Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 18.1
edited by Alexander Mott
on 2023/04/20 18:39
on 2023/04/20 18:39
Change comment:
There is no comment for this version
To version 10.1
edited by Alexander Mott
on 2022/10/05 16:18
on 2022/10/05 16:18
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +8,3 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -WARNING: Cresnet Discovery is not currently working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. 4 - 5 -Downgrade SHOWRUNNER™ to v3.018 in order to auto-discover hardware. SHOWRUNNER™ can be subsequently upgraded once discovery is complete. 6 -))) 7 - 8 8 (% class="box warningmessage" %) 9 9 ((( 10 10 This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. ... ... @@ -15,6 +15,8 @@ 15 15 {{toc/}} 16 16 {{/box}} 17 17 11 +(% class="row" %) 12 +((( 18 18 If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 19 19 20 20 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. ... ... @@ -23,10 +23,10 @@ 23 23 24 24 == Notes and Limitations == 25 25 26 -(% class="box warningmessage" %)21 +(% class="box errormessage" %) 27 27 ((( 28 28 * SHOWRUNNER™ version 3.014 or newer required 29 -* Zūm Wired firmware .pufversion 1.02.10 or greater required(ZUMNET-JBOX installed minimum version 1.001.00081)24 +* Zūm Wired firmware version 1.02.10 or greater required 30 30 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 31 31 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 32 32 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually ... ... @@ -55,23 +55,22 @@ 55 55 1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 56 56 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 57 57 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 58 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 59 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 60 60 1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 61 61 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 62 62 1. Run the command: ##sr discover zumnet true false## 63 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 56 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 57 +1*. One area will be created per ZUMNET-JBOX 64 64 1. Run the command: ##sr discover zumnet true true## 65 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 66 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 59 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 67 67 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 68 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 61 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 62 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 69 69 70 70 = Zūm Wireless Discovery = 71 71 72 72 == Notes and Limitations == 73 73 74 -(% class="box warningmessage" %)68 +(% class="box errormessage" %) 75 75 ((( 76 76 * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 77 77 ** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** ... ... @@ -81,7 +81,7 @@ 81 81 * Plug loads will not appear in the SHOWRUNNER™ UI 82 82 ))) 83 83 84 -(% class="box in fomessage" id="HCaution:" %)78 +(% class="box warningmessage" id="HCaution:" %) 85 85 ((( 86 86 **Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery 87 87 ... ... @@ -310,3 +310,4 @@ 310 310 Removed Loads: 0 311 311 Zum Discovery Finished 312 312 }}} 307 +)))