zummeshfalse##and press enter.CLC™will be able to acquire the loads attached to the Zūm rooms at this point.121 -* Once completed ShowRunner CLC™is now ready for full Zūm control63 +* Type "//sr discover zum true//" and press enter. 64 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 65 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 66 +* Type "//progreset//" and press enter to restart ShowRunner 67 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 68 +* Once completed ShowRunner is now ready for full Zum control 122 122 123 123 == Examples == 124 124 125 -=== Manual Example === 126 126 73 +=== Example for Option 1: === 74 + 127 127 {{{MC4>sr devmgr ethernet query 128 128 Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 129 129 MC4>sr devmgr ethernet show devices ... ... @@ -141,7 +141,7 @@ 141 141 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 142 142 Claimed ethernet device: CEN-GWEXER-9E6ADA 143 143 MC4>Update request from IP-ID-30 in Program 01 144 -MC4>sr discover zum meshfalse92 +MC4>sr discover zum false 145 145 Starting Zum Discovery without gateway claiming 146 146 MC4>Performing Discovery on 1 Gateways. 147 147 Evaluating 3 Devices on Gateway 30 ... ... @@ -174,7 +174,7 @@ 174 174 MC4>progreset 175 175 ... 176 176 CI ShowRunner startup completed successfully in 8072ms 177 -MC4>sr discover zum meshfalse125 +MC4>sr discover zum false 178 178 Starting Zum Discovery without gateway claiming 179 179 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 180 180 Performing Discovery on 1 Gateways. ... ... @@ -225,9 +225,9 @@ 225 225 Removed Loads: 0 226 226 Zum Discovery Finished}}} 227 227 228 -=== Claim AllExample ===176 +=== Example for Option 2: === 229 229 230 -{{{MC4>sr discover zum meshtrue178 +{{{MC4>sr discover zum true 231 231 Starting Zum Discovery with gateway claiming 232 232 MC4>Found 1 Gateways to check. 233 233 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -263,7 +263,7 @@ 263 263 MC4>progreset 264 264 ... 265 265 CI ShowRunner startup completed successfully in 8072ms 266 -MC4>sr discover zum meshfalse214 +MC4>sr discover zum false 267 267 Starting Zum Discovery without gateway claiming 268 268 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 269 269 Performing Discovery on 1 Gateways. ... ... @@ -314,3 +314,4 @@ 314 314 Removed Loads: 0 315 315 Zum Discovery Finished 316 316 }}} 265 +)))