Changes for page Installation and Configuration Guide for Technicians
Last modified by Scott Kohlmann on 2023/04/20 22:37
From version 13.1
edited by Mark Kohlmann
on 2022/04/15 15:24
on 2022/04/15 15:24
Change comment:
There is no comment for this version
To version 11.1
edited by Mark Kohlmann
on 2022/04/15 15:19
on 2022/04/15 15:19
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,13 +6,15 @@ 6 6 VC-4: 2.7000.00047 7 7 ))) 8 8 9 -(% class="box infomessage" id="HNotes" %) 10 -((( 11 -Notes 9 +=== Notes === 10 + 12 12 Static IP or properly setup DHCP/DNS implementation required. 12 + 13 13 Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue) 14 -))) 15 15 15 +ShowRunner is a continuously evolving product, please update to the latest firmware 16 + 17 + 16 16 **ShowRunner Installation Tutorial:** 17 17 18 18 [[https:~~/~~/www.youtube.com/watch?v=xuJ94cMCCa8>>url:https://www.youtube.com/watch?v=xuJ94cMCCa8]] ... ... @@ -27,7 +27,7 @@ 27 27 28 28 * Obtain the latest build of ShowRunner [[https:~~/~~/files.chiefintegrations.com/s/WHNzXrrZbB5jC3E>>url:https://files.chiefintegrations.com/s/WHNzXrrZbB5jC3E]] 29 29 * Set the processor’s IP Address per your network requirements 30 -* For processors with a Control Subnet (CP3N /AV3/PRO3/CP4N/AV4/PRO4/ZUM-HUB4):32 +* For processors with a Control Subnet (CP3N or CP4N): 31 31 ** Connect to the processor via Text Console and type "startprogafterrouter on" 32 32 *** This will force the processor to wait until the router has started before attempting to load the showrunner™ program, avoiding potential license validation issues after a power loss. 33 33 ** Networked lighting hardware should be landed on the Control Subnet ... ... @@ -35,7 +35,6 @@ 35 35 ** The Control Subnet can be configured manually in the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox 36 36 *** Set routing to "Manual" with the start address and subnet size 37 37 *** E.g., a setting of "10.0.0.0/24" will have the processor at 10.0.0.1 with an IP mask of 255.255.255.0 and a default gateway and DNS server at 10.0.0.2 38 -*** 100.64.0.0/10 is a recommended range as it is unlikely to be used on any corporate network. Processor IP will be 100.64.0.1 and default gateway/DNS will be 100.64.0.2. Console command is: ##csrouterprefix 100.64.0.0/10## 39 39 * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting hardware. 40 40 * Double click the PUF to install ShowRunner (works best with Toolbox closed) 41 41 * Select the PUF file again if needed, connect to the processor using the pencil, and select Recheck (This verifies the need to install the program, the XPanel UI, and the Crestron App UI) ... ... @@ -76,7 +76,7 @@ 76 76 77 77 === TSW Setup (Per Panel) === 78 78 79 -* Set the TS /TSWs IP Address per your network requirements (If using a panel other than TSW-770 you will need the CI_ShowRunner-UI_v3.xx PUF)80 +* Set the TSW 770's IP Address per your network requirements (If using a panel other than TSW-770 you will need the CI_ShowRunner-UI_v3.xx PUF) 80 80 * Connect the PUF (CI_ShowRunner_v3.xx) to the TSW to load the UI 81 81 ** Only add CI_ShowRunner-UI_v3.xx if using touch panel other than TSW-770. 82 82 * When finished, connect to the TSW with Text Console and type “addm 10 x.x.x.x” to link the panel to the processor (where x.x.x.x is the processor’s IP or hostname [DHCP/DNS])