Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 12.1
edited by Alexander Mott
on 2022/10/06 14:25
on 2022/10/06 14:25
Change comment:
There is no comment for this version
To version 9.1
edited by Alexander Mott
on 2022/10/05 16:17
on 2022/10/05 16:17
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,6 +8,8 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 +(% class="row" %) 12 +((( 11 11 If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 12 12 13 13 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. ... ... @@ -51,10 +51,10 @@ 51 51 1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 52 52 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 53 53 1. Run the command: ##sr discover zumnet true false## 54 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 56 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 57 +1*. One area will be created per ZUMNET-JBOX 55 55 1. Run the command: ##sr discover zumnet true true## 56 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 57 -1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 59 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 58 58 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 59 59 1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 60 60 1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode ... ... @@ -62,6 +62,7 @@ 62 62 = Zūm Wireless Discovery = 63 63 64 64 == Notes and Limitations == 67 +))) 65 65 66 66 (% class="box errormessage" %) 67 67 ((( ... ... @@ -81,6 +81,8 @@ 81 81 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 82 82 ))) 83 83 87 +(% class="row" %) 88 +((( 84 84 == Manual RF Gateway Assignment Instructions == 85 85 86 86 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. ... ... @@ -302,3 +302,4 @@ 302 302 Removed Loads: 0 303 303 Zum Discovery Finished 304 304 }}} 310 +)))