Changes for page GLS-ODT-C-NS and CN
Last modified by Alexander Mott on 2021/12/08 00:15
From version 3.1
edited by Craig Lewis
on 2020/05/14 18:13
on 2020/05/14 18:13
Change comment:
There is no comment for this version
To version 4.1
edited by Alexander Mott
on 2020/05/15 15:48
on 2020/05/15 15:48
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. craig\.lewis@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,16 +1,20 @@ 1 - Iwent through a similar analysis with our team’sownreporting of issues with 3GLS-ODT-C-CNson projects. Don’t knowif theproblemis due to a material change mid-production or has alwaysbeen incorrect but it is problem with shipping hardware.1 +=== Note on GLS-ODT-C-NS Power Draw === 2 2 3 +The listed power draw for GLS-ODT-C-NS sensors is 45mA at 24VDC, however Chief Integrations' testing with shipped hardware shows the real-world power draw to be closer to 60mA. While GLPP modules are able to provide 150mA at 24VDC for sensors, this is insufficient for real-world applications involving more than two GLS-ODT-C-NS occupancy sensors. 3 3 4 - Crestronhashad the specs on theGLS-ODT-C-NS sensors wrong and wehaven’tbeenableto get them corrected. The sensorsactually draw ~~60mA. We’ve done a number of jobs with GLPPs that don’t perform correctly becauseof the over-current situationcreated by 3ormoreGLS-ODT-C-CNs attachedto a GLPP. LastI heardCrestron tech support was acknowledging3 sensors wastoo many on the GLPP and was advisingTR-100sor other external power if more than2sensorswere used.5 +As such, Chief Integrations recommends adding a TR-100 or other external power supply if more than two sensors are required to be added to one GLPP. 5 5 7 +=== Detailed Analysis === 6 6 7 - Here's an analysis we’ve performedwith our own inventoryofhardware:9 +The below measurements were taken with GLS-ODT-C-NS (SN 15772519) attached to a GLPP-1DIMFLV2CN-PM (SN 17386110) with ~~1’ of wire using a Pokit portable oscilloscope in line to capture the current. The initial soft start (~~270ms) is followed by full operation which draws ~~60mA. 60mA average consumption is fairly stable for the remainder of the sensor’s runtime. PIR, US A and B are enabled as are the LEDs on this unit. Turning off some of those functions may reduce the current consumption but we have not measured them. Similar measurements were obtained with a Fluke 189 DMM so we know this Pokit capture is accurate. Alternative measurements were taken with an HP 6632A DC power supply as the 24VDC power source and similar readings were produced and confirmed by the power supply’s internal meter. 8 8 9 -Below measurements were taken with GLS-ODT-C-NS (SN 15772519) attached to GLPP-1DIMFLV2CN-PM (SN 17386110) with ~~1’ of wire length with a Pokit portable oscilloscope in line to capture the current. The initial soft start (~~270ms) is followed by full operation which draws ~~60mA. 60mA average consumption is fairly stable for the remainder of the sensor’s runtime. PIR , US A and B are enabled as are the LEDs on this unit. Turning off some of those functions may reduce the current consumption but we have not measured them. Similar measurements were obtained with a Fluke 189 DMM so we know this Pokit capture is accurate. Alternative measurements were taken with an HP 6632A DC power supply as the 24VDC power source and similar readings were produced and confirmed by the power supply’s internal meter. 10 - 11 11 [[image:image-20200514111237-1.jpeg]] 12 12 13 +//GLS-ODT-C-NS current draw readings.// 13 13 14 -Note, the Steinel IR Quattro HD sensors draw ~~60mA at startup but within 50ms drop down to 20mA steady state and remain there. The Steinel sensors also have better coverage in our experience. 15 15 16 +The Steinel IR Quattro HD sensors draw ~~60mA at startup but within 50ms drop down to 20mA steady state and remain there. The Steinel sensors also have better coverage in our experience. 17 + 16 16 [[image:image-20200514111237-2.png]] 19 + 20 +//GLA-IR-QUATTRO-1COM-24 current draw readings.//