Changes for page **General Overview and Design Considerations
Last modified by Alexander Mott on 2023/12/08 18:37
To version 13.1
edited by Alexander Mott
on 2023/03/24 20:09
on 2023/03/24 20:09
Change comment:
Uploaded new attachment "1679688568997-208.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -*Design Considerations 1 +*General Overview and Design Considerations - Content
-
... ... @@ -12,6 +12,8 @@ 12 12 13 13 Zūm Wired systems consist of ZUMNET-JBOX-* room controllers and a number of connected ZUMLINK-* devices. ZUMLINK-* devices can be ZUMLINK-JBOX-* load controllers, ZUMLINK-OCC-* presence detectors, or ZUMLINK-KP-R-W keypads (wall switches). ZUMNET-JBOX-* and ZUMLINK-JBOX-* devices have additional inputs for third-party presence detectors, 0-10V analog photocells, and contact-closure local override. 14 14 15 +ZUMNET-JBOX-* room controllers can be operated in App mode or CNET mode, with an additional setting to be either the Primary room controller or a Secondary load controller. 16 + 15 15 == App Mode == 16 16 17 17 Lorem ... ... @@ -24,18 +24,19 @@ 24 24 25 25 (% class="box infomessage" %) 26 26 ((( 27 -Note th atprior to .puf firmware v1.03.27 (device firmware v1.002.00026), thesewere referredtoas "master"and"slave" mode. As of February, 2023, ZUMNET-JBOX-* arestill shipping onthisolder firmware,andsothe older commandsmustbe used toinitiallychangethemodeprior to updatingdevice firmware.29 +Note: the terminology used for these modes was modified in .puf firmware v1.03.27 (device firmware v1.002.00026). Hardware delivered with older firmware will require the use of different commands to change modes during start-up. 28 28 ))) 29 29 30 -ZUMNET-JBOX-* devices can be set to be either the primary room controller or asecondary load controller.As ofFebruary,2023, ZUMNET-JBOX-*32 +ZUMNET-JBOX-* devices can be set to be either the Primary room controller or a Secondary load controller. There must only be one Primary ZUMNET-JBOX on a given Zūm Link bus, and in a networked system the Primary ZUMNET-JBOX is the one that should be connected to the Zūm Net. 31 31 32 -* In Primary 34 +* In Primary mode, the ZUMNET-JBOX acts as the Zūm Link host, and is able to detect all connected Zūm Link devices. If connected to in Crestron Toolbox, a Primary ZUMNET-JBOX can be used to view and manually address any connected ZUMLINK-* devices. While in App mode, a ZUMNET-JBOX in Primary mode is the logical room controller for the space and is the device that should be used for configuration via the Zūm App. 35 +* In Secondary mode, the ZUMNET-JBOX acts as if it were a ZUMLINK-JBOX. It does not process any room control logic, and when connected to via Crestron Toolbox it will not be able to see any other ZUMLINK-* devices. Using Secondary mode is rare, and should only be used in cases where a spare ZUMNET-JBOX is being used to add a load to another ZUMNET-JBOX or replace a ZUMLINK-JBOX that has been lost or damaged. 33 33 34 - Whileinsecondarymode, theZUMNET-JBOX-*acts as ift werecannotdetect anydevicesonits37 +As of February, 2023, Crestron is shipping all ZUMNET-JBOX-* preconfigured in Secondary mode, though this may change in the future. 35 35 36 -== Security == 39 +== Security Considerations == 37 37 38 - Lorem41 +Although unlikely, it is technically possible that 39 39 40 40 = Control Paradigms = 41 41
- 1679688568997-208.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.9 KB - Content