Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 10.1
edited by Alexander Mott
on 2022/10/05 16:18
on 2022/10/05 16:18
Change comment:
There is no comment for this version
To version 7.1
edited by Alexander Mott
on 2022/09/22 23:59
on 2022/09/22 23:59
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,14 +18,11 @@ 18 18 19 19 == Notes and Limitations == 20 20 21 -(% class="box errormessage" %) 22 -((( 23 23 * SHOWRUNNER™ version 3.014 or newer required 24 24 * Zūm Wired firmware version 1.02.10 or greater required 25 25 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 26 26 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 27 27 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 28 -))) 29 29 30 30 == Steps == 31 31 ... ... @@ -39,7 +39,7 @@ 39 39 1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 40 40 1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 41 41 1*. Repeat the above steps for all ZUMNET-JBOXs 42 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox andproceed to the next step39 +1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, proceed to the next step 43 43 1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 44 44 1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 45 45 1*. If firmware was out-of-date, then this step should have already been completed ... ... @@ -51,8 +51,7 @@ 51 51 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 52 52 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 53 53 1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 54 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 55 -1. Run the command: ##sr discover zumnet true false## 51 +1. Connect to the processor in Toolbox and run the command: ##sr discover zumnet true false## 56 56 1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 57 57 1*. One area will be created per ZUMNET-JBOX 58 58 1. Run the command: ##sr discover zumnet true true## ... ... @@ -65,10 +65,8 @@ 65 65 66 66 == Notes and Limitations == 67 67 68 -(% class="box errormessage" %) 69 -((( 70 70 * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 71 -** For SHOWRUNNER™ versions prior to3.014 and newer, replace**##sr discover zummesh##**commands with**##sr discover zum##**65 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 72 72 * ZUM-NETBRIDGES must already be acquired to their respective gateway 73 73 * SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 74 74 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command ... ... @@ -83,19 +83,21 @@ 83 83 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 84 84 ))) 85 85 80 +(% class="row" %) 81 +((( 86 86 == Manual RF Gateway Assignment Instructions == 87 87 88 88 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 89 89 90 90 * Connect to the processor's console with Toolbox or your favorite SSH client. 91 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.92 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.93 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.94 -* Type ##sr discover zummeshfalse##and press enter.87 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 88 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 89 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 90 +* Type "//sr discover zum false//" and press enter. 95 95 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 96 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.97 -* Type ##progreset##and press enter to restart SHOWRUNNER™98 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.92 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 93 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 94 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 99 99 * Once completed SHOWRUNNER™ is now ready for full Zūm control 100 100 101 101 == Claim All RF Gateways Instructions == ... ... @@ -103,11 +103,11 @@ 103 103 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 104 104 105 105 * Connect to the processor's console with Toolbox or your favorite SSH client. 106 -* Type ##sr discover zummeshtrue##and press enter.102 +* Type "//sr discover zum true//" and press enter. 107 107 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 108 -* When the discovery is finished type ##sr save##and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.109 -* Type ##progreset##and press enter to restart SHOWRUNNER™110 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummeshfalse##and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.104 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 105 +* Type "//progreset//" and press enter to restart SHOWRUNNER™ 106 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 111 111 * Once completed SHOWRUNNER™ is now ready for full Zūm control 112 112 113 113 == Examples == ... ... @@ -131,7 +131,7 @@ 131 131 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 132 132 Claimed ethernet device: CEN-GWEXER-9E6ADA 133 133 MC4>Update request from IP-ID-30 in Program 01 134 -MC4>sr discover zum meshfalse130 +MC4>sr discover zum false 135 135 Starting Zum Discovery without gateway claiming 136 136 MC4>Performing Discovery on 1 Gateways. 137 137 Evaluating 3 Devices on Gateway 30 ... ... @@ -164,7 +164,7 @@ 164 164 MC4>progreset 165 165 ... 166 166 CI ShowRunner startup completed successfully in 8072ms 167 -MC4>sr discover zum meshfalse163 +MC4>sr discover zum false 168 168 Starting Zum Discovery without gateway claiming 169 169 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 170 170 Performing Discovery on 1 Gateways. ... ... @@ -217,7 +217,7 @@ 217 217 218 218 === Claim All Example === 219 219 220 -{{{MC4>sr discover zum meshtrue216 +{{{MC4>sr discover zum true 221 221 Starting Zum Discovery with gateway claiming 222 222 MC4>Found 1 Gateways to check. 223 223 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -253,7 +253,7 @@ 253 253 MC4>progreset 254 254 ... 255 255 CI ShowRunner startup completed successfully in 8072ms 256 -MC4>sr discover zum meshfalse252 +MC4>sr discover zum false 257 257 Starting Zum Discovery without gateway claiming 258 258 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 259 259 Performing Discovery on 1 Gateways.