11 11  = System Overview and Hardware Modes =
12 12  
13 -Zūm Wired systems consist of ZUMNET-JBOX-* room controllers and a number of connected ZUMLINK-* devices. ZUMLINK-* devices can be ZUMLINK-JBOX-* load controllers, ZUMLINK-OCC-* presence detectors, or ZUMLINK-KP-R-W keypads (wall switches). ZUMNET-JBOX-* and ZUMLINK-JBOX-* devices have additional inputs for third-party/non-system presence detectors, 0-10V photocells
13 +Zūm Wired systems consist of ZUMNET-JBOX-* room controllers and a number of connected ZUMLINK-* devices. ZUMLINK-* devices can be ZUMLINK-JBOX-* load controllers, ZUMLINK-OCC-* presence detectors, or ZUMLINK-KP-R-W keypads (wall switches). ZUMNET-JBOX-* and ZUMLINK-JBOX-* devices have additional inputs for third-party presence detectors, 0-10V analog photocells, and contact-closure local override.
14 14  
15 -== CNET Mode ==
15 +== App Mode ==
16 16  
17 17  Lorem
18 18  
19 -== App Mode ==
19 +== CNET Mode ==
20 20  
21 21  Lorem
22 22  
23 -== Primary vs Secondary ==
23 +== Primary vs Secondary Mode ==
24 24  
25 -Lorem
25 +(% class="box infomessage" %)
26 +(((
27 +Note: the terminology used for these modes was modified in .puf firmware v1.03.27 (device firmware v1.002.00026). Hardware delivered with older firmware will require the use of different commands to change modes during start-up.
28 +)))
26 26  
30 +ZUMNET-JBOX-* devices can be set to be either the Primary room controller or a Secondary load controller. There must only be one Primary ZUMNET-JBOX on a given Zūm Link bus, and in a networked system the Primary ZUMNET-JBOX is the one that should be connected to the Zūm Net. Secondary mode.
31 +
32 +* In Primary mode, the ZUMNET-JBOX acts as the Zūm Link host, and is able to detect all connected Zūm Link devices when connected to over Zūm Net in Crestron Toolbox. If also in App mode, a ZUMNET-JBOX in Primary mode will be the logical room controller for the space, and is the device that will be connected to via the Zūm App for configuration.
33 +* In Secondary mode, the ZUMNET-JBOX acts as if it were a ZUMLINK-JBOX
34 +
35 +As of February, 2023, all ZUMNET-JBOX-* devices ship preconfigured in Secondary mode,
36 +