Changes for page **Starting Up Zūm Wired with SHOWRUNNER™
Last modified by Alexander Mott on 2023/12/13 19:15
From version 18.1
edited by Alexander Mott
on 2023/03/29 23:15
on 2023/03/29 23:15
Change comment:
Uploaded new attachment "1680131728246-538.png", version {1}
To version 24.1
edited by Alexander Mott
on 2023/03/29 23:17
on 2023/03/29 23:17
Change comment:
Deleted image "1680131641698-670.png"
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,24 +14,36 @@ 14 14 ))) 15 15 16 16 SHOWRUNNER™ includes a Zūm Wired Discovery feature that makes it easy to import Zūm Rooms that have been configured in App Mode into an existing SHOWRUNNER™ configuration. The process for starting up a system using this method is the same as starting up any other networked installation in App Mode, but with the added steps of installing SHOWRUNNER and importing Zūm Rooms into the configuration. 17 + 17 17 Installing SHOWRUNNER™ on different processors is covered in our [[startup pages>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]], while importing Zūm Rooms is covered in the [[Zūm Wired Discovery>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.Zūm Discovery.WebHome]] page. 18 18 19 19 = CNET Mode (SHOWRUNNER™ Total Control) = 20 20 21 -Lorem 22 +Using SHOWRUNNER™ to control a networked Zūm Wired installation with ZUMNET-JBOXs running in CNET mode is the recommended way of using SHOWRUNNER™ with Zūm Wired. This is also the only way to gain control of legacy Cresnet devices (such as GL-EXP-DIMU-CN, C2N-IO, and GLS-PART-CN) that are connected to a ZUMNET-JBOX, as these Cresnet devices are not recognized or supported by the Crestron Zūm App. 22 22 23 23 (% class="box warningmessage" %) 24 24 ((( 25 -cross reference/update to old [[zumnet startup>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]? 26 +steps subject to change pending finalization of chief zum wired loadscript tool 27 +))) 26 26 27 - basicsteps:29 +The steps for configuring a networked Zūm Wired installation with SHOWRUNNER™ are: 28 28 29 -* configure your processor per chief's startup guide 30 -* get all zumnet jbox online 31 -** use built in dhcp from processor control subnet 32 -** if using proc without control subnet, use showrunner [[dhcp>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]] 33 -** (**will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json**) 34 -* use crestron toolbox device discovery to create a [[Device Summary>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoDeviceSummary"]] 31 +1. Install SHOWRUNNER™ and configure the processor per our [[startup guides>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] 32 +1*. If using a processor without a dedicated Control Subnet, follow the [[additional steps detailed below>>doc:Design Guide.Hardware Design Guide.Crestron Zum Wired.Starting Up Zum Wired with SHOWRUNNER.WebHome||anchor="HToolsforStaticallyConfiguredLightingNetworks"]] 33 +1. Verify that all expected ZUMNET-JBOX-* devices are reporting online using the Device Discovery tool in Toolbox 34 +1*. Your laptop and the ZUMNET-JBOXs should all be connected to the Control Subnet 35 +1*. If there are missing ZUMNET-JBOXs, verify with the EC that the devices are powered and that the Zūm Net cabling is correct 36 +1*. Recall that any ZUMNET-JBOX that is unpowered or disconnected will prevent downstream ZUMNET-JBOXs from coming online 37 +1. Once all hardware is online, use the [[Device Discovery Tool>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HDeviceDiscoveryTool"]] in Toolbox to [[export a Device Summary>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoDeviceSummary"]] file 38 +1*. These steps can still be followed even if not all the hardware is online 39 +1*. If not all the hardware is online, then these steps will need to be repeated and the loadscripts run just for the previously offline devices 40 +1*. Alternatively, if there are only a few previously offline devices, then they can be [[configured and updated manually>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]] 41 +1. Add columns for hostname ("Host", J) and IP-ID ("IP-ID", K) as shown below[[image:1680131811288-423.png]] 42 +1. Fill out these columns for each of the ZUMNET-JBOXs in the device summary 43 +1*. If there is no default gateway or DNS, use the processor's IP address instead 44 +1*. If this information has already been filled out in the SHOWRUNNER™ Takeoff IP Table sheet, then it is easy to copy/paste from the takeoff into the Device Summary .csv by sorting and filtering the two documents by MAC address 45 + 46 +* use crestron toolbox device discovery to create a [[Device Summary>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HDeviceDiscoveryTool"]] 35 35 * use chief tools tm tool to generate various zum wired load scripts 36 36 ** (need to determine exact process for this; will need to add IP-ID and new hostname to device summary somehow) 37 37 ** (will likely generate two versions of the loadscripts; one connecting by default hostname and one connecting by new hostname) ... ... @@ -68,7 +68,6 @@ 68 68 ** keypads can use standard SR types or be fully customized 69 69 ** set up schedule, etc. 70 70 * once done, save and back up configuration file 71 -))) 72 72 73 73 = Tools for Statically Configured Lighting Networks = 74 74 ... ... @@ -80,7 +80,20 @@ 80 80 81 81 1. [[Configure the static IP address>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HIPConfiguration"]] for the processor and [[install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HProgramLoad"]] 82 82 1. Use SHOWRUNNER™'s built in [[DHCP server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]] 83 -** If it you want to use specific static IP addresses for specific ZUMNET-JBOXs, use the SHOWRUNNER™ UI and set the DHCP range outside of the range you intend to use for the ZUMNET-JBOXs 84 -** If arbitrary static IP addresses are acceptable, then use the default IP address range 85 -1. Proceed with the standard [[CNET Mode>>doc:Hardware Design Guide.Crestron Zum Wired.Starting Up Zum Wired with SHOWRUNNER.WebHome||anchor="HIPConfiguration"]] start-up procedure 94 +1*. If you want to use specific static IP addresses for specific ZUMNET-JBOXs, use the SHOWRUNNER™ UI and set the DHCP range outside of the range you intend to use for the ZUMNET-JBOXs 95 +1*. If arbitrary static IP addresses are acceptable, then use the default IP address range 96 +1. Proceed with the standard [[CNET Mode>>doc:Design Guide.Hardware Design Guide.Crestron Zum Wired.Starting Up Zum Wired with SHOWRUNNER.WebHome||anchor="HCNETMode28SHOWRUNNER2122TotalControl29"]] start-up procedure from step 2 97 +1. Once the standard start-up procedure has been completed, [[export a new Device Summary>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoDeviceSummary"]] file 98 +1. Change the Device Summary filetype to ".csv" and open in Microsoft Excel 99 +1. Add columns for hostname ("Host", J), IP-ID ("IP-ID", K), static IP address ("IPA", L), static IP subnet mask ("IPM", M), default gateway ("DEFR", N), and domain name server ("DNS", O) as shown below[[image:1680131807403-927.png]] 100 +1. Fill out these columns for each of the ZUMNET-JBOXs in the device summary 101 +1*. If there is no default gateway or DNS, use the processor's IP address instead 102 +1*. "IP-ID" column is optional 103 +1*. If this information has already been filled out in the SHOWRUNNER™ Takeoff IP Table sheet, then it is easy to copy/paste from the takeoff into the Device Summary .csv by sorting and filtering the two documents by MAC address 104 +1. Use the modified Device Summary file and Chief Integrations' Zūm Wired Loadscript Generator Tool to generate a loadscript that connects to devices by their hostname and sets their static IP settings 105 +1*. Up to 10 devices can be configured simultaneously 106 +1*. Devices will reboot once this script is run 107 +1. Verify that all devices report completing successfully in the Loadscript Manager tool 108 +1. If desired, export a new Device Summary file as a record that this step was completed successfully 109 +1. If desired, disable the processor's DHCP service (the service will not resume if the processor reboots or the program restarts) 86 86 )))
- 1680129701821-479.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.8 KB - Content
- 1680131641698-670.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.0 KB - Content
- 1680131811288-423.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.8 KB - Content