... ... @@ -1,1 +1,1 @@ 1 -Pre-Construction Checklist1 +Pre-Construction - Content
-
... ... @@ -1,32 +1,24 @@ 1 -The foundations of a quick, easy, and trouble-free startup are laid before thecontrolhardwareevenarrives onsite. Meeting with the electrical contractor prior to construction is important to establish a good working relationship, explain the requirements for a Crestron lighting control installation, and to exchange contact information so that any technical questions or concerns can be addressed prior to startup.1 +The foundations of a quick, easy, and trouble-free startup are laid before construction even begins. Meeting with the electrical contractor prior to construction is important to establish a good working relationship, explain the requirements for a Crestron lighting control installation, and to exchange contact information so that any technical questions or concerns can be addressed prior to startup. 2 2 3 3 Though a pre-construction site-visit may seem like a wasted expense, by communicating expectations and requirements to the electrical contractor prior to startup you are actually able to save time and headache on-site. For large jobs especially, taking the time to ensure a proper installation will save hours or days during startup. Any time spent by a technician on-site tracking down serial numbers or troubleshooting/correcting a poor installation is a waste that could have been avoided with good communication and instruction prior to and throughout the installation process. 4 4 5 - Covering these important topics with the electrical contractorduring thepre-construction phase is criticalto smooth ShowRunnerCLC™ startups.5 +Important topics to cover with the electrical contractor prior to startup: 6 6 7 -Pre-construction topics to cover: 8 - 9 -* Wiring and Installation 7 +* [[Wiring and Installation>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.WebHome]] 10 10 ** Do not power up panels until installation is complete and wiring is verified safe to connect 11 -** [[Cresnet wiring>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Cresnet Wiring Overview.WebHome]] (for jobs with Cresnet) 12 -*** (% style="color:green" %)**DO**(%%) check for shorts before landing at the panel 13 -*** (% style="color:green" %)**DO**(%%) land the shield with COM at the panel 14 -*** (% style="color:green" %)**DO**(%%) splice through and insulate shield in the field 15 -*** (% style="color:green" %)**DO**(%%) use wire nuts for Cresnet splices 16 -*** (% style="color:red" %)**DO NOT**(%%) use lever-nuts for Cresnet splices 17 -*** (% style="color:red" %)**DO NOT**(%%) leave copper showing at terminations 18 -*** (% style="color:red" %)**DO NOT**(%%) excessively strip back the teal-yellow jacket 19 -** [[Ethernet terminations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] (where the EC is terminating the Ethernet) 20 -*** (% style="color:green" %)**DO**(%%) use standard, non-passthrough RJ-45 connectors 21 -*** (% style="color:green" %)**DO**(%%) use T568B Pin-Out 22 -*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 connectors 23 -*** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length 24 -** [[Zūm Wired wiring>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]] (for Zūm Wired jobs) 25 -*** (% style="color:green" %)**DO**(%%) use standard, non-passthrough RJ-45 connectors 26 -*** (% style="color:green" %)**DO**(%%) use T568B Pin-Out 27 -*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 connectors 28 -*** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length 29 -*** (% style="color:red" %)**DO NOT**(%%) mix up Zūm Net and Zūm Link cables 9 +** [[Cresnet wiring>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Cresnet.WebHome]] (for jobs with Cresnet) 10 +*** **Do** check for shorts before landing at the panel 11 +*** **Do** land the shield with COM at the panel 12 +*** **Do** splice through and insulate shield in the field 13 +*** **Do not** leave copper showing at terminations 14 +*** **Do not** use lever-nuts (**do** use wire nuts) 15 +*** **Do not** excessively strip back the teal-yellow jacket 16 +** [[Ethernet terminations>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome]] (where the EC is terminating the Ethernet) 17 +*** **Do** use T568B Pin-Out 18 +*** **Do not** exceed 100m/328' cable length 19 +** [[Zūm Wired wiring>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome]] (for Zūm Wired jobs) 20 +*** **Do** follow the same rules as Ethernet for both Zūm Net and Zūm Link terminations/cable length 21 +*** **Do not** mix up Zūm Net and Zūm Link cables 30 30 ** Follow the load schedule 31 31 * Serial number collection 32 32 ** SNs should be collected for all networked devices (all Cresnet devices and Zūm Wired devices) ... ... @@ -36,4 +36,4 @@ 36 36 ** The easiest way to do this is to write the SNs of installed devices on the floor plans or riser diagram as they are installed 37 37 * MAC address collection (optional) 38 38 ** Collecting MAC addresses is redundant if serial numbers are provided 39 -* Establish expectations for what "ready to commission" means by sharing the [[site readiness checklist>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Preparation.Site Readiness Checklist.WebHome]]31 +* Establish expectations for what "ready to commission" means by sharing the [[site readiness checklist>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Site Readiness Checklist.WebHome]]