Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 15.1
edited by Alexander Mott
on 2023/03/29 21:00
on 2023/03/29 21:00
Change comment:
There is no comment for this version
To version 11.1
edited by Alexander Mott
on 2022/10/05 16:19
on 2022/10/05 16:19
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +5,3 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before SHOWRUNNER™ can auto-discover hardware. 4 -))) 5 5 (% class="box warningmessage" %) 6 6 ((( 7 7 This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. ... ... @@ -20,10 +20,10 @@ 20 20 21 21 == Notes and Limitations == 22 22 23 -(% class="box warningmessage" %)19 +(% class="box errormessage" %) 24 24 ((( 25 25 * SHOWRUNNER™ version 3.014 or newer required 26 -* Zūm Wired firmware .pufversion 1.02.10 or greater required(ZUMNET-JBOX installed minimum version 1.001.00081)22 +* Zūm Wired firmware version 1.02.10 or greater required 27 27 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 28 28 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 29 29 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually ... ... @@ -52,17 +52,16 @@ 52 52 1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 53 53 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 54 54 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 55 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 56 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 57 57 1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 58 58 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 59 59 1. Run the command: ##sr discover zumnet true false## 60 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 54 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 55 +1*. One area will be created per ZUMNET-JBOX 61 61 1. Run the command: ##sr discover zumnet true true## 62 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 63 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 57 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 64 64 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 65 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 59 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 60 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 66 66 67 67 = Zūm Wireless Discovery = 68 68