Changes for page Zūm Discovery

Last modified by Alexander Mott on 2025/04/03 17:35

From version 15.1
edited by Alexander Mott
on 2023/03/29 21:00
Change comment: There is no comment for this version
To version 11.1
edited by Alexander Mott
on 2022/10/05 16:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +5,3 @@
1 -(% class="box errormessage" %)
2 -(((
3 -Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before SHOWRUNNER™ can auto-discover hardware.
4 -)))
5 5  (% class="box warningmessage" %)
6 6  (((
7 7  This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
... ... @@ -20,10 +20,10 @@
20 20  
21 21  == Notes and Limitations ==
22 22  
23 -(% class="box warningmessage" %)
19 +(% class="box errormessage" %)
24 24  (((
25 25  * SHOWRUNNER™ version 3.014 or newer required
26 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081)
22 +* Zūm Wired firmware version 1.02.10 or greater required
27 27  * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands
28 28  * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release)
29 29  * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually
... ... @@ -52,17 +52,16 @@
52 52  1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
53 53  1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID
54 54  1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery
55 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program
56 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode
57 57  1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices
58 58  1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox
59 59  1. Run the command: ##sr discover zumnet true false##
60 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration
54 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration
55 +1*. One area will be created per ZUMNET-JBOX
61 61  1. Run the command: ##sr discover zumnet true true##
62 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration
63 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area
57 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices
64 64  1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware
65 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly.
59 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™
60 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode
66 66  
67 67  = Zūm Wireless Discovery =
68 68