... ... @@ -12,8 +12,9 @@
12 12  *** **Do** check for shorts before landing at the panel
13 13  *** **Do** land the shield with COM at the panel
14 14  *** **Do** splice through and insulate shield in the field
15 +*** **Do** use wire nuts for Cresnet splices
16 +*** **Do not** use lever-nuts for Cresnet splices
15 15  *** **Do not** leave copper showing at terminations
16 -*** **Do not** use lever-nuts (**do** use wire nuts)
17 17  *** **Do not** excessively strip back the teal-yellow jacket
18 18  ** [[Ethernet terminations>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome]] (where the EC is terminating the Ethernet)
19 19  *** **Do** use T568B Pin-Out