Changes for page Pre-Construction Checklist
Last modified by Alexander Mott on 2024/01/05 19:12
From version 9.1
edited by Alexander Mott
on 2023/04/21 19:12
on 2023/04/21 19:12
Change comment:
There is no comment for this version
To version 7.1
edited by Scott Kohlmann
on 2023/04/20 22:38
on 2023/04/20 22:38
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. alexander\.mott@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -9,22 +9,19 @@ 9 9 * [[Wiring and Installation>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.WebHome]] 10 10 ** Do not power up panels until installation is complete and wiring is verified safe to connect 11 11 ** [[Cresnet wiring>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Cresnet.WebHome]] (for jobs with Cresnet) 12 -*** (% style="color:green" %)**DO**(%%)check for shorts before landing at the panel13 -*** (% style="color:green" %)**DO**(%%)land the shield with COM at the panel14 -*** (% style="color:green" %)**DO**(%%)splice through and insulate shield in the field15 -*** (% style="color:green" %)**DO**(%%)use wire nuts for Cresnet splices16 -*** (% style="color:red" %)**DONOT**(%%)17 -*** (% style="color:red" %)**DONOT**(%%)leave copper showing at terminations18 -*** (% style="color:red" %)**DONOT**(%%)excessively strip back the teal-yellow jacket12 +*** **Do** check for shorts before landing at the panel 13 +*** **Do** land the shield with COM at the panel 14 +*** **Do** splice through and insulate shield in the field 15 +*** **Do** use wire nuts for Cresnet splices 16 +*** **Do not** use lever-nuts for Cresnet splices 17 +*** **Do not** leave copper showing at terminations 18 +*** **Do not** excessively strip back the teal-yellow jacket 19 19 ** [[Ethernet terminations>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome]] (where the EC is terminating the Ethernet) 20 -*** (% style="color:green" %)**DO**(%%) use T568B Pin-Out 21 -*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 terminations 22 -*** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length 20 +*** **Do** use T568B Pin-Out 21 +*** **Do not** exceed 100m/328' cable length 23 23 ** [[Zūm Wired wiring>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome]] (for Zūm Wired jobs) 24 -*** (% style="color:green" %)**DO**(%%) use T568B Pin-Out 25 -*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 terminations 26 -*** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length 27 -*** (% style="color:red" %)**DO NOT**(%%) mix up Zūm Net and Zūm Link cables 23 +*** **Do** follow the same rules as Ethernet for both Zūm Net and Zūm Link terminations/cable length 24 +*** **Do not** mix up Zūm Net and Zūm Link cables 28 28 ** Follow the load schedule 29 29 * Serial number collection 30 30 ** SNs should be collected for all networked devices (all Cresnet devices and Zūm Wired devices)