Last modified by Scott Kohlmann on 2023/04/20 22:37

From version 7.1
edited by Alexander Mott
on 2022/03/14 21:35
Change comment: There is no comment for this version
To version 12.1
edited by Mark Kohlmann
on 2022/04/15 15:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Content
... ... @@ -1,3 +1,11 @@
1 +(% class="box warningmessage" %)
2 +(((
3 +showrunner is tested against current Crestron firmware releases.  Please use at least the recommended firmware builds.
4 +3-Series: PUF 1.8001.0146
5 +4-Series: PUF 2.7000.00052.01
6 +VC-4: 2.7000.00047
7 +)))
8 +
1 1  === Notes ===
2 2  
3 3  Static IP or properly setup DHCP/DNS implementation required.
... ... @@ -21,7 +21,7 @@
21 21  
22 22  * Obtain the latest build of ShowRunner [[https:~~/~~/files.chiefintegrations.com/s/WHNzXrrZbB5jC3E>>url:https://files.chiefintegrations.com/s/WHNzXrrZbB5jC3E]]
23 23  * Set the processor’s IP Address per your network requirements
24 -* For processors with a Control Subnet (CP3N or CP4N): 
32 +* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4/ZUM-HUB4): 
25 25  ** Connect to the processor via Text Console and type "startprogafterrouter on"
26 26  *** This will force the processor to wait until the router has started before attempting to load the showrunner™ program, avoiding potential license validation issues after a power loss.
27 27  ** Networked lighting hardware should be landed on the Control Subnet
... ... @@ -29,6 +29,7 @@
29 29  ** The Control Subnet can be configured manually in the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox
30 30  *** Set routing to "Manual" with the start address and subnet size
31 31  *** E.g., a setting of "10.0.0.0/24" will have the processor at 10.0.0.1 with an IP mask of 255.255.255.0 and a default gateway and DNS server at 10.0.0.2
40 +*** 100.64.0.0/10 is a recommended range as it is unlikely to be used on any corporate network.  Processor IP will be 100.64.0.1 and default gateway/DNS will be 100.64.0.2.  Console command is: ##csrouterprefix 100.64.0.0/10##
32 32  * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting hardware.
33 33  * Double click the PUF to install ShowRunner (works best with Toolbox closed)
34 34  * Select the PUF file again if needed, connect to the processor using the pencil, and select Recheck (This verifies the need to install the program, the XPanel UI, and the Crestron App UI)
... ... @@ -53,16 +53,23 @@
53 53  *** Leave restart unchecked after transfer
54 54  *** Select “Choose File” find the license file you downloaded from the portal
55 55  *** Select “Upload”
56 -** Under “Upload New Config File”
57 -*** Select “Choose File” and find the provided SrConfig.json for this processor from the project link that was sent at project delivery.
58 -*** Select “Upload”
59 -*** Alternatively, you can drop the License.lic using Toolbox’s File Manager or your SFTP client into the NVRAM/sr folder of the processor, the SrConfig.json into NVRAM/sr/default and perform “progreset” from the processor’s console
60 -*** The program will restart
65 +** Loading Configuration
66 +*** From Configuration File
67 +**** Under “Upload New Config File”
68 +***** Select “Choose File” and find the provided SrConfig.json for this processor from the project link that was sent at project delivery.
69 +***** Select “Upload”
70 +***** Alternatively, you can drop the License.lic using Toolbox’s File Manager or your SFTP client into the NVRAM/sr folder of the processor, the SrConfig.json into NVRAM/sr/default and perform “progreset” from the processor’s console
71 +***** The program will restart
72 +*** From Backup
73 +**** Select "Restore"
74 +**** Select "Choose Backup" and find the "SRBackup.zip" of the backup you wish to restore
75 +**** Enter the secret used to create the backup.  Showrunner will upload the file and verify the secret.
76 +**** Select "Restart" to load the new configuration
61 61  * Wait about 45 seconds after loading the configuration for the program to restart completely
62 62  
63 63  === TSW Setup (Per Panel) ===
64 64  
65 -* Set the TSW 770's IP Address per your network requirements (If using a panel other than TSW-770 you will need the CI_ShowRunner-UI_v3.xx PUF)
81 +* Set the TS/TSWs IP Address per your network requirements (If using a panel other than TSW-770 you will need the CI_ShowRunner-UI_v3.xx PUF)
66 66  * Connect the PUF (CI_ShowRunner_v3.xx) to the TSW to load the UI
67 67  ** Only add CI_ShowRunner-UI_v3.xx if using touch panel other than TSW-770.  
68 68  * When finished, connect to the TSW with Text Console and type “addm 10 x.x.x.x” to link the panel to the processor (where x.x.x.x is the processor’s IP or hostname [DHCP/DNS])