Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 13.1
edited by Alexander Mott
on 2022/10/10 23:33
on 2022/10/10 23:33
Change comment:
There is no comment for this version
To version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
on 2022/09/23 00:00
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,6 +8,8 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 +(% class="row" %) 12 +((( 11 11 If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 12 12 13 13 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. ... ... @@ -16,14 +16,11 @@ 16 16 17 17 == Notes and Limitations == 18 18 19 -(% class="box errormessage" %) 20 -((( 21 21 * SHOWRUNNER™ version 3.014 or newer required 22 -* Zūm Wired firmware .pufversion 1.02.10 or greater required(ZUMNET-JBOX installed minimum version 1.001.00081)22 +* Zūm Wired firmware version 1.02.10 or greater required 23 23 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 24 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 25 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 26 -))) 27 27 28 28 == Steps == 29 29 ... ... @@ -48,25 +48,23 @@ 48 48 1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 49 49 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 50 50 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 51 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 52 -1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 53 53 1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 54 54 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 55 55 1. Run the command: ##sr discover zumnet true false## 56 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 53 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 54 +1*. One area will be created per ZUMNET-JBOX 57 57 1. Run the command: ##sr discover zumnet true true## 58 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 59 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 56 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 60 60 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 58 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 59 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 61 61 62 62 = Zūm Wireless Discovery = 63 63 64 64 == Notes and Limitations == 65 65 66 -(% class="box errormessage" %) 67 -((( 68 68 * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 69 -** For SHOWRUNNER™ versions prior to3.014 and newer, replace**##sr discover zummesh##**commands with**##sr discover zum##**66 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 70 70 * ZUM-NETBRIDGES must already be acquired to their respective gateway 71 71 * SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 72 72 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command ... ... @@ -81,19 +81,21 @@ 81 81 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 82 82 ))) 83 83 81 +(% class="row" %) 82 +((( 84 84 == Manual RF Gateway Assignment Instructions == 85 85 86 86 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 87 87 88 88 * Connect to the processor's console with Toolbox or your favorite SSH client. 89 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.90 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.91 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.92 -* Type ##sr discover zummeshfalse##and press enter.88 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 89 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 90 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 91 +* Type "//sr discover zum false//" and press enter. 93 93 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 94 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.95 -* Type ##progreset##and press enter to restart SHOWRUNNER™96 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.93 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 94 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 95 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 97 97 * Once completed SHOWRUNNER™ is now ready for full Zūm control 98 98 99 99 == Claim All RF Gateways Instructions == ... ... @@ -101,11 +101,11 @@ 101 101 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 102 102 103 103 * Connect to the processor's console with Toolbox or your favorite SSH client. 104 -* Type ##sr discover zummeshtrue##and press enter.103 +* Type "//sr discover zum true//" and press enter. 105 105 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 106 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.107 -* Type ##progreset##and press enter to restart SHOWRUNNER™108 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.105 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 106 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 107 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 109 109 * Once completed SHOWRUNNER™ is now ready for full Zūm control 110 110 111 111 == Examples == ... ... @@ -129,7 +129,7 @@ 129 129 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 130 130 Claimed ethernet device: CEN-GWEXER-9E6ADA 131 131 MC4>Update request from IP-ID-30 in Program 01 132 -MC4>sr discover zum meshfalse131 +MC4>sr discover zum false 133 133 Starting Zum Discovery without gateway claiming 134 134 MC4>Performing Discovery on 1 Gateways. 135 135 Evaluating 3 Devices on Gateway 30 ... ... @@ -162,7 +162,7 @@ 162 162 MC4>progreset 163 163 ... 164 164 CI ShowRunner startup completed successfully in 8072ms 165 -MC4>sr discover zum meshfalse164 +MC4>sr discover zum false 166 166 Starting Zum Discovery without gateway claiming 167 167 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 168 168 Performing Discovery on 1 Gateways. ... ... @@ -215,7 +215,7 @@ 215 215 216 216 === Claim All Example === 217 217 218 -{{{MC4>sr discover zum meshtrue217 +{{{MC4>sr discover zum true 219 219 Starting Zum Discovery with gateway claiming 220 220 MC4>Found 1 Gateways to check. 221 221 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -251,7 +251,7 @@ 251 251 MC4>progreset 252 252 ... 253 253 CI ShowRunner startup completed successfully in 8072ms 254 -MC4>sr discover zum meshfalse253 +MC4>sr discover zum false 255 255 Starting Zum Discovery without gateway claiming 256 256 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 257 257 Performing Discovery on 1 Gateways. ... ... @@ -302,3 +302,4 @@ 302 302 Removed Loads: 0 303 303 Zum Discovery Finished 304 304 }}} 304 +)))