Changes for page Zūm Discovery

Last modified by Alexander Mott on 2025/04/03 17:35

From version 18.1
edited by Alexander Mott
on 2023/04/20 18:39
Change comment: There is no comment for this version
To version 10.1
edited by Alexander Mott
on 2022/10/05 16:18
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,10 +8,3 @@
1 -(% class="box errormessage" %)
2 -(((
3 -WARNING: Cresnet Discovery is not currently working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE.
4 -
5 -Downgrade SHOWRUNNER™ to v3.018 in order to auto-discover hardware. SHOWRUNNER™ can be subsequently upgraded once discovery is complete.
6 -)))
7 -
8 8  (% class="box warningmessage" %)
9 9  (((
10 10  This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
... ... @@ -15,6 +15,8 @@
15 15  {{toc/}}
16 16  {{/box}}
17 17  
11 +(% class="row" %)
12 +(((
18 18  If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.
19 19  
20 20  There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
... ... @@ -23,10 +23,10 @@
23 23  
24 24  == Notes and Limitations ==
25 25  
26 -(% class="box warningmessage" %)
21 +(% class="box errormessage" %)
27 27  (((
28 28  * SHOWRUNNER™ version 3.014 or newer required
29 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081)
24 +* Zūm Wired firmware version 1.02.10 or greater required
30 30  * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands
31 31  * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release)
32 32  * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually
... ... @@ -55,23 +55,22 @@
55 55  1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
56 56  1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID
57 57  1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery
58 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program
59 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode
60 60  1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices
61 61  1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox
62 62  1. Run the command: ##sr discover zumnet true false##
63 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration
56 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration
57 +1*. One area will be created per ZUMNET-JBOX
64 64  1. Run the command: ##sr discover zumnet true true##
65 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration
66 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area
59 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices
67 67  1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware
68 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly.
61 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™
62 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode
69 69  
70 70  = Zūm Wireless Discovery =
71 71  
72 72  == Notes and Limitations ==
73 73  
74 -(% class="box warningmessage" %)
68 +(% class="box errormessage" %)
75 75  (((
76 76  * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
77 77  ** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##**
... ... @@ -81,7 +81,7 @@
81 81  * Plug loads will not appear in the SHOWRUNNER™ UI
82 82  )))
83 83  
84 -(% class="box infomessage" id="HCaution:" %)
78 +(% class="box warningmessage" id="HCaution:" %)
85 85  (((
86 86  **Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery
87 87  
... ... @@ -310,3 +310,4 @@
310 310  Removed Loads: 0
311 311  Zum Discovery Finished
312 312  }}}
307 +)))