Changes for page **General Overview and Design Considerations
Last modified by Alexander Mott on 2023/12/08 18:37
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,14 +6,14 @@ 6 6 ((( 7 7 Crestron Zūm Wired is a distributed lighting control system that has various global and local control options. Zūm Wired uses industry standard dimming protocols (DALI, 0-10V, and phase dimming) and advanced sensors to provide automated control of a building or facility's lighting. With certain designs, it is also possible to integrate control over DMX fixtures, building management systems, and other third-party devices (such as motorized shades and HVAC). 8 8 9 -The purpose of this article is to explain 9 +The purpose of this article is to explain various important concepts that must be understood in order to design a system that meets the requirements of all project stakeholders. 10 10 11 += System Overview and Hardware Modes = 11 11 13 +Zūm Wired systems consist of ZUMNET-JBOX-* room controllers and a number of connected ZUMLINK-* devices. ZUMLINK-* devices can be ZUMLINK-JBOX-* load controllers, ZUMLINK-OCC-* presence detectors, or ZUMLINK-KP-R-W keypads (wall switches). ZUMNET-JBOX-* and ZUMLINK-JBOX-* devices have additional inputs for third-party presence detectors, 0-10V analog photocells, and contact-closure local override. 12 12 13 - thevarious controlparadigmsavailable with Zūm Wired and the different modesthat Zūm Wired devices can be operated in, and the impacts on the system's capabilities that must be cons15 +== App Mode == 14 14 15 -= ZUMNET-JBOX Hardware Modes = 16 - 17 17 Lorem 18 18 19 19 == CNET Mode == ... ... @@ -20,14 +20,20 @@ 20 20 21 21 Lorem 22 22 23 -== AppMode ==23 +== Primary vs Secondary Mode == 24 24 25 -Lorem 25 +(% class="box infomessage" %) 26 +((( 27 +Note: the terminology used for these modes was modified in .puf firmware v1.03.27 (device firmware v1.002.00026). Hardware delivered with older firmware will require the use of different commands to change modes during start-up. 28 +))) 26 26 27 - ==Primary vs Secondary==30 +ZUMNET-JBOX-* devices can be set to be either the Primary room controller or a Secondary load controller. There must only be one Primary ZUMNET-JBOX on a given Zūm Link bus, and in a networked system the Primary ZUMNET-JBOX is the one that should be connected to the Zūm Net. Secondary mode. 28 28 29 -Lorem 32 +* In Primary mode, the ZUMNET-JBOX acts as the Zūm Link host, and is able to detect all connected Zūm Link devices when connected to over Zūm Net in Crestron Toolbox. If also in App mode, a ZUMNET-JBOX in Primary mode will be the logical room controller for the space, and is the device that will be connected to via the Zūm App for configuration. 33 +* In Secondary mode, the ZUMNET-JBOX acts as if it were a ZUMLINK-JBOX 30 30 35 +As of February, 2023, all ZUMNET-JBOX-* devices ship preconfigured in Secondary mode, 36 + 31 31 == Security == 32 32 33 33 Lorem