... ... @@ -17,12 +17,14 @@
17 17  *** (% style="color:red" %)**DO NOT**(%%) leave copper showing at terminations
18 18  *** (% style="color:red" %)**DO NOT**(%%) excessively strip back the teal-yellow jacket
19 19  ** [[Ethernet terminations>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome]] (where the EC is terminating the Ethernet)
20 +*** (% style="color:green" %)**DO**(%%) use standard, non-passthrough RJ-45 connectors
20 20  *** (% style="color:green" %)**DO**(%%) use T568B Pin-Out
21 21  *** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 terminations
22 22  *** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length
23 23  ** [[Zūm Wired wiring>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome]] (for Zūm Wired jobs)
25 +*** (% style="color:green" %)**DO**(%%) use standard, non-passthrough RJ-45 connectors
24 24  *** (% style="color:green" %)**DO**(%%) use T568B Pin-Out
25 -*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 terminations
27 +*** (% style="color:red" %)**DO NOT**(%%) use EZ-style passthrough RJ-45 connectors
26 26  *** (% style="color:red" %)**DO NOT**(%%) exceed 100m/328' cable length
27 27  *** (% style="color:red" %)**DO NOT**(%%) mix up Zūm Net and Zūm Link cables
28 28  ** Follow the load schedule