Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,22 +9,22 @@ 9 9 * [[Wiring and Installation>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.WebHome]] 10 10 ** Do not power up panels until installation is complete and wiring is verified safe to connect 11 11 ** [[Cresnet wiring>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Cresnet.WebHome]] (for jobs with Cresnet) 12 -*** **D o**13 -*** **D o** land the shield with COM at the panel14 -*** **D o** splice through and insulate shield in the field15 -*** **D o** use wire nuts for Cresnet splices16 -*** **D onot** use lever-nuts for Cresnet splices17 -*** **D onot** leave copper showing at terminations18 -*** **D onot** excessively strip back the teal-yellow jacket12 +*** (% style="color:green" %)**DO**(%%) check for shorts before landing at the panel 13 +*** (% style="color:green" %)**DO**(%%) land the shield with COM at the panel 14 +*** (% style="color:green" %)**DO**(%%) splice through and insulate shield in the field 15 +*** (% style="color:green" %)**DO**(%%) use wire nuts for Cresnet splices 16 +*** (% style="color:red" %)**DO NOT**(%%) use lever-nuts for Cresnet splices 17 +*** (% style="color:red" %)**DO NOT**(%%) leave copper showing at terminations 18 +*** (% style="color:red" %)**DO NOT**(%%) excessively strip back the teal-yellow jacket 19 19 ** [[Ethernet terminations>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome]] (where the EC is terminating the Ethernet) 20 -*** **D o** use T568B Pin-Out21 -*** **D onot** use EZ-style passthrough RJ-45 terminations22 -*** **D onot** exceed 100m/328' cable length20 +*** (% style="color:green" %)**DO**(%%) use T568B Pin-Out 21 +*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 terminations 22 +*** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length 23 23 ** [[Zūm Wired wiring>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome]] (for Zūm Wired jobs) 24 -*** **D o** use T568B Pin-Out25 -*** **D onot** use EZ-style passthrough RJ-45 terminations26 -*** **D onot** exceed 100m/328' cable length27 -*** **D onot** mix up Zūm Net and Zūm Link cables24 +*** (% style="color:green" %)**DO**(%%) use T568B Pin-Out 25 +*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 terminations 26 +*** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length 27 +*** (% style="color:red" %)**DO NOT**(%%) mix up Zūm Net and Zūm Link cables 28 28 ** Follow the load schedule 29 29 * Serial number collection 30 30 ** SNs should be collected for all networked devices (all Cresnet devices and Zūm Wired devices)