Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 10.1
edited by Alexander Mott
on 2022/10/05 16:18
on 2022/10/05 16:18
Change comment:
There is no comment for this version
To version 13.1
edited by Alexander Mott
on 2022/10/10 23:33
on 2022/10/10 23:33
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,8 +8,6 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 -(% class="row" %) 12 -((( 13 13 If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 14 14 15 15 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. ... ... @@ -21,7 +21,7 @@ 21 21 (% class="box errormessage" %) 22 22 ((( 23 23 * SHOWRUNNER™ version 3.014 or newer required 24 -* Zūm Wired firmware version 1.02.10 or greater required 22 +* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 25 25 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 26 26 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 27 27 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually ... ... @@ -50,16 +50,16 @@ 50 50 1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 51 51 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 52 52 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 51 +1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 52 +1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 53 53 1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 54 54 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 55 55 1. Run the command: ##sr discover zumnet true false## 56 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 57 -1*. One area will be created per ZUMNET-JBOX 56 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 58 58 1. Run the command: ##sr discover zumnet true true## 59 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 58 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 59 +1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 60 60 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 61 -1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 62 -1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 63 63 64 64 = Zūm Wireless Discovery = 65 65 ... ... @@ -304,4 +304,3 @@ 304 304 Removed Loads: 0 305 305 Zum Discovery Finished 306 306 }}} 307 -)))