Changes for page Zūm Discovery

Last modified by Austin Weygandt on 2025/05/02 20:21

From version 2.1
edited by Alexander Mott
on 2022/09/22 21:44
Change comment: There is no comment for this version
To version 7.1
edited by Alexander Mott
on 2022/09/22 23:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Zūm Autodiscovery
1 +Zūm Discovery
Content
... ... @@ -1,6 +1,6 @@
1 1  (% class="box warningmessage" %)
2 2  (((
3 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
4 4  For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]].
5 5  )))
6 6  
... ... @@ -10,69 +10,126 @@
10 10  
11 11  (% class="row" %)
12 12  (((
13 -If Zūm Net devices have been configured using Crestron's Zūm App
13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.
14 14  
15 -= m Wired =
15 +There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
16 16  
17 -Lorem
17 += Zūm Wired Discovery =
18 18  
19 -= Zūm Wireless =
19 +== Notes and Limitations ==
20 20  
21 +* SHOWRUNNER™ version 3.014 or newer required
22 +* Zūm Wired firmware version 1.02.10 or greater required
23 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands
24 +* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release)
25 +* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually
21 21  
22 -As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads.
23 -*Disconnect from the gateway before discovery as they cannot support multiple connections*
24 -*Plug loads do not appear in the UI*
27 +== Steps ==
25 25  
26 -== **Pre-Requisites:** ==
29 +1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary
30 +1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices.
31 +1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 
32 +1*. Connect to the first ZUMNET-JBOX in Toolbox
33 +1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
34 +1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production
35 +1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
36 +1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated
37 +1*. Load the Zūm Wired firmware to the ZUMNET-JBOX
38 +1*. Repeat the above steps for all ZUMNET-JBOXs
39 +1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, proceed to the next step
40 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App
41 +1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX
42 +1*. If firmware was out-of-date, then this step should have already been completed
43 +1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs
44 +1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
45 +1*. If firmware was out-of-date, then this step should have already been completed
46 +1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production
47 +1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
48 +1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID
49 +1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery
50 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices
51 +1. Connect to the processor in Toolbox and run the command: ##sr discover zumnet true false##
52 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration
53 +1*. One area will be created per ZUMNET-JBOX
54 +1. Run the command: ##sr discover zumnet true true##
55 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices
56 +1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware
57 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™
58 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode
27 27  
28 -* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY)
29 -* ShowRunner installed and running on a 3-series processor on the same network as the gateway
30 -* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored.
60 += Zūm Wireless Discovery =
31 31  
32 -=== **Caution:** ===
62 +== Notes and Limitations ==
33 33  
34 -* ShowRunner has 2 discovery approaches.
35 -** Option 1: Claim All RF Gateways - ShowRunner will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. DO NOT use this method if there are gateways used by different ShowRunner or other Crestron systems on the same local network.
36 -** Option 2: Manual RF Gateway Assignment - ShowRunner can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
64 +* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
65 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh##
66 +* ZUM-NETBRIDGES must already be acquired to their respective gateway
67 +* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices
68 +* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command
69 +* Plug loads will not appear in the SHOWRUNNER™ UI
70 +)))
37 37  
38 -== Option 1: Claim All Gateways: ==
72 +(% class="box warningmessage" id="HCaution:" %)
73 +(((
74 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery
39 39  
40 -Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner.
76 +1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
77 +1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.
78 +)))
41 41  
42 -* Connect to the processor's console with Toolbox or your favorite SSH client.
43 -* Type "//sr discover zum true//" and press enter.
44 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
45 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
46 -* Type "//progreset//" and press enter to restart ShowRunner
47 -* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
48 -* Once completed ShowRunner is now ready for full Zum control
80 +(% class="row" %)
81 +(((
82 +== Manual RF Gateway Assignment Instructions ==
49 49  
50 -== Option 2: Manual RF Gateway Claiming: ==
84 +Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems.
51 51  
52 -Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems.
53 -
54 54  * Connect to the processor's console with Toolbox or your favorite SSH client.
55 55  * Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways.
56 56  * Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices.
57 -* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step.
89 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.
58 58  * Type "//sr discover zum false//" and press enter.
59 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
60 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
61 -* Type "//progreset//" and press enter to restart ShowRunner
62 -* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
63 -* Once completed ShowRunner is now ready for full Zum control
91 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
92 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
93 +* Type "//progreset//" and press enter to restart SHOWRUNNER™
94 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
95 +* Once completed SHOWRUNNER™ is now ready for full Zūm control
64 64  
97 +== Claim All RF Gateways Instructions ==
98 +
99 +Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™.
100 +
101 +* Connect to the processor's console with Toolbox or your favorite SSH client.
102 +* Type "//sr discover zum true//" and press enter.
103 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
104 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
105 +* Type "//progreset//" and press enter to restart SHOWRUNNER™
106 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
107 +* Once completed SHOWRUNNER™ is now ready for full Zūm control
108 +
65 65  == Examples ==
66 66  
67 -=== Example for Option 1: ===
111 +=== Manual Example ===
68 68  
69 -{{{MC4>sr discover zum true
70 -Starting Zum Discovery with gateway claiming
71 -MC4>Found 1 Gateways to check.
72 -Claimed Gateway SN: 1720JBH04269 at IP-ID: 30
73 -Update request from IP-ID-30 in Program 01
74 -Claimed 1 Gateways. Waiting for queries to finish.
75 -Performing Discovery on 1 Gateways.
113 +{{{MC4>sr devmgr ethernet query
114 +Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess
115 +MC4>sr devmgr ethernet show devices
116 +
117 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
118 +| Adapter | Hostname | IP Address | IP-ID | ID |
119 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
120 +| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 |
121 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
122 +| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] |
123 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
124 +| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] |
125 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
126 +
127 +MC4>sr ethernet device claim CEN-GWEXER-9E6ADA
128 +Claimed ethernet device: CEN-GWEXER-9E6ADA
129 +MC4>Update request from IP-ID-30 in Program 01
130 +MC4>sr discover zum false
131 +Starting Zum Discovery without gateway claiming
132 +MC4>Performing Discovery on 1 Gateways.
76 76  Evaluating 3 Devices on Gateway 30
77 77  Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30
78 78  Dev: ZUM-NETBRIDGE addrssing to RF ID: 03
... ... @@ -83,6 +83,7 @@
83 83  Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30
84 84  Dev: ZUM-NETBRIDGE addrssing to RF ID: 05
85 85  Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05
143 +Querying cresnet
86 86  Discovering Zum Loads on 1 Gateways.
87 87  Discovering Zum Loads on 3 Devices.
88 88  NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0
... ... @@ -151,31 +151,17 @@
151 151  New Loads: 6
152 152  Modified Loads: 0
153 153  Removed Loads: 0
154 -Zum Discovery Finished
155 -}}}
212 +Zum Discovery Finished}}}
156 156  
157 -=== Example for Option 2: ===
214 +=== Claim All Example ===
158 158  
159 -{{{MC4>sr devmgr ethernet query
160 -Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess
161 -MC4>sr devmgr ethernet show devices
162 -
163 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
164 -| Adapter | Hostname | IP Address | IP-ID | ID |
165 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
166 -| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 |
167 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
168 -| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] |
169 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
170 -| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] |
171 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
172 -
173 -MC4>sr ethernet device claim CEN-GWEXER-9E6ADA
174 -Claimed ethernet device: CEN-GWEXER-9E6ADA
175 -MC4>Update request from IP-ID-30 in Program 01
176 -MC4>sr discover zum false
177 -Starting Zum Discovery without gateway claiming
178 -MC4>Performing Discovery on 1 Gateways.
216 +{{{MC4>sr discover zum true
217 +Starting Zum Discovery with gateway claiming
218 +MC4>Found 1 Gateways to check.
219 +Claimed Gateway SN: 1720JBH04269 at IP-ID: 30
220 +Update request from IP-ID-30 in Program 01
221 +Claimed 1 Gateways. Waiting for queries to finish.
222 +Performing Discovery on 1 Gateways.
179 179  Evaluating 3 Devices on Gateway 30
180 180  Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30
181 181  Dev: ZUM-NETBRIDGE addrssing to RF ID: 03
... ... @@ -186,7 +186,6 @@
186 186  Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30
187 187  Dev: ZUM-NETBRIDGE addrssing to RF ID: 05
188 188  Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05
189 -Querying cresnet
190 190  Discovering Zum Loads on 1 Gateways.
191 191  Discovering Zum Loads on 3 Devices.
192 192  NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0
... ... @@ -256,5 +256,5 @@
256 256  Modified Loads: 0
257 257  Removed Loads: 0
258 258  Zum Discovery Finished
259 - }}}
302 +}}}
260 260  )))