Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 1.2
edited by Alexander Mott
on 2022/09/22 21:31
on 2022/09/22 21:31
Change comment:
There is no comment for this version
To version 38.2
edited by Alexander Mott
on 2025/04/03 16:11
on 2025/04/03 16:11
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Autodiscovery1 +Zūm Discovery - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. DeviceAddressing.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.WebHome - Content
-
... ... @@ -1,6 +1,14 @@ 1 +(% class="box errormessage" %) 2 +((( 3 +ūūūūūū**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 + 5 +**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 +ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 +))) 8 + 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -This article is about automatically building a S HOWRUNNER™ configuration using the ZūmAutodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.WiringGuide.Zūm Wired System Overview.Crestron11 +This article is about automatically building a ShowRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]]. 4 4 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 5 5 ))) 6 6 ... ... @@ -8,31 +8,366 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 -(% class="row" %) 12 -((( 13 -Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum. 19 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 14 14 15 - =Para1=21 +There are certain pre-requisites and limitations when building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 16 16 17 -Lore m23 += Discovery Filter (ShowRunnerCLC™ 3.062 or newer) = 18 18 19 - ==Sub1==25 +Discovered ethernet devices may be filtered using either a hostname or IP Address filter. The filter is configured from the command line interface. 20 20 21 -Lorem 27 +##+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+ 28 +~| Command | Help | 29 +~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-| 30 +~| SR discover clear filter | Remove Discovery Filter | 31 +~| SR discover filter | Show Discovery Filter | 32 +~| SR discover filter (X:S) | Set Discovery Filter | 33 +~| - | (X):S:Filter String | 34 +~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|## 22 22 23 -== Sub2==36 +=== Hostname Filter === 24 24 25 - Lorem38 +The Hostname filter uses a regular expression to filter discovered ZUMNET GATEWAYs or JBOXs. Multiple expressions can be applied by using a comma to separate the expressions. 26 26 27 - =Para2=40 +Command Syntax: ##"Type='Hostname' Settings='Expr1[,Expr2]'"## 28 28 29 - Lorem42 +Examples: 30 30 31 -== Sub 1 == 44 +1. Only include hostnames that start with ZUMNET-06: 45 +(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-06'" 46 +1. Include hostnames that start with ZUMNET-FL01 or contain FL03: 47 +(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-FL01,FL03'" 32 32 33 - Lorem49 +=== IP Address Filter === 34 34 35 - ==Sub2==51 +The IP Address filter will restrict discovered ZUMNET GATEWAYs or JBOXs to matching IP Addresses or IP Address ranges. Multiple addresses and ranges can be used. 36 36 37 -Lorem 53 +Command Syntax: ##"Type='IPAddress' Settings='Address[,AddressStart-AddressEnd]'"## 54 + 55 +Examples: 56 + 57 +1. Only include a device with an address of 192.168.0.10 or 192.168.0.50: 58 +(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.10,192.168.0.50'" 59 +1. Include addresses between 192.168.0.11 and 192.168.0.50 and 192.168.0.200 and 192.168.0.240: 60 +(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.11-192.168.0.50,192.168.0.200-192.168.0.240'" 61 + 62 +=== IP-ID Filter (Added in SR v3.067) === 63 + 64 +The IP-ID filter will restrict discovered ZUMNET GATEWAYs or JBOXs to matching IP-IDs or IP-ID ranges. Multiple IDs and ranges can be used. 65 + 66 +Command Syntax: ##"Type='IPID' Settings='IPID[,IPIDStart-IPIDEnd]'"## 67 + 68 +Examples: 69 + 70 +1. Only include a device with an IP-ID of 10 or 5A: 71 +(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPID' Settings='10,5A'" 72 +1. Include addresses between 11 and 4F and A0 and BF: 73 +(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPID' Settings='11-4F,A0-BF'" 74 + 75 += Zūm Wired Discovery = 76 + 77 +== Notes and Limitations == 78 + 79 +(% class="box warningmessage" %) 80 +((( 81 +* ShowRunnerCLC™ version 3.014 or newer required 82 +* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 83 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox and confirm all hardware (NETs and LINKs) are online prior to running the discovery commands 84 +* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 85 +* ZUMLINK-IOs will not be discovered (Expected to be discoverable in future ShowRunnerCLC™ release) 86 +* ZUMLINK-KPs will not be discovered on older versions of ShowRunnerCLC™ (v3.058 or newer will discover keypads and set as remote type) 87 +* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 38 38 ))) 89 + 90 +== Steps == 91 + 92 +1. [[Install ShowRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 93 +1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 94 +1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 95 +1*. Connect to the first ZUMNET-JBOX in Toolbox 96 +1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 97 +1**. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 98 +1**. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 99 +1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 100 +1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 101 +1*. Repeat the above steps for all ZUMNET-JBOXs 102 +1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 103 +1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 104 +1*. Commission room through the app 105 +1**. configure keypad logic 106 +1**. configure occupancy sensor settings 107 +1**. calibrate photocell(s) 108 +1*. Set hostnames for the ZUMNETs. 109 +1**. Zūm discovery will bring in hostnames. 110 +1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 111 +1*. If firmware was out-of-date, then this step should have already been completed 112 +1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 113 +1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 114 +1*. If firmware was out-of-date, then this step should have already been completed 115 +1*. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 116 +1*. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 117 +1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 118 +1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 119 +1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 120 +1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 121 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 122 +1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 123 +1. If trying to Auto Discover on a job with multiple processors or you are returning to a job where new ZUMNET-JBOXs have been added and you only wish to Auto Discover those new devices, ShowRunnerCLC™ 3.062 and newer allow [[filtering based on hostname or IP address>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Zūm Discovery.WebHome||anchor="HDiscoveryFilter28ShowRunnerCLC21223.062ornewer29"]] in order to limit the devices that are brought into the ShowRunnerCLC™ configuration 124 +1. Run the command: ##sr discover zumnet true true## to add ZUMNET-JBOXs, connected ZUMLINK devices, and some Cresnet devices (such as Cameo keypads) to the configuration. (Note 125 +1*. This command will update the ShowRunnerCLC™ configuration with: 126 +1**. One area per claimed ZUMNET-JBOX based on the Room Name set in the app 127 +1**. One ZUMNET-BRIDGE load controller per claimed ZUMNET-JBOX to allow the Zūm Room to communicate its current status (scene, occupancy, etc.) to ShowRunnerCLC™ 128 +1**. One entry for each ZUMLINK-KP, ZUMLINK-JBOX, and ZUMLINK occupancy sensor connected to each ZUMNET-JBOX 129 +1***. All devices and loads will be auto-labeled based on their connection information, //not// the names they are given in the Zūm App 130 +1***. Keypads will be brought in as "Remote" type and only follow the logic as defined in the Zūm App, allowing for scheduled enabling/disabling of keypads without adding any additional button functions from ShowRunnerCLC™ 131 +1***. Occupancy sensors will be brought in with "Use Hardware Logic" and only follow the logic as defined in the Zūm App 132 +1*. Optionally, run ##sr discover zumnet false true## to only add new ZUMLINK devices to the configuration. **Note that previously added ZUMLINK devices will be added again if their CID has been changed** 133 +1*. Run ##sr discover zumnet true false## to add ZUMNET-JBOXs without bringing in any devices. **Note that if a ZUMNET-JBOX already has an entry in its IP Table, ShowRunnerCLC™ will not claim it.** The ZUMNET-JBOX's IP Table must be cleared in order for it to be claimed by the ShowRunnerCLC™ program 134 +1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 135 +1. If new Zūm Link hardware has been added, it is not necessary to do a full Auto Discovery to bring the new devices into ShowRunnerCLC™; instead you can just run ##sr discover zumnet false true## to bring in the new Zūm Link devices without claiming any new Zūm Net devices 136 + 137 += Zūm Wireless Discovery = 138 + 139 +== Notes and Limitations == 140 + 141 +(% class="box warningmessage" %) 142 +((( 143 +* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 144 +** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 145 +* ZUM-NETBRIDGES must already be acquired to their respective gateway 146 +* ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 147 +* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 148 +* Plug loads will not appear in the ShowRunnerCLC™ UI 149 +* Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER 150 +))) 151 + 152 +(% class="box infomessage" id="HCaution:" %) 153 +((( 154 +**Note:** ShowRunnerCLC™ has two different approaches for Zūm Wireless Discovery 155 + 156 +1. **Manual RF Gateway Assignment** - ShowRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 157 +1. **Claim All RF Gateways** - ShowRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network. 158 +))) 159 + 160 +== Manual RF Gateway Assignment Instructions == 161 + 162 +Use this method if you have multiple ShowRunnerCLC™ instances on the same network or have gateways used by other Crestron systems. 163 + 164 +* Connect to the processor's console with Toolbox or your favorite SSH client. 165 +* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways. 166 +* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices. 167 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step. 168 +* Type ##sr discover zummesh false## and press enter. 169 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 170 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process. 171 +* Type ##progreset## and press enter to restart ShowRunnerCLC™ 172 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point. 173 +* Once completed SHOWRUNNER™ is now ready for full Zūm control 174 + 175 +== Claim All RF Gateways Instructions == 176 + 177 +Use this method when you have a single ShowRunnerCLC™ instance on a local network with all gateways being used for ShowRunnerCLC™. 178 + 179 +* Connect to the processor's console with Toolbox or your favorite SSH client. 180 +* Type ##sr discover zummesh true## and press enter. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step. 181 +* Type ##sr discover zummesh false## and press enter. 182 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 183 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process. 184 +* Type ##progreset## and press enter to restart ShowRunnerCLC™ 185 +* Once ShowRunnerCLC™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point. 186 +* Once completed ShowRunnerCLC™ is now ready for full Zūm control 187 + 188 +== Examples == 189 + 190 +=== Manual Example === 191 + 192 +{{{MC4>sr devmgr ethernet query 193 +Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 194 +MC4>sr devmgr ethernet show devices 195 + 196 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 197 +| Adapter | Hostname | IP Address | IP-ID | ID | 198 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 199 +| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 | 200 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 201 +| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] | 202 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 203 +| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] | 204 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 205 + 206 +MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 207 +Claimed ethernet device: CEN-GWEXER-9E6ADA 208 +MC4>Update request from IP-ID-30 in Program 01 209 +MC4>sr discover zummesh false 210 +Starting Zum Discovery without gateway claiming 211 +MC4>Performing Discovery on 1 Gateways. 212 +Evaluating 3 Devices on Gateway 30 213 +Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 214 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 215 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 03 216 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 217 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 04 218 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 04 219 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 220 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 221 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 222 +Querying cresnet 223 +Discovering Zum Loads on 1 Gateways. 224 +Discovering Zum Loads on 3 Devices. 225 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 226 +Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 227 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 228 +Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 229 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 230 +Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 231 +RF Gateways: 0 232 +RF Devices: 3 233 +New Loads: 0 234 +Modified Loads: 0 235 +Removed Loads: 0 236 +Zum Discovery Finished 237 +MC4>sr save 238 +Saved config 239 +MC4>progreset 240 +... 241 +CI ShowRunner startup completed successfully in 8072ms 242 +MC4>sr discover zummesh false 243 +Starting Zum Discovery without gateway claiming 244 +MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 245 +Performing Discovery on 1 Gateways. 246 +Evaluating 3 Devices on Gateway 30 247 +Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 248 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 03 249 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 250 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 04 251 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 252 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 05 253 +Discovering Zum Loads on 1 Gateways. 254 +Discovering Zum Loads on 3 Devices. 255 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 256 +Evaluating Device: ZUM-JBOX-20A-PLUG ShortAddress: 0000 Type: PlugLoad 257 +Evaluating Device: ZUM-KP10C-BATT ShortAddress: 52E5 Type: Keypad 258 +Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: DAF1 Type: OccupancySensor 259 +Evaluating Device: ZUM-JBOX-5A-LV ShortAddress: 92EF Type: DimmableLoad 260 +Load: Load37615 Added 261 +NETBIRDGE: NewLoads: 1 ModifiedLoads: 0 RemovedLoads: 0 262 +Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 263 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 264 +Evaluating Device: ZUM-DALI ShortAddress: 740D Type: Unknown 265 +Evaluating Device: ZUM-5A-LV ShortAddress: 0482 Type: DimmableLoad 266 +Load: Load1154 Added 267 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 0000 Type: DimmableLoad 268 +Load: Load0 Added 269 +Evaluating Device: ZUM-KP10C-BATT ShortAddress: D766 Type: Keypad 270 +Evaluating Device: ZUM-OL-PHO-BATT ShortAddress: 95ED Type: Photocell 271 +Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: 44C2 Type: OccupancySensor 272 +Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 273 +Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 274 +NETBIRDGE: NewLoads: 2 ModifiedLoads: 0 RemovedLoads: 0 275 +Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 276 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 277 +Evaluating Device: ZUM-SIM ShortAddress: 0000 Type: OccupancySensor, PartitionSensor 278 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: EBCF Type: DimmableLoad 279 +Load: Load60367 Added 280 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 3CC1 Type: DimmableLoad 281 +Load: Load15553 Added 282 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: F94A Type: DimmableLoad 283 +Load: Load63818 Added 284 +NETBIRDGE: NewLoads: 3 ModifiedLoads: 0 RemovedLoads: 0 285 +Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 286 +RF Gateways: 0 287 +RF Devices: 3 288 +New Loads: 6 289 +Modified Loads: 0 290 +Removed Loads: 0 291 +Zum Discovery Finished}}} 292 + 293 +=== Claim All Example === 294 + 295 +{{{MC4>sr discover zummesh true 296 +Starting Zum Discovery with gateway claiming 297 +MC4>Found 1 Gateways to check. 298 +Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 299 +Update request from IP-ID-30 in Program 01 300 +Claimed 1 Gateways. Waiting for queries to finish. 301 +Performing Discovery on 1 Gateways. 302 +Evaluating 3 Devices on Gateway 30 303 +Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 304 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 305 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 03 306 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 307 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 04 308 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 04 309 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 310 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 311 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 312 +Discovering Zum Loads on 1 Gateways. 313 +Discovering Zum Loads on 3 Devices. 314 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 315 +Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 316 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 317 +Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 318 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 319 +Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 320 +RF Gateways: 0 321 +RF Devices: 3 322 +New Loads: 0 323 +Modified Loads: 0 324 +Removed Loads: 0 325 +Zum Discovery Finished 326 +MC4>sr save 327 +Saved config 328 +MC4>progreset 329 +... 330 +CI ShowRunner startup completed successfully in 8072ms 331 +MC4>sr discover zummesh false 332 +Starting Zum Discovery without gateway claiming 333 +MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 334 +Performing Discovery on 1 Gateways. 335 +Evaluating 3 Devices on Gateway 30 336 +Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 337 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 03 338 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 339 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 04 340 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 341 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 05 342 +Discovering Zum Loads on 1 Gateways. 343 +Discovering Zum Loads on 3 Devices. 344 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 345 +Evaluating Device: ZUM-JBOX-20A-PLUG ShortAddress: 0000 Type: PlugLoad 346 +Evaluating Device: ZUM-KP10C-BATT ShortAddress: 52E5 Type: Keypad 347 +Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: DAF1 Type: OccupancySensor 348 +Evaluating Device: ZUM-JBOX-5A-LV ShortAddress: 92EF Type: DimmableLoad 349 +Load: Load37615 Added 350 +NETBIRDGE: NewLoads: 1 ModifiedLoads: 0 RemovedLoads: 0 351 +Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 352 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 353 +Evaluating Device: ZUM-DALI ShortAddress: 740D Type: Unknown 354 +Evaluating Device: ZUM-5A-LV ShortAddress: 0482 Type: DimmableLoad 355 +Load: Load1154 Added 356 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 0000 Type: DimmableLoad 357 +Load: Load0 Added 358 +Evaluating Device: ZUM-KP10C-BATT ShortAddress: D766 Type: Keypad 359 +Evaluating Device: ZUM-OL-PHO-BATT ShortAddress: 95ED Type: Photocell 360 +Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: 44C2 Type: OccupancySensor 361 +Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 362 +Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 363 +NETBIRDGE: NewLoads: 2 ModifiedLoads: 0 RemovedLoads: 0 364 +Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 365 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 366 +Evaluating Device: ZUM-SIM ShortAddress: 0000 Type: OccupancySensor, PartitionSensor 367 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: EBCF Type: DimmableLoad 368 +Load: Load60367 Added 369 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 3CC1 Type: DimmableLoad 370 +Load: Load15553 Added 371 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: F94A Type: DimmableLoad 372 +Load: Load63818 Added 373 +NETBIRDGE: NewLoads: 3 ModifiedLoads: 0 RemovedLoads: 0 374 +Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 375 +RF Gateways: 0 376 +RF Devices: 3 377 +New Loads: 6 378 +Modified Loads: 0 379 +Removed Loads: 0 380 +Zum Discovery Finished 381 +}}}