Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 16.1
edited by Alexander Mott
on 2023/03/29 21:19
on 2023/03/29 21:19
Change comment:
There is no comment for this version
To version 9.1
edited by Alexander Mott
on 2022/10/05 16:17
on 2022/10/05 16:17
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +6,3 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -WARNING: Cresnet Discovery is not currently working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before SHOWRUNNER™ can auto-discover hardware. 4 -))) 5 - 6 6 (% class="box warningmessage" %) 7 7 ((( 8 8 This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. ... ... @@ -13,6 +13,8 @@ 13 13 {{toc/}} 14 14 {{/box}} 15 15 11 +(% class="row" %) 12 +((( 16 16 If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 17 17 18 18 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. ... ... @@ -21,10 +21,10 @@ 21 21 22 22 == Notes and Limitations == 23 23 24 -(% class="box warningmessage" %)21 +(% class="box errormessage" %) 25 25 ((( 26 26 * SHOWRUNNER™ version 3.014 or newer required 27 -* Zūm Wired firmware .pufversion 1.02.10 or greater required(ZUMNET-JBOX installed minimum version 1.001.00081)24 +* Zūm Wired firmware version 1.02.10 or greater required 28 28 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 29 29 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 30 30 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually ... ... @@ -53,21 +53,21 @@ 53 53 1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 54 54 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 55 55 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 56 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 57 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 58 58 1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 59 59 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 60 60 1. Run the command: ##sr discover zumnet true false## 61 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 56 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 57 +1*. One area will be created per ZUMNET-JBOX 62 62 1. Run the command: ##sr discover zumnet true true## 63 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 64 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 59 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 65 65 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 66 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 61 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 62 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 67 67 68 68 = Zūm Wireless Discovery = 69 69 70 70 == Notes and Limitations == 67 +))) 71 71 72 72 (% class="box errormessage" %) 73 73 ((( ... ... @@ -87,6 +87,8 @@ 87 87 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 88 88 ))) 89 89 87 +(% class="row" %) 88 +((( 90 90 == Manual RF Gateway Assignment Instructions == 91 91 92 92 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. ... ... @@ -308,3 +308,4 @@ 308 308 Removed Loads: 0 309 309 Zum Discovery Finished 310 310 }}} 310 +)))