Changes for page **Starting Up Zūm Wired with SHOWRUNNER™
Last modified by Alexander Mott on 2023/12/13 19:15
From version 5.1
edited by Alexander Mott
on 2023/03/28 17:50
on 2023/03/28 17:50
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,6 +18,12 @@ 18 18 See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. 19 19 See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details. 20 20 21 += Zūm Discovery = 22 + 23 +SHOWRUNNER™ includes a Zum Wired Discovery feature that makes it easy to import Zūm Rooms that have been configured in App Mode into an existing SHOWRUNNER™ configuration. The process for starting up a system using this method is the same as starting up any other networked installation in App Mode, but with the added steps of installing SHOWRUNNER and importing the Zum Rooms 24 + 25 += SHOWRUNNER™ Complete Control = 26 + 21 21 = Start-Up Guide = 22 22 23 23 Lorem ... ... @@ -47,14 +47,22 @@ 47 47 ** will take up to several minutes per room, but will be able to do up to 10 rooms simultaneously 48 48 ** devices will reboot, possibly multiple times 49 49 ** check loadscript manager for any failures and re-run script for those devices if necessary (a rebooting zumnet box will temporarily disrupt online status for downstream zumnet jboxs and potentially interrupt the firmware update) 56 +* run device discovery again to confirm that all zumnet boxes were updated 57 +** zumnet boxes update last, so if a zumnet jbox is updated then this means that all of the zumlink devices that were online have also been updated 58 +* if app mode backup is desired, configure the boxes using the app now 50 50 * run "ip config (def. hostname)" loadscript to update device IP-IDs and hostnames 51 51 ** devices will reboot 52 52 ** devices will now have new hostnames, so any further loadscripts should use (new hostname) versions 62 +* run "cnet mode (def. hostname)" loadscript to put devices into CNET mode 63 +** if app mode backup is desired, also run "autoswitch enable (def. hostname)" loadscript 64 +** devices will reboot 53 53 * if using a processor without control subnet, run the "static ip config (new hostname)" script 54 54 ** this loadscript is necessary, as the showrunner DHCP server is only intended for commissioning. It must always be manually started after program restart and should not be used in production 55 55 ** (**will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json**) 56 56 * once done, commission job essentially as normal showrunner job 57 57 ** (**sr commissioning guide is incomplete**) 70 +** connect to each zumnet jbox and address zumlink devices per the takeoff 71 +*** if devices are not online, then troubleshoot why and update firmware through device tree view once they are online 58 58 ** occ timeouts can be adjusted through UI; other settings (ie reach) should be adjusted through app 59 59 ** photocells etc are set up through UI 60 60 ** loads teseted and verified through UI; can be moved around between controllers as necessary ... ... @@ -61,5 +61,6 @@ 61 61 *** loads don't need to be in the same room as the zumnet that controls them 62 62 ** keypads can use standard SR types or be fully customized 63 63 ** set up schedule, etc. 78 +* once done, save and back up configuration file 64 64 ))) 65 65 )))