Changes for page **General Overview and Design Considerations
Last modified by Alexander Mott on 2023/12/08 18:37
To version 14.10
edited by Alexander Mott
on 2023/03/27 19:32
on 2023/03/27 19:32
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -88,8 +88,26 @@ 88 88 89 89 == Standalone == 90 90 91 - Lorem91 +Completely standalone Zūm Wired designs are possible, but they have some important benefits and drawbacks to consider. 92 92 93 +Some benefits of a standalone Zūm Wired system are: 94 + 95 +* Reduced installation time and cost as no Zūm Net cabling is required between rooms 96 +* Reduced hardware cost as no ZUM-HUB4 or networking hardware is required 97 + 98 +Some drawbacks of a standalone Zūm Wired system are: 99 + 100 +* As of 2/2023, ZUMNET-JBOX-* devices ship with factory settings that are incompatible with an App only startup, resulting in extra expense to configure and update devices prior to installation or extra time spent during startup to accomplish these tasks post-installation: 101 +** ZUMNET-JBOX-* devices must be manually set to Zūm App mode 102 +** ZUMNET-JBOX-* devices must be manually set to Primary mode 103 +** Updating firmware with the Crestron Zūm App is not possible with out-of-the-box firmware and must be initially done through Toolbox 104 +* ZUMNET-JBOX-* devices can only be connected to and configured via the App if there is a ZUMLINK-KP on their Zūm Link bus. During start-up, a technician must bring a ZUMLINK-KP with them to connect to the ZUMNET-JBOX for any rooms that were not designed to have a ZUMLINK-KP 105 +* No scheduling capabilities 106 +* No cross-room control capabilities (i.e., ZUMLINK-* keypads and occupancy sensors are restricted to controlling loads that are attached to the same ZUMNET-JBOX as they are) 107 +* No support for Cresnet devices 108 +* No support for third-party integrations beyond the override contact-closure relay at each ZUMNET/ZUMLINK-JBOX and the relay output of any *-RLY model occupancy sensors 109 +* No support for DMX control 110 + 93 93 == Networked == 94 94 95 95 Lorem ... ... @@ -96,20 +96,26 @@ 96 96 97 97 === Networked with Default Program === 98 98 99 - Lorem117 +Some benefits of using the default program are: 100 100 101 - ===Networkedwith Custom Program ===119 +* 102 102 103 - Lorem121 +Some drawbacks of using the default program are: 104 104 105 -== Start-Up Considerations == 123 +* Requires a ZUM-HUB4 processor 124 +* Limited support for Cresnet devices on the Zūm Link bus (n**o support?**) 125 +* Limited scheduling capabilities 106 106 107 - Lorem127 +=== Networked with Custom Program === 108 108 109 - == ProcessorSelectionforNetworkedSystems==129 +Some benefits of using a custom program such as SHOWRUNNER™ are: 110 110 111 - Lorem131 +* 112 112 133 +Some drawbacks of using a custom program such as SHOWRUNNER™ are: 134 + 135 +* 136 + 113 113 = Hardware Design Limitations = 114 114 115 115 There are a handful of limitations to keep in mind when designing Zūm Wired systems, with different restrictions applying to Zūm Net and Zūm Link: