Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 14.1
edited by Alexander Mott
on 2022/10/10 23:35
on 2022/10/10 23:35
Change comment:
There is no comment for this version
To version 9.1
edited by Alexander Mott
on 2022/10/05 16:17
on 2022/10/05 16:17
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,6 +8,8 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 +(% class="row" %) 12 +((( 11 11 If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 12 12 13 13 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. ... ... @@ -19,7 +19,7 @@ 19 19 (% class="box errormessage" %) 20 20 ((( 21 21 * SHOWRUNNER™ version 3.014 or newer required 22 -* Zūm Wired firmware .pufversion 1.02.10 or greater required(ZUMNET-JBOX installed minimum version 1.001.00081)24 +* Zūm Wired firmware version 1.02.10 or greater required 23 23 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 24 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 25 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually ... ... @@ -48,21 +48,21 @@ 48 48 1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 49 49 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 50 50 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 51 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 52 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 53 53 1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 54 54 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 55 55 1. Run the command: ##sr discover zumnet true false## 56 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 56 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 57 +1*. One area will be created per ZUMNET-JBOX 57 57 1. Run the command: ##sr discover zumnet true true## 58 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 59 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 59 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 60 60 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 61 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 61 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 62 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 62 62 63 63 = Zūm Wireless Discovery = 64 64 65 65 == Notes and Limitations == 67 +))) 66 66 67 67 (% class="box errormessage" %) 68 68 ((( ... ... @@ -82,6 +82,8 @@ 82 82 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 83 83 ))) 84 84 87 +(% class="row" %) 88 +((( 85 85 == Manual RF Gateway Assignment Instructions == 86 86 87 87 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. ... ... @@ -303,3 +303,4 @@ 303 303 Removed Loads: 0 304 304 Zum Discovery Finished 305 305 }}} 310 +)))