Changes for page **Starting Up Zūm Wired with SHOWRUNNER™
Last modified by Alexander Mott on 2023/12/13 19:15
From version 1.1
edited by Alexander Mott
on 2023/03/27 21:28
on 2023/03/27 21:28
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Hidden
-
... ... @@ -1,1 +1,1 @@ 1 - false1 +true - Content
-
... ... @@ -2,35 +2,79 @@ 2 2 ((( 3 3 n/a 4 4 ))) 5 + 5 5 (% class="box warningmessage" %) 6 6 ((( 7 7 n/a 8 8 ))) 10 + 9 9 {{box cssClass="floatinginfobox" title="**CONTENTS**"}} 10 10 {{toc/}} 11 11 {{/box}} 14 + 12 12 (% class="row" %) 13 13 ((( 14 14 Lorem 15 15 See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. 16 16 See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details. 17 -= The SHOWRUNNER™ Advantage = 20 + 21 += Zūm Discovery = 22 + 23 +SHOWRUNNER™ includes a Zum Wired Discovery feature that makes it easy to import Zūm Rooms that have been configured in App Mode into an existing SHOWRUNNER™ configuration. The process for starting up a system using this method is the same as starting up any other networked installation in App Mode, but with the added steps of installing SHOWRUNNER and importing the Zum Rooms 24 + 25 += SHOWRUNNER™ Complete Control = 26 + 27 += Start-Up Guide = 28 + 18 18 Lorem 19 -== Ease of Start-Up == 20 -Lorem 21 -== Exclusive Features == 22 -Lorem 23 -== Suitable for a Range of Applications == 24 -Lorem 25 -== Support and Continued Development == 26 -Lorem 27 -= Best Practices for Zūm Wired with SHOWRUNNER™ = 28 -Though it is possible to design a Zūm Wired system to use the standard ZUM-HUB4 program and then import rooms from SHOWRUNNER™, it is not recommended as it adds the expense of a custom program without taking advantage of any of the added functionality that SHOWRUNNER™ has to offer. 29 -Instead, to take full advantage of everything that SHOWRUNNER™ has to offer, follow these best practices: 30 -* Design the system to use SHOWRUNNER™ as the main program 31 -* Set ZUMNET-JBOX-* devices in CNET mode after any App-specific configurations have been made 32 -Zūm 33 -SHOWRUNNER™ 34 -= Feature Comparison Table = 35 -Lorem 30 + 31 +(% class="box warningmessage" %) 32 +((( 33 +cross reference/update to old [[zumnet startup>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]? 34 + 35 +basic steps: 36 + 37 +* configure your processor per chief's startup guide 38 +* get all zumnet jbox online 39 +** use built in dhcp from processor control subnet 40 +** if using proc without control subnet, use showrunner [[dhcp>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]] 41 +** (**will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json**) 42 +* use crestron toolbox device discovery to create a [[Device Summary>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoDeviceSummary"]] 43 +* use chief tools tm tool to generate various zum wired load scripts 44 +** (need to determine exact process for this; will need to add IP-ID and new hostname to device summary somehow) 45 +** (will likely generate two versions of the loadscripts; one connecting by default hostname and one connecting by new hostname) 46 +** (intend to require SR license for zwired LS generator, if only to get the proc mac address) 47 +* if firmware is old, run "zwms master/zum (def. hostname)" loadscript to make all ZUMNET JBOX primary and in app mode in order to enable discovery of devices on zumlink 48 +** devices will reboot 49 +** per crestron, 1.0006.00012 and newer ship in primary mode (**tbd if they will ship in app mode?**) 50 +* connect to a few devices in device discovery tool to ensure that all zumlink devices were automatically readdressed and there are no conflicting cids 51 +** firmware 1.0001.00081 is new enough that this works correctly 52 +* run "fw update (def. hostname)" loadscript to update the fw for all devices 53 +** will take up to several minutes per room, but will be able to do up to 10 rooms simultaneously 54 +** devices will reboot, possibly multiple times 55 +** check loadscript manager for any failures and re-run script for those devices if necessary (a rebooting zumnet box will temporarily disrupt online status for downstream zumnet jboxs and potentially interrupt the firmware update) 56 +* run device discovery again to confirm that all zumnet boxes were updated 57 +** zumnet boxes update last, so if a zumnet jbox is updated then this means that all of the zumlink devices that were online have also been updated 58 +* if app mode backup is desired, configure the boxes using the app now 59 +* run "ip config (def. hostname)" loadscript to update device IP-IDs and hostnames 60 +** devices will reboot 61 +** devices will now have new hostnames, so any further loadscripts should use (new hostname) versions 62 +* run "cnet mode (def. hostname)" loadscript to put devices into CNET mode 63 +** if app mode backup is desired, also run "autoswitch enable (def. hostname)" loadscript 64 +** devices will reboot 65 +* if using a processor without control subnet, run the "static ip config (new hostname)" script 66 +** this loadscript is necessary, as the showrunner DHCP server is only intended for commissioning. It must always be manually started after program restart and should not be used in production 67 +** (**will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json**) 68 +* once done, commission job essentially as normal showrunner job 69 +** (**sr commissioning guide is incomplete**) 70 +** connect to each zumnet jbox and address zumlink devices per the takeoff 71 +*** if devices are not online, then troubleshoot why and update firmware through device tree view once they are online 72 +** occ timeouts can be adjusted through UI; other settings (ie reach) should be adjusted through app 73 +** photocells etc are set up through UI 74 +** loads teseted and verified through UI; can be moved around between controllers as necessary 75 +*** loads don't need to be in the same room as the zumnet that controls them 76 +** keypads can use standard SR types or be fully customized 77 +** set up schedule, etc. 78 +* once done, save and back up configuration file 36 36 ))) 80 +)))