9 9  * [[Wiring and Installation>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.WebHome]]
10 10  ** Do not power up panels until installation is complete and wiring is verified safe to connect
11 11  ** [[Cresnet wiring>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Cresnet.WebHome]] (for jobs with Cresnet)
12 -*** **Do** check for shorts before landing at the panel
13 -*** **Do** land the shield with COM at the panel
14 -*** **Do** splice through and insulate shield in the field
15 -*** **Do** use wire nuts for Cresnet splices
16 -*** **Do not** use lever-nuts for Cresnet splices
17 -*** **Do not** leave copper showing at terminations
18 -*** **Do not** excessively strip back the teal-yellow jacket
12 +*** (% style="color:green" %)**DO**(%%) check for shorts before landing at the panel
13 +*** (% style="color:green" %)**DO**(%%) land the shield with COM at the panel
14 +*** (% style="color:green" %)**DO**(%%) splice through and insulate shield in the field
15 +*** (% style="color:green" %)**DO**(%%) use wire nuts for Cresnet splices
16 +*** (% style="color:red" %)**DO NOT**(%%) use lever-nuts for Cresnet splices
17 +*** (% style="color:red" %)**DO NOT**(%%) leave copper showing at terminations
18 +*** (% style="color:red" %)**DO NOT**(%%) excessively strip back the teal-yellow jacket
19 19  ** [[Ethernet terminations>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome]] (where the EC is terminating the Ethernet)
20 -*** **Do** use T568B Pin-Out
21 -*** **Do not** use EZ-style passthrough RJ-45 terminations
22 -*** **Do not** exceed 100m/328' cable length
20 +*** (% style="color:green" %)**DO**(%%) use T568B Pin-Out
21 +*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 terminations
22 +*** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length
23 23  ** [[Zūm Wired wiring>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome]] (for Zūm Wired jobs)
24 -*** **Do** use T568B Pin-Out
25 -*** **Do not** use EZ-style passthrough RJ-45 terminations
26 -*** **Do not** exceed 100m/328' cable length
27 -*** **Do not** mix up Zūm Net and Zūm Link cables
24 +*** (% style="color:green" %)**DO**(%%) use T568B Pin-Out
25 +*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 terminations
26 +*** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length
27 +*** (% style="color:red" %)**DO NOT**(%%) mix up Zūm Net and Zūm Link cables
28 28  ** Follow the load schedule
29 29  * Serial number collection
30 30  ** SNs should be collected for all networked devices (all Cresnet devices and Zūm Wired devices)