Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 16.1
edited by Alexander Mott
on 2023/03/29 21:19
on 2023/03/29 21:19
Change comment:
There is no comment for this version
To version 5.2
edited by Alexander Mott
on 2022/09/22 22:11
on 2022/09/22 22:11
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +6,3 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -WARNING: Cresnet Discovery is not currently working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before SHOWRUNNER™ can auto-discover hardware. 4 -))) 5 - 6 6 (% class="box warningmessage" %) 7 7 ((( 8 8 This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. ... ... @@ -13,105 +13,68 @@ 13 13 {{toc/}} 14 14 {{/box}} 15 15 16 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 11 +(% class="row" %) 12 +((( 13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Autodiscovery feature that is built into SHOWRUNNER™. 17 17 18 18 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 19 19 20 20 = Zūm Wired Discovery = 21 21 22 - == Notes and Limitations ==19 +Lorem 23 23 24 -(% class="box warningmessage" %) 25 -((( 26 -* SHOWRUNNER™ version 3.014 or newer required 27 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 28 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 29 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 30 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 31 -))) 21 += Zūm Wireless Discovery = 32 32 33 -== Steps == 23 +*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 +*Plug loads do not appear in the UI* 34 34 35 -1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 36 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 37 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 38 -1*. Connect to the first ZUMNET-JBOX in Toolbox 39 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 40 -1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 41 -1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 42 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 43 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 44 -1*. Repeat the above steps for all ZUMNET-JBOXs 45 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 46 -1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 47 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 48 -1*. If firmware was out-of-date, then this step should have already been completed 49 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 50 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 51 -1*. If firmware was out-of-date, then this step should have already been completed 52 -1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 53 -1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 54 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 55 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 56 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 57 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 58 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 59 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 60 -1. Run the command: ##sr discover zumnet true false## 61 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 62 -1. Run the command: ##sr discover zumnet true true## 63 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 64 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 65 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 66 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 26 +== Notes and Limitations == 67 67 68 -= Zūm Wireless Discovery = 28 +* SHOWRUNNER™ version 2.190 or newer required 29 +* Disconnect from any RF gateways you are connected to prior to running the autodiscovery command, 69 69 70 -== Notesand Limitations ==31 +== Pre-Requisites == 71 71 72 -(% class="box errormessage" %) 73 -((( 74 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 75 -** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 76 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 77 -* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 78 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 79 -* Plug loads will not appear in the SHOWRUNNER™ UI 33 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 34 +* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway 35 +* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored. 80 80 ))) 81 81 82 82 (% class="box warningmessage" id="HCaution:" %) 83 83 ((( 84 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery40 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery 85 85 86 86 1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 87 87 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 88 88 ))) 89 89 90 -== Manual RF Gateway Assignment Instructions == 46 +(% class="row" %) 47 +((( 48 +== Manual RF Gateway Assignment == 91 91 92 92 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 93 93 94 94 * Connect to the processor's console with Toolbox or your favorite SSH client. 95 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.96 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.97 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.98 -* Type ##sr discover zummeshfalse##and press enter.53 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 54 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 55 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 56 +* Type "//sr discover zum false//" and press enter. 99 99 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 100 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.101 -* Type ##progreset##and press enter to restart SHOWRUNNER™102 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.58 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 59 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 60 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 103 103 * Once completed SHOWRUNNER™ is now ready for full Zūm control 104 104 105 -== Claim All RF Gateways Instructions==63 +== Claim All RF Gateways == 106 106 107 107 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 108 108 109 109 * Connect to the processor's console with Toolbox or your favorite SSH client. 110 -* Type ##sr discover zummeshtrue##and press enter.68 +* Type "//sr discover zum true//" and press enter. 111 111 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 112 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.113 -* Type ##progreset##and press enter to restart SHOWRUNNER™114 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.70 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 71 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 72 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 115 115 * Once completed SHOWRUNNER™ is now ready for full Zūm control 116 116 117 117 == Examples == ... ... @@ -135,7 +135,7 @@ 135 135 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 136 136 Claimed ethernet device: CEN-GWEXER-9E6ADA 137 137 MC4>Update request from IP-ID-30 in Program 01 138 -MC4>sr discover zum meshfalse96 +MC4>sr discover zum false 139 139 Starting Zum Discovery without gateway claiming 140 140 MC4>Performing Discovery on 1 Gateways. 141 141 Evaluating 3 Devices on Gateway 30 ... ... @@ -168,7 +168,7 @@ 168 168 MC4>progreset 169 169 ... 170 170 CI ShowRunner startup completed successfully in 8072ms 171 -MC4>sr discover zum meshfalse129 +MC4>sr discover zum false 172 172 Starting Zum Discovery without gateway claiming 173 173 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 174 174 Performing Discovery on 1 Gateways. ... ... @@ -221,7 +221,7 @@ 221 221 222 222 === Claim All Example === 223 223 224 -{{{MC4>sr discover zum meshtrue182 +{{{MC4>sr discover zum true 225 225 Starting Zum Discovery with gateway claiming 226 226 MC4>Found 1 Gateways to check. 227 227 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -257,7 +257,7 @@ 257 257 MC4>progreset 258 258 ... 259 259 CI ShowRunner startup completed successfully in 8072ms 260 -MC4>sr discover zum meshfalse218 +MC4>sr discover zum false 261 261 Starting Zum Discovery without gateway claiming 262 262 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 263 263 Performing Discovery on 1 Gateways. ... ... @@ -308,3 +308,4 @@ 308 308 Removed Loads: 0 309 309 Zum Discovery Finished 310 310 }}} 269 +)))