Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 15.1
edited by Alexander Mott
on 2023/03/29 21:00
on 2023/03/29 21:00
Change comment:
There is no comment for this version
To version 3.1
edited by Alexander Mott
on 2022/09/22 21:47
on 2022/09/22 21:47
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Discovery1 +Zūm Autodiscovery - Content
-
... ... @@ -1,10 +5,6 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before SHOWRUNNER™ can auto-discover hardware. 4 -))) 5 5 (% class="box warningmessage" %) 6 6 ((( 7 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 8 8 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 9 9 ))) 10 10 ... ... @@ -12,131 +12,72 @@ 12 12 {{toc/}} 13 13 {{/box}} 14 14 15 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 11 +(% class="row" %) 12 +((( 13 +If Zūm Net devices have been configured using Crestron's Zūm App 16 16 17 - Thereare certain pre-requisites and limitationswhen building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustmentsto the final configuration, such as changing keypad types and moving loads between areas.15 += Zūm Wired = 18 18 19 - = Zūm Wired Discovery =17 +Lorem 20 20 21 -= =Notesand Limitations ==19 += Zūm Wireless = 22 22 23 -(% class="box warningmessage" %) 24 -((( 25 -* SHOWRUNNER™ version 3.014 or newer required 26 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 27 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 28 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 29 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 30 -))) 31 31 32 -== Steps == 22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads. 23 +*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 +*Plug loads do not appear in the UI* 33 33 34 -1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 35 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 36 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 37 -1*. Connect to the first ZUMNET-JBOX in Toolbox 38 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 39 -1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 40 -1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 41 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 42 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 43 -1*. Repeat the above steps for all ZUMNET-JBOXs 44 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 45 -1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 46 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 47 -1*. If firmware was out-of-date, then this step should have already been completed 48 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 49 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 50 -1*. If firmware was out-of-date, then this step should have already been completed 51 -1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 52 -1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 53 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 54 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 55 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 56 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 57 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 58 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 59 -1. Run the command: ##sr discover zumnet true false## 60 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 61 -1. Run the command: ##sr discover zumnet true true## 62 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 63 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 64 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 65 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 26 +== Pre-Requisites: == 66 66 67 -= Zūm Wireless Discovery = 28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway 30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored. 68 68 69 -== Notes and Limitations == 70 - 71 -(% class="box errormessage" %) 72 -((( 73 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 74 -** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 75 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 76 -* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 77 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 78 -* Plug loads will not appear in the SHOWRUNNER™ UI 79 -))) 80 - 81 81 (% class="box warningmessage" id="HCaution:" %) 82 82 ((( 83 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery 84 - 85 -1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 86 -1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 34 +**Note,** SHOWRUNNER has two different types of Zum Wireless autodiscovery: 35 +1. Claim All RF Gateways - ShowRunner will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. DO NOT use this method if there are gateways used by different ShowRunner or other Crestron systems on the same local network. 36 +1. Manual RF Gateway Assignment - ShowRunner can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 87 87 ))) 88 88 89 -== ManualRFGatewayAssignmentInstructions==39 +== Option 1: Claim All Gateways: == 90 90 91 -Use this method ifyou havemultiple SHOWRUNNER™instancesonthesamenetworkorhavegateways usedbyotherCrestronsystems.41 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner. 92 92 93 93 * Connect to the processor's console with Toolbox or your favorite SSH client. 94 -* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways. 95 -* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices. 96 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 97 -* Type ##sr discover zummesh false## and press enter. 98 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 99 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 100 -* Type ##progreset## and press enter to restart SHOWRUNNER™ 101 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 102 -* Once completed SHOWRUNNER™ is now ready for full Zūm control 44 +* Type "//sr discover zum true//" and press enter. 45 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 46 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 47 +* Type "//progreset//" and press enter to restart ShowRunner 48 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 49 +* Once completed ShowRunner is now ready for full Zum control 103 103 104 -== ClaimAllRF GatewaysInstructions==51 +== Option 2: Manual RF Gateway Claiming: == 105 105 106 -Use this method whenyou havea single SHOWRUNNER™instance onalocalnetworkwithallgatewaysbeingusedforSHOWRUNNER™.53 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems. 107 107 108 108 * Connect to the processor's console with Toolbox or your favorite SSH client. 109 -* Type ##sr discover zummesh true## and press enter. 110 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 111 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 112 -* Type ##progreset## and press enter to restart SHOWRUNNER™ 113 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 114 -* Once completed SHOWRUNNER™ is now ready for full Zūm control 56 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 57 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 58 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step. 59 +* Type "//sr discover zum false//" and press enter. 60 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 61 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 62 +* Type "//progreset//" and press enter to restart ShowRunner 63 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 64 +* Once completed ShowRunner is now ready for full Zum control 115 115 116 116 == Examples == 117 117 118 -=== ManualExample ===68 +=== Example for Option 1: === 119 119 120 -{{{MC4>sr devmgr ethernet query 121 -Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 122 -MC4>sr devmgr ethernet show devices 123 - 124 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 125 -| Adapter | Hostname | IP Address | IP-ID | ID | 126 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 127 -| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 | 128 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 129 -| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] | 130 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 131 -| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] | 132 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 133 - 134 -MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 135 -Claimed ethernet device: CEN-GWEXER-9E6ADA 136 -MC4>Update request from IP-ID-30 in Program 01 137 -MC4>sr discover zummesh false 138 -Starting Zum Discovery without gateway claiming 139 -MC4>Performing Discovery on 1 Gateways. 70 +{{{MC4>sr discover zum true 71 +Starting Zum Discovery with gateway claiming 72 +MC4>Found 1 Gateways to check. 73 +Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 74 +Update request from IP-ID-30 in Program 01 75 +Claimed 1 Gateways. Waiting for queries to finish. 76 +Performing Discovery on 1 Gateways. 140 140 Evaluating 3 Devices on Gateway 30 141 141 Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 142 142 Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 ... ... @@ -147,7 +147,6 @@ 147 147 Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 148 148 Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 149 149 Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 150 -Querying cresnet 151 151 Discovering Zum Loads on 1 Gateways. 152 152 Discovering Zum Loads on 3 Devices. 153 153 NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 ... ... @@ -167,7 +167,7 @@ 167 167 MC4>progreset 168 168 ... 169 169 CI ShowRunner startup completed successfully in 8072ms 170 -MC4>sr discover zum meshfalse106 +MC4>sr discover zum false 171 171 Starting Zum Discovery without gateway claiming 172 172 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 173 173 Performing Discovery on 1 Gateways. ... ... @@ -216,17 +216,31 @@ 216 216 New Loads: 6 217 217 Modified Loads: 0 218 218 Removed Loads: 0 219 -Zum Discovery Finished}}} 155 +Zum Discovery Finished 156 +}}} 220 220 221 -=== Claim AllExample ===158 +=== Example for Option 2: === 222 222 223 -{{{MC4>sr discover zummesh true 224 -Starting Zum Discovery with gateway claiming 225 -MC4>Found 1 Gateways to check. 226 -Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 227 -Update request from IP-ID-30 in Program 01 228 -Claimed 1 Gateways. Waiting for queries to finish. 229 -Performing Discovery on 1 Gateways. 160 +{{{MC4>sr devmgr ethernet query 161 +Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 162 +MC4>sr devmgr ethernet show devices 163 + 164 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 165 +| Adapter | Hostname | IP Address | IP-ID | ID | 166 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 167 +| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 | 168 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 169 +| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] | 170 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 171 +| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] | 172 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 173 + 174 +MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 175 +Claimed ethernet device: CEN-GWEXER-9E6ADA 176 +MC4>Update request from IP-ID-30 in Program 01 177 +MC4>sr discover zum false 178 +Starting Zum Discovery without gateway claiming 179 +MC4>Performing Discovery on 1 Gateways. 230 230 Evaluating 3 Devices on Gateway 30 231 231 Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 232 232 Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 ... ... @@ -237,6 +237,7 @@ 237 237 Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 238 238 Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 239 239 Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 190 +Querying cresnet 240 240 Discovering Zum Loads on 1 Gateways. 241 241 Discovering Zum Loads on 3 Devices. 242 242 NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 ... ... @@ -256,7 +256,7 @@ 256 256 MC4>progreset 257 257 ... 258 258 CI ShowRunner startup completed successfully in 8072ms 259 -MC4>sr discover zum meshfalse210 +MC4>sr discover zum false 260 260 Starting Zum Discovery without gateway claiming 261 261 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 262 262 Performing Discovery on 1 Gateways. ... ... @@ -306,4 +306,5 @@ 306 306 Modified Loads: 0 307 307 Removed Loads: 0 308 308 Zum Discovery Finished 309 -}}} 260 + }}} 261 +)))