Changes for page **General Overview and Design Considerations
Last modified by Alexander Mott on 2023/12/08 18:37
From version 11.1
edited by Alexander Mott
on 2023/03/24 19:24
on 2023/03/24 19:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,53 +4,46 @@ 4 4 5 5 (% class="row" %) 6 6 ((( 7 -Crestron Zūm Wired is a system thathas variousglobal andlocal control options. Zūm Wireduses industry standard dimming protocols(DALI, 0-10V, and phase dimming) and advanced sensorsto provide automated control of a buildingor facility's lighting.With certain designs, it is also possible to integrate control over DMX fixtures, building management systems, and other third-party devices (such as motorized shades and HVAC).7 +Crestron Zūm Wired is a distributed lighting control platform that utilizes advanced sensors and industry standard dimming protocols to provide automated control of a building's lighting. 8 8 9 -The purpose of this article is to explain various important concepts that must be understood in order to design a system that meets the requirements of all project stakeholders. 10 10 11 -= System Overview and Hardware Modes = 12 12 13 -Zūm Wired systems consist of ZUMNET-JBOX-* room controllers and a number of connected ZUMLINK-* devices. ZUMLINK-* devices can be ZUMLINK-JBOX-* load controllers, ZUMLINK-OCC-* presence detectors, or ZUMLINK-KP-R-W keypads (wall switches). ZUMNET-JBOX-* and ZUMLINK-JBOX-* devices have additional inputs for third-party presence detectors, 0-10V analog photocells, and contact-closure local override. 14 14 15 -== App Mode == 16 16 17 -Lorem 18 18 19 -== CNET Mode == 20 20 21 -Lorem 22 22 23 -== Primary vs Secondary Mode == 24 24 25 -(% class="box in fomessage" %)17 +(% class="box warningmessage" %) 26 26 ((( 27 - Note: the terminology usedfor these modeswasmodified in .puf firmwarev1.03.27 (device firmware v1.002.00026). Hardware delivered witholderfirmware will require the use of differentcommands to change modes during start-up.19 +Add more to intro 28 28 ))) 29 29 30 - ZUMNET-JBOX-*devices can be set to be eitherthe Primary room controller or a Secondary load controller.There must only be one Primary ZUMNET-JBOXon a given Zūm Link bus, andin a networkedsystemthe Primary ZUMNET-JBOX is the one that should be connected to the Zūm Net.22 += Hardware Modes = 31 31 32 -* In Primary mode, the ZUMNET-JBOX acts as the Zūm Link host, and is able to detect all connected Zūm Link devices. If connected to in Crestron Toolbox, a Primary ZUMNET-JBOX can be used to view and manually address any connected ZUMLINK-* devices. While in App mode, a ZUMNET-JBOX in Primary mode is the logical room controller for the space and is the device that should be used for configuration via the Zūm App. 33 -* In Secondary mode, the ZUMNET-JBOX acts as if it were a ZUMLINK-JBOX. It does not process any room control logic, and when connected to via Crestron Toolbox it will not be able to see any other ZUMLINK-* devices. Using Secondary mode is rare, and should only be used in cases where a spare ZUMNET-JBOX is being used to add a load to another ZUMNET-JBOX or replace a ZUMLINK-JBOX that has been lost or damaged. 24 +Lorem 34 34 35 - Asof February, 2023,Crestron is shipping all ZUMNET-JBOX-*preconfiguredin Secondarymode, though this may change in the future.26 +== CNET Mode == 36 36 37 - == Security ==28 +Lorem 38 38 30 +== App Mode == 31 + 39 39 Lorem 40 40 34 +== Primary vs Secondary == 35 + 36 +Lorem 37 + 41 41 = Control Paradigms = 42 42 43 -Designs for Zūm Wired systems a re broadlycategorized as either "standalone" or "networked"designs.Both standaloneand networked systemsshould be designed with one ZUMNET-JBOX-* per room or logical controlspaceconnectedto a number of ZUMLINK-*deviceswithinhatsamespace. In networkedsystems, thereis also a control processor whichprovides centralized control of the entire system.ZUMNET-JBOX-* must be daisy-chained togetherwith ZūmNetand then connected backto theprocessor. In standaloneapplications, thereisnoprocessor and no Zūm Net cablingconnecting different rooms to each other.40 +Designs for Zūm Wired systems can be broadly described as being either "standalone" or "networked". Networked systems can be further subdivided into "Networked with Default Program" or "Networked with Custom Program". 44 44 42 +Depending on which control paradigm is selected, there are varied impacts to cost of hardware, cost and complexity of start-up, ease of maintenance, and control capabilities. 45 45 46 -The difference between the two is that in a networked system there will be Zūm Net cabling connecting each ZUMNET-JBOX-* 47 47 48 48 In standalone applications, each room has one ZUMNET-JBOX-* with a number of connected ZUMLINK-* devices. There is no Zūm Net connecting different rooms, 49 49 50 -Networked systems can be further subdivided into "Networked with Default Program" or "Networked with Custom Program". 51 - 52 -Depending on which control paradigm is selected, there will be various impacts to the hardware cost, start-up cost, start-up complexity, ease of maintenance, control capabilities, integration with third-party systems, available user interfaces, and the ability to meet a provided sequence of operations. 53 - 54 54 == Standalone == 55 55 56 56 Lorem