Changes for page Steinel GLA-IR-QUATTRO-HD-COM1-24
Last modified by Alexander Mott on 2022/09/20 17:22
From version 5.1
edited by Alexander Mott
on 2020/05/15 16:42
on 2020/05/15 16:42
Change comment:
There is no comment for this version
To version 2.2
edited by Craig Lewis
on 2020/05/15 16:32
on 2020/05/15 16:32
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - GLA-IR-QUATTRO-HD-COM1-241 +Steinel Sensors - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. alexander\.mott@chiefintegrations\.com1 +XWiki.craig\.lewis@chiefintegrations\.com - Content
-
... ... @@ -1,4 +1,4 @@ 1 -The GLA-IR-QUATTRO-HD-COM1-24 is a ceiling-mounted occupancy sensor .TheGLA-IR-QUATTRO-HD-COM1-24can be used in standalone applications when paired with a GLPP, GLPAC, or GL-IPAC.1 +The GLA-IR-QUATTRO-HD-COM1-24 is a ceiling-mounted occupancy sensor designed to provide coverage for areas up to 2,000 square feet. The sensor utilizes both passive infrared (PIR) and ultrasonic (US) motion sensors to allow reliable motion detection. The GLS-ODT-C-NS can be used in standalone applications when paired with a GLPP, GLPAC, or GL-IPAC. 2 2 3 3 === Note on GLA-IR-QUATTRO-HD-COM1-24 Power Draw === 4 4 ... ... @@ -8,7 +8,8 @@ 8 8 9 9 === Detailed Analysis === 10 10 11 -The below measurements were taken with GLA-IR-QUATTRO-HD-COM1-24 attached to a GLPP-1DIMFLV2CN-PM with ~~1’ of wire using a Pokit portable oscilloscope in line to capture the current. On startup,thesensorbriefly draws60mAbeforedroppingto~~20mAafter 50ms. 20mA average consumption is fairly stable for the remainder of the sensor’s runtime. Similar measurements were obtained with a Fluke 189 DMM so we know this Pokit capture is accurate. Alternative measurements were taken with an HP 6632A DC power supply as the 24VDC power source and similar readings were produced and confirmed by the power supply’s internal meter.11 +The below measurements were taken with GLA-IR-QUATTRO-HD-COM1-24 attached to a GLPP-1DIMFLV2CN-PM with ~~1’ of wire using a Pokit portable oscilloscope in line to capture the current. The initial soft start (~~50ms) is followed by full operation which draws ~~20mA. 20mA average consumption is fairly stable for the remainder of the sensor’s runtime. Similar measurements were obtained with a Fluke 189 DMM so we know this Pokit capture is accurate. Alternative measurements were taken with an HP 6632A DC power supply as the 24VDC power source and similar readings were produced and confirmed by the power supply’s internal meter. 12 12 13 +Note, the Steinel IR Quattro HD sensors draw ~~60mA at startup but within 50ms drop down to 20mA steady state and remain there. The Steinel sensors also have better coverage in our experience. 13 13 14 14 [[image:image-20200515092057-1.png]]