Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 16.1
edited by Alexander Mott
on 2023/03/29 21:19
on 2023/03/29 21:19
Change comment:
There is no comment for this version
To version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
on 2022/09/23 00:00
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +6,3 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -WARNING: Cresnet Discovery is not currently working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before SHOWRUNNER™ can auto-discover hardware. 4 -))) 5 - 6 6 (% class="box warningmessage" %) 7 7 ((( 8 8 This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. ... ... @@ -13,6 +13,8 @@ 13 13 {{toc/}} 14 14 {{/box}} 15 15 11 +(% class="row" %) 12 +((( 16 16 If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 17 17 18 18 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. ... ... @@ -21,14 +21,11 @@ 21 21 22 22 == Notes and Limitations == 23 23 24 -(% class="box warningmessage" %) 25 -((( 26 26 * SHOWRUNNER™ version 3.014 or newer required 27 -* Zūm Wired firmware .pufversion 1.02.10 or greater required(ZUMNET-JBOX installed minimum version 1.001.00081)22 +* Zūm Wired firmware version 1.02.10 or greater required 28 28 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 29 29 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 30 30 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 31 -))) 32 32 33 33 == Steps == 34 34 ... ... @@ -53,26 +53,23 @@ 53 53 1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 54 54 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 55 55 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 56 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 57 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 58 58 1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 59 59 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 60 60 1. Run the command: ##sr discover zumnet true false## 61 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 53 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 54 +1*. One area will be created per ZUMNET-JBOX 62 62 1. Run the command: ##sr discover zumnet true true## 63 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 64 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 56 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 65 65 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 66 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 58 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 59 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 67 67 68 68 = Zūm Wireless Discovery = 69 69 70 70 == Notes and Limitations == 71 71 72 -(% class="box errormessage" %) 73 -((( 74 74 * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 75 -** For SHOWRUNNER™ versions prior to3.014 and newer, replace**##sr discover zummesh##**commands with**##sr discover zum##**66 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 76 76 * ZUM-NETBRIDGES must already be acquired to their respective gateway 77 77 * SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 78 78 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command ... ... @@ -87,19 +87,21 @@ 87 87 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 88 88 ))) 89 89 81 +(% class="row" %) 82 +((( 90 90 == Manual RF Gateway Assignment Instructions == 91 91 92 92 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 93 93 94 94 * Connect to the processor's console with Toolbox or your favorite SSH client. 95 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.96 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.97 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.98 -* Type ##sr discover zummeshfalse##and press enter.88 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 89 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 90 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 91 +* Type "//sr discover zum false//" and press enter. 99 99 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 100 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.101 -* Type ##progreset##and press enter to restart SHOWRUNNER™102 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.93 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 94 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 95 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 103 103 * Once completed SHOWRUNNER™ is now ready for full Zūm control 104 104 105 105 == Claim All RF Gateways Instructions == ... ... @@ -107,11 +107,11 @@ 107 107 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 108 108 109 109 * Connect to the processor's console with Toolbox or your favorite SSH client. 110 -* Type ##sr discover zummeshtrue##and press enter.103 +* Type "//sr discover zum true//" and press enter. 111 111 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 112 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.113 -* Type ##progreset##and press enter to restart SHOWRUNNER™114 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.105 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 106 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 107 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 115 115 * Once completed SHOWRUNNER™ is now ready for full Zūm control 116 116 117 117 == Examples == ... ... @@ -135,7 +135,7 @@ 135 135 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 136 136 Claimed ethernet device: CEN-GWEXER-9E6ADA 137 137 MC4>Update request from IP-ID-30 in Program 01 138 -MC4>sr discover zum meshfalse131 +MC4>sr discover zum false 139 139 Starting Zum Discovery without gateway claiming 140 140 MC4>Performing Discovery on 1 Gateways. 141 141 Evaluating 3 Devices on Gateway 30 ... ... @@ -168,7 +168,7 @@ 168 168 MC4>progreset 169 169 ... 170 170 CI ShowRunner startup completed successfully in 8072ms 171 -MC4>sr discover zum meshfalse164 +MC4>sr discover zum false 172 172 Starting Zum Discovery without gateway claiming 173 173 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 174 174 Performing Discovery on 1 Gateways. ... ... @@ -221,7 +221,7 @@ 221 221 222 222 === Claim All Example === 223 223 224 -{{{MC4>sr discover zum meshtrue217 +{{{MC4>sr discover zum true 225 225 Starting Zum Discovery with gateway claiming 226 226 MC4>Found 1 Gateways to check. 227 227 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -257,7 +257,7 @@ 257 257 MC4>progreset 258 258 ... 259 259 CI ShowRunner startup completed successfully in 8072ms 260 -MC4>sr discover zum meshfalse253 +MC4>sr discover zum false 261 261 Starting Zum Discovery without gateway claiming 262 262 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 263 263 Performing Discovery on 1 Gateways. ... ... @@ -308,3 +308,4 @@ 308 308 Removed Loads: 0 309 309 Zum Discovery Finished 310 310 }}} 304 +)))