Changes for page **Starting Up Zūm Wired with SHOWRUNNER™
Last modified by Alexander Mott on 2023/12/13 19:15
From version 4.1
edited by Alexander Mott
on 2023/03/28 15:14
on 2023/03/28 15:14
Change comment:
There is no comment for this version
To version 2.1
edited by Alexander Mott
on 2023/03/27 21:30
on 2023/03/27 21:30
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,36 +21,4 @@ 21 21 = Start-Up Guide = 22 22 23 23 Lorem 24 - 25 -(% class="box warningmessage" %) 26 -((( 27 -cross reference/update to old [[zumnet startup>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]? 28 - 29 -basic steps: 30 -* configure your processor per chief's startup guide 31 -* get all zumnet jbox online 32 -** use built in dhcp from processor control subnet 33 -** if using proc without control subnet, use showrunner [[dhcp>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]] 34 -** (**will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json**) 35 -* use crestron toolbox device discovery to create a [[Device Summary>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoDeviceSummary"]] 36 -* use chief tools tm tool to generate various zum wired load scripts 37 -** (need to determine exact process for this; will need to add IP-ID and new hostname to device summary somehow) 38 -** (will likely generate two versions of the loadscripts; one connecting by default hostname and one connecting by new hostname) 39 -** (intend to require SR license for zwired LS generator, if only to get the proc mac address) 40 -* if firmware is old, run "zwms master/zum (def. hostname)" loadscript to make all ZUMNET JBOX primary and in app mode in order to enable discovery of devices on zumlink 41 -** devices will reboot 42 -** per crestron, 1.0006.00012 and newer ship in primary mode (**tbd if they will ship in app mode?**) 43 -* connect to a few devices in device discovery tool to ensure that all zumlink devices were automatically readdressed and there are no conflicting cids 44 -** firmware 1.0001.00081 is new enough that this works correctly 45 -* run "fw update (def. hostname)" loadscript to update the fw for all devices 46 -** will take up to several minutes per room, but will be able to do up to 10 rooms simultaneously 47 -** devices will reboot, possibly multiple times 48 -** check loadscript manager for any failures and re-run script for those devices if necessary (a rebooting zumnet box will temporarily disrupt online status for downstream zumnet jboxs and potentially interrupt the firmware update) 49 -* run "ip config (def. hostname)" loadscript to update device IP-IDs and hostnames 50 -** devices will reboot 51 -** devices will now have new hostnames, so any further loadscripts should use (new hostname) versions 52 -* if using a processor without control subnet, run the "static ip config (new hostname)" script 53 -** this loadscript is necessary, as the showrunner DHCP server is only intended for commissioning. It must always be manually started after program restart and should not be used in production 54 -** (**will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json**) 55 55 ))) 56 -)))