Changes for page Zūm Discovery

Last modified by Alexander Mott on 2025/04/03 17:35

From version 13.1
edited by Alexander Mott
on 2022/10/10 23:33
Change comment: There is no comment for this version
To version 16.2
edited by Alexander Mott
on 2023/03/29 21:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,3 +1,8 @@
1 +(% class="box errormessage" %)
2 +(((
3 +WARNING: Cresnet Discovery is not currently working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before SHOWRUNNER™ can auto-discover hardware.
4 +)))
5 +
1 1  (% class="box warningmessage" %)
2 2  (((
3 3  This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
... ... @@ -16,7 +16,7 @@
16 16  
17 17  == Notes and Limitations ==
18 18  
19 -(% class="box errormessage" %)
24 +(% class="box warningmessage" %)
20 20  (((
21 21  * SHOWRUNNER™ version 3.014 or newer required
22 22  * Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081)
... ... @@ -58,12 +58,13 @@
58 58  1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration
59 59  1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area
60 60  1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware
66 +1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly.
61 61  
62 62  = Zūm Wireless Discovery =
63 63  
64 64  == Notes and Limitations ==
65 65  
66 -(% class="box errormessage" %)
72 +(% class="box warningmessage" %)
67 67  (((
68 68  * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
69 69  ** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##**
... ... @@ -73,7 +73,7 @@
73 73  * Plug loads will not appear in the SHOWRUNNER™ UI
74 74  )))
75 75  
76 -(% class="box warningmessage" id="HCaution:" %)
82 +(% class="box infomessage" id="HCaution:" %)
77 77  (((
78 78  **Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery
79 79