Changes for page Zūm Discovery

Last modified by Austin Weygandt on 2025/05/02 20:21

From version 16.1
edited by Alexander Mott
on 2023/03/29 21:19
Change comment: There is no comment for this version
To version 4.1
edited by Alexander Mott
on 2022/09/22 21:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Zūm Discovery
1 +Zūm Autodiscovery
Content
... ... @@ -1,11 +6,6 @@
1 -(% class="box errormessage" %)
2 -(((
3 -WARNING: Cresnet Discovery is not currently working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before SHOWRUNNER™ can auto-discover hardware.
4 -)))
5 -
6 6  (% class="box warningmessage" %)
7 7  (((
8 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
9 9  For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]].
10 10  )))
11 11  
... ... @@ -13,111 +13,70 @@
13 13  {{toc/}}
14 14  {{/box}}
15 15  
16 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.
11 +(% class="row" %)
12 +(((
13 +If Zūm Net devices have been configured using Crestron's Zūm App
17 17  
18 -There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
15 += m Wired =
19 19  
20 -= Zūm Wired Discovery =
17 +Lorem
21 21  
22 -== Notes and Limitations ==
19 += Zūm Wireless =
23 23  
24 -(% class="box warningmessage" %)
25 -(((
26 -* SHOWRUNNER™ version 3.014 or newer required
27 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081)
28 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands
29 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release)
30 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually
31 -)))
32 32  
33 -== Steps ==
22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads.
23 +*Disconnect from the gateway before discovery as they cannot support multiple connections*
24 +*Plug loads do not appear in the UI*
34 34  
35 -1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary
36 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices.
37 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 
38 -1*. Connect to the first ZUMNET-JBOX in Toolbox
39 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
40 -1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production
41 -1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
42 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated
43 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX
44 -1*. Repeat the above steps for all ZUMNET-JBOXs
45 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step
46 -1. Connect to first ZUMNET-JBOX in the Crestron Zūm App
47 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX
48 -1*. If firmware was out-of-date, then this step should have already been completed
49 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs
50 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
51 -1*. If firmware was out-of-date, then this step should have already been completed
52 -1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production
53 -1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
54 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID
55 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery
56 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program
57 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode
58 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices
59 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox
60 -1. Run the command: ##sr discover zumnet true false##
61 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration
62 -1. Run the command: ##sr discover zumnet true true##
63 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration
64 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area
65 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware
66 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly.
26 +== Pre-Requisites: ==
67 67  
68 -= Zūm Wireless Discovery =
69 -
70 -== Notes and Limitations ==
71 -
72 -(% class="box errormessage" %)
73 -(((
74 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
75 -** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##**
76 -* ZUM-NETBRIDGES must already be acquired to their respective gateway
77 -* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices
78 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command
79 -* Plug loads will not appear in the SHOWRUNNER™ UI
28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY)
29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway
30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored.
80 80  )))
81 81  
82 82  (% class="box warningmessage" id="HCaution:" %)
83 83  (((
84 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery
35 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery
85 85  
86 86  1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
87 87  1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.
88 88  )))
89 89  
90 -== Manual RF Gateway Assignment Instructions ==
41 +(% class="row" %)
42 +(((
43 +== Option 1: Manual RF Gateway Claiming: ==
91 91  
92 -Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems.
45 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems.
93 93  
94 94  * Connect to the processor's console with Toolbox or your favorite SSH client.
95 -* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways.
96 -* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices.
97 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.
98 -* Type ##sr discover zummesh false## and press enter.
99 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
100 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
101 -* Type ##progreset## and press enter to restart SHOWRUNNER™
102 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
103 -* Once completed SHOWRUNNER™ is now ready for full Zūm control
48 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways.
49 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices.
50 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step.
51 +* Type "//sr discover zum false//" and press enter.
52 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
53 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
54 +* Type "//progreset//" and press enter to restart ShowRunner
55 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
56 +* Once completed ShowRunner is now ready for full Zum control
104 104  
105 -== Claim All RF Gateways Instructions ==
58 +== Option 2: Claim All Gateways: ==
106 106  
107 -Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™.
60 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner.
108 108  
109 109  * Connect to the processor's console with Toolbox or your favorite SSH client.
110 -* Type ##sr discover zummesh true## and press enter.
111 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
112 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
113 -* Type ##progreset## and press enter to restart SHOWRUNNER™
114 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
115 -* Once completed SHOWRUNNER™ is now ready for full Zūm control
63 +* Type "//sr discover zum true//" and press enter.
64 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
65 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
66 +* Type "//progreset//" and press enter to restart ShowRunner
67 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
68 +* Once completed ShowRunner is now ready for full Zum control
116 116  
117 117  == Examples ==
118 118  
119 -=== Manual Example ===
120 120  
73 +=== Example for Option 1: ===
74 +
121 121  {{{MC4>sr devmgr ethernet query
122 122  Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess
123 123  MC4>sr devmgr ethernet show devices
... ... @@ -135,7 +135,7 @@
135 135  MC4>sr ethernet device claim CEN-GWEXER-9E6ADA
136 136  Claimed ethernet device: CEN-GWEXER-9E6ADA
137 137  MC4>Update request from IP-ID-30 in Program 01
138 -MC4>sr discover zummesh false
92 +MC4>sr discover zum false
139 139  Starting Zum Discovery without gateway claiming
140 140  MC4>Performing Discovery on 1 Gateways.
141 141  Evaluating 3 Devices on Gateway 30
... ... @@ -168,7 +168,7 @@
168 168  MC4>progreset
169 169  ...
170 170  CI ShowRunner startup completed successfully in 8072ms
171 -MC4>sr discover zummesh false
125 +MC4>sr discover zum false
172 172  Starting Zum Discovery without gateway claiming
173 173  MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable)
174 174  Performing Discovery on 1 Gateways.
... ... @@ -219,9 +219,9 @@
219 219  Removed Loads: 0
220 220  Zum Discovery Finished}}}
221 221  
222 -=== Claim All Example ===
176 +=== Example for Option 2: ===
223 223  
224 -{{{MC4>sr discover zummesh true
178 +{{{MC4>sr discover zum true
225 225  Starting Zum Discovery with gateway claiming
226 226  MC4>Found 1 Gateways to check.
227 227  Claimed Gateway SN: 1720JBH04269 at IP-ID: 30
... ... @@ -257,7 +257,7 @@
257 257  MC4>progreset
258 258  ...
259 259  CI ShowRunner startup completed successfully in 8072ms
260 -MC4>sr discover zummesh false
214 +MC4>sr discover zum false
261 261  Starting Zum Discovery without gateway claiming
262 262  MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable)
263 263  Performing Discovery on 1 Gateways.
... ... @@ -308,3 +308,4 @@
308 308  Removed Loads: 0
309 309  Zum Discovery Finished
310 310  }}}
265 +)))