Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 1.1
edited by Alexander Mott
on 2022/09/22 21:31
on 2022/09/22 21:31
Change comment:
There is no comment for this version
To version 10.1
edited by Alexander Mott
on 2022/10/05 16:18
on 2022/10/05 16:18
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Autodiscovery1 +Zūm Discovery - Content
-
... ... @@ -1,6 +1,6 @@ 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 4 4 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 5 5 ))) 6 6 ... ... @@ -10,29 +10,298 @@ 10 10 11 11 (% class="row" %) 12 12 ((( 13 - Loremipsumdolor sit amet,consecteturadipiscingelit, seddoeiusmodtemporincididuntut laboreetdolore magnaaliqua.Utimad minimveniam, quisnostrudexercitation ullamcolaboris nisiut aliquipex eacommodoconsequat. Duis aute irure dolor inreprehenderitinvoluptatevelitessecillum doloreeufugiatnulla pariatur. Excepteursintoccaecatcupidatat non proident,suntin culpa quiofficia deserunt mollitanim id estlaborum.13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 14 14 15 - =Para1=15 +There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 16 16 17 - Lorem17 += Zūm Wired Discovery = 18 18 19 -== Sub1==19 +== Notes and Limitations == 20 20 21 -Lorem 21 +(% class="box errormessage" %) 22 +((( 23 +* SHOWRUNNER™ version 3.014 or newer required 24 +* Zūm Wired firmware version 1.02.10 or greater required 25 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 26 +* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 27 +* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 28 +))) 22 22 23 -== S ub2==30 +== Steps == 24 24 25 -Lorem 32 +1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 33 +1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 34 +1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 35 +1*. Connect to the first ZUMNET-JBOX in Toolbox 36 +1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 37 +1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 38 +1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 39 +1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 40 +1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 41 +1*. Repeat the above steps for all ZUMNET-JBOXs 42 +1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 43 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 44 +1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 45 +1*. If firmware was out-of-date, then this step should have already been completed 46 +1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 47 +1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 48 +1*. If firmware was out-of-date, then this step should have already been completed 49 +1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 50 +1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 51 +1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 52 +1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 53 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 54 +1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 55 +1. Run the command: ##sr discover zumnet true false## 56 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 57 +1*. One area will be created per ZUMNET-JBOX 58 +1. Run the command: ##sr discover zumnet true true## 59 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 60 +1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 61 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 62 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 26 26 27 -= Para2=64 += Zūm Wireless Discovery = 28 28 29 - Lorem66 +== Notes and Limitations == 30 30 31 -== Sub 1 == 68 +(% class="box errormessage" %) 69 +((( 70 +* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 71 +** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 72 +* ZUM-NETBRIDGES must already be acquired to their respective gateway 73 +* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 74 +* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 75 +* Plug loads will not appear in the SHOWRUNNER™ UI 76 +))) 32 32 33 -Lorem 78 +(% class="box warningmessage" id="HCaution:" %) 79 +((( 80 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery 34 34 35 -== Sub 2 == 82 +1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 83 +1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 84 +))) 36 36 37 -Lorem 86 +== Manual RF Gateway Assignment Instructions == 87 + 88 +Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 89 + 90 +* Connect to the processor's console with Toolbox or your favorite SSH client. 91 +* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways. 92 +* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices. 93 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 94 +* Type ##sr discover zummesh false## and press enter. 95 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 96 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 97 +* Type ##progreset## and press enter to restart SHOWRUNNER™ 98 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 99 +* Once completed SHOWRUNNER™ is now ready for full Zūm control 100 + 101 +== Claim All RF Gateways Instructions == 102 + 103 +Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 104 + 105 +* Connect to the processor's console with Toolbox or your favorite SSH client. 106 +* Type ##sr discover zummesh true## and press enter. 107 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 108 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 109 +* Type ##progreset## and press enter to restart SHOWRUNNER™ 110 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 111 +* Once completed SHOWRUNNER™ is now ready for full Zūm control 112 + 113 +== Examples == 114 + 115 +=== Manual Example === 116 + 117 +{{{MC4>sr devmgr ethernet query 118 +Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 119 +MC4>sr devmgr ethernet show devices 120 + 121 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 122 +| Adapter | Hostname | IP Address | IP-ID | ID | 123 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 124 +| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 | 125 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 126 +| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] | 127 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 128 +| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] | 129 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 130 + 131 +MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 132 +Claimed ethernet device: CEN-GWEXER-9E6ADA 133 +MC4>Update request from IP-ID-30 in Program 01 134 +MC4>sr discover zummesh false 135 +Starting Zum Discovery without gateway claiming 136 +MC4>Performing Discovery on 1 Gateways. 137 +Evaluating 3 Devices on Gateway 30 138 +Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 139 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 140 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 03 141 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 142 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 04 143 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 04 144 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 145 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 146 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 147 +Querying cresnet 148 +Discovering Zum Loads on 1 Gateways. 149 +Discovering Zum Loads on 3 Devices. 150 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 151 +Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 152 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 153 +Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 154 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 155 +Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 156 +RF Gateways: 0 157 +RF Devices: 3 158 +New Loads: 0 159 +Modified Loads: 0 160 +Removed Loads: 0 161 +Zum Discovery Finished 162 +MC4>sr save 163 +Saved config 164 +MC4>progreset 165 +... 166 +CI ShowRunner startup completed successfully in 8072ms 167 +MC4>sr discover zummesh false 168 +Starting Zum Discovery without gateway claiming 169 +MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 170 +Performing Discovery on 1 Gateways. 171 +Evaluating 3 Devices on Gateway 30 172 +Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 173 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 03 174 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 175 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 04 176 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 177 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 05 178 +Discovering Zum Loads on 1 Gateways. 179 +Discovering Zum Loads on 3 Devices. 180 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 181 +Evaluating Device: ZUM-JBOX-20A-PLUG ShortAddress: 0000 Type: PlugLoad 182 +Evaluating Device: ZUM-KP10C-BATT ShortAddress: 52E5 Type: Keypad 183 +Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: DAF1 Type: OccupancySensor 184 +Evaluating Device: ZUM-JBOX-5A-LV ShortAddress: 92EF Type: DimmableLoad 185 +Load: Load37615 Added 186 +NETBIRDGE: NewLoads: 1 ModifiedLoads: 0 RemovedLoads: 0 187 +Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 188 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 189 +Evaluating Device: ZUM-DALI ShortAddress: 740D Type: Unknown 190 +Evaluating Device: ZUM-5A-LV ShortAddress: 0482 Type: DimmableLoad 191 +Load: Load1154 Added 192 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 0000 Type: DimmableLoad 193 +Load: Load0 Added 194 +Evaluating Device: ZUM-KP10C-BATT ShortAddress: D766 Type: Keypad 195 +Evaluating Device: ZUM-OL-PHO-BATT ShortAddress: 95ED Type: Photocell 196 +Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: 44C2 Type: OccupancySensor 197 +Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 198 +Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 199 +NETBIRDGE: NewLoads: 2 ModifiedLoads: 0 RemovedLoads: 0 200 +Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 201 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 202 +Evaluating Device: ZUM-SIM ShortAddress: 0000 Type: OccupancySensor, PartitionSensor 203 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: EBCF Type: DimmableLoad 204 +Load: Load60367 Added 205 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 3CC1 Type: DimmableLoad 206 +Load: Load15553 Added 207 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: F94A Type: DimmableLoad 208 +Load: Load63818 Added 209 +NETBIRDGE: NewLoads: 3 ModifiedLoads: 0 RemovedLoads: 0 210 +Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 211 +RF Gateways: 0 212 +RF Devices: 3 213 +New Loads: 6 214 +Modified Loads: 0 215 +Removed Loads: 0 216 +Zum Discovery Finished}}} 217 + 218 +=== Claim All Example === 219 + 220 +{{{MC4>sr discover zummesh true 221 +Starting Zum Discovery with gateway claiming 222 +MC4>Found 1 Gateways to check. 223 +Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 224 +Update request from IP-ID-30 in Program 01 225 +Claimed 1 Gateways. Waiting for queries to finish. 226 +Performing Discovery on 1 Gateways. 227 +Evaluating 3 Devices on Gateway 30 228 +Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 229 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 230 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 03 231 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 232 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 04 233 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 04 234 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 235 +Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 236 +Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 237 +Discovering Zum Loads on 1 Gateways. 238 +Discovering Zum Loads on 3 Devices. 239 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 240 +Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 241 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 242 +Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 243 +NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 244 +Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 245 +RF Gateways: 0 246 +RF Devices: 3 247 +New Loads: 0 248 +Modified Loads: 0 249 +Removed Loads: 0 250 +Zum Discovery Finished 251 +MC4>sr save 252 +Saved config 253 +MC4>progreset 254 +... 255 +CI ShowRunner startup completed successfully in 8072ms 256 +MC4>sr discover zummesh false 257 +Starting Zum Discovery without gateway claiming 258 +MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 259 +Performing Discovery on 1 Gateways. 260 +Evaluating 3 Devices on Gateway 30 261 +Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 262 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 03 263 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03096 from IP-ID: 30 264 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 04 265 +Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 266 +Dev: ZUMMESH-NETBRIDGE already claimed at RF ID: 05 267 +Discovering Zum Loads on 1 Gateways. 268 +Discovering Zum Loads on 3 Devices. 269 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 270 +Evaluating Device: ZUM-JBOX-20A-PLUG ShortAddress: 0000 Type: PlugLoad 271 +Evaluating Device: ZUM-KP10C-BATT ShortAddress: 52E5 Type: Keypad 272 +Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: DAF1 Type: OccupancySensor 273 +Evaluating Device: ZUM-JBOX-5A-LV ShortAddress: 92EF Type: DimmableLoad 274 +Load: Load37615 Added 275 +NETBIRDGE: NewLoads: 1 ModifiedLoads: 0 RemovedLoads: 0 276 +Device: ZUM Netbridge 30:03 at 30:03 discovery result: . 277 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 278 +Evaluating Device: ZUM-DALI ShortAddress: 740D Type: Unknown 279 +Evaluating Device: ZUM-5A-LV ShortAddress: 0482 Type: DimmableLoad 280 +Load: Load1154 Added 281 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 0000 Type: DimmableLoad 282 +Load: Load0 Added 283 +Evaluating Device: ZUM-KP10C-BATT ShortAddress: D766 Type: Keypad 284 +Evaluating Device: ZUM-OL-PHO-BATT ShortAddress: 95ED Type: Photocell 285 +Evaluating Device: ZUM-PIR-OCC-BATT ShortAddress: 44C2 Type: OccupancySensor 286 +Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 287 +Evaluating Device: ZUM-DALI-GROUP ShortAddress: 740D Type: Unknown 288 +NETBIRDGE: NewLoads: 2 ModifiedLoads: 0 RemovedLoads: 0 289 +Device: ZUM Netbridge 30:04 at 30:04 discovery result: . 290 +Evaluating Device: ZUM-BLE ShortAddress: FFFA Type: BLERadio 291 +Evaluating Device: ZUM-SIM ShortAddress: 0000 Type: OccupancySensor, PartitionSensor 292 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: EBCF Type: DimmableLoad 293 +Load: Load60367 Added 294 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: 3CC1 Type: DimmableLoad 295 +Load: Load15553 Added 296 +Evaluating Device: ZUM-JBOX-16A-LV ShortAddress: F94A Type: DimmableLoad 297 +Load: Load63818 Added 298 +NETBIRDGE: NewLoads: 3 ModifiedLoads: 0 RemovedLoads: 0 299 +Device: ZUM Netbridge 30:05 at 30:05 discovery result: . 300 +RF Gateways: 0 301 +RF Devices: 3 302 +New Loads: 6 303 +Modified Loads: 0 304 +Removed Loads: 0 305 +Zum Discovery Finished 306 +}}} 38 38 )))