Changes for page **General Overview and Design Considerations
Last modified by Alexander Mott on 2023/12/08 18:37
To version 2.1
edited by Alexander Mott
on 2023/03/24 16:14
on 2023/03/24 16:14
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,77 +4,49 @@ 1 -{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 2 -{{toc/}} 3 -{{/box}} 4 4 5 -(% class="ro w" %)2 +(% class="box errormessage" %) 6 6 ((( 7 -Crestron Zūm Wired is a distributed lighting control system that has various global and local control options. Zūm Wired uses industry standard dimming protocols (DALI, 0-10V, and phase dimming) and advanced sensors to provide automated control of a building or facility's lighting. With certain designs, it is also possible to integrate control over DMX fixtures, building management systems, and other third-party devices (such as motorized shades and HVAC). 8 - 9 -The purpose of this article is to explain various important concepts that must be understood in order to design a system that meets the requirements of all project stakeholders. 10 - 11 -= System Overview and Hardware Modes = 12 - 13 -Zūm Wired systems consist of ZUMNET-JBOX-* room controllers and a number of connected ZUMLINK-* devices. ZUMLINK-* devices can be ZUMLINK-JBOX-* load controllers, ZUMLINK-OCC-* presence detectors, or ZUMLINK-KP-R-W keypads (wall switches). ZUMNET-JBOX-* and ZUMLINK-JBOX-* devices have additional inputs for third-party presence detectors, 0-10V analog photocells, and contact-closure local override. 14 - 15 -== App Mode == 16 - 17 -Lorem 18 - 19 -== CNET Mode == 20 - 21 -Lorem 22 - 23 -== Primary vs Secondary Mode == 24 - 25 -(% class="box infomessage" %) 4 +n/a 5 +))) 6 +(% class="box warningmessage" %) 26 26 ((( 27 - Note: the terminology used for these modes was modified in .puf firmware v1.03.27 (device firmware v1.002.00026). Hardware delivered with older firmware will require the use of different commands to change modes during start-up.8 +n/a 28 28 ))) 29 29 30 -ZUMNET-JBOX-* devices can be set to be either the Primary room controller or a Secondary load controller. There must only be one Primary ZUMNET-JBOX on a given Zūm Link bus, and in a networked system the Primary ZUMNET-JBOX is the one that should be connected to the Zūm Net. 11 +(% class="row" %) 12 +((( 13 +(% class="col-xs-12 col-sm-8" %) 14 +((( 15 +Lorem 31 31 32 - * In Primary mode, theZUMNET-JBOX acts as the Zūm Link host, and is able to detect all connected Zūm Link devices. If connected to in CrestronToolbox, a Primary ZUMNET-JBOX can beused to viewand manually address anyconnected ZUMLINK-* devices. While in App mode, a ZUMNET-JBOX in Primary mode is the logicalroom controllerforthe space andis thedevicethat should be used for configuration via the Zūm App.33 - * InSecondary mode,the ZUMNET-JBOX acts asif it were a ZUMLINK-JBOX. It does not process any room control logic, and when connected to via CrestronToolbox it will not beable tosee any other ZUMLINK-* devices. Using Secondarymodeis rare, and should only be used incases where a spare ZUMNET-JBOXis beingsedtoadd a load to another ZUMNET-JBOX or replace a ZUMLINK-JBOXthat has beenlost or damaged.17 +See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. 18 +See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details. 34 34 35 - Asof February, 2023, Crestron is shipping all ZUMNET-JBOX-* preconfiguredin Secondarymode, though this may change in the future.20 += Overview = 36 36 37 -== Security == 38 - 39 39 Lorem 40 40 41 -= Control Paradigms =24 += Hardware Modes = 42 42 43 -Designs for Zūm Wired systems are broadly categorized as either "standalone" or "networked" designs. Both standalone and networked systems should be designed with one ZUMNET-JBOX-* per room or logical control space connected to a number of ZUMLINK-* devices within that same space. In networked systems, there is also a control processor which provides centralized control of the entire system. ZUMNET-JBOX-* must be daisy-chained together with Zūm Net and then connected back to the processor. In standalone applications, there is no processor and no Zūm Net cabling connecting different rooms to each other. 44 - 45 - 46 -The difference between the two is that in a networked system there will be Zūm Net cabling connecting each ZUMNET-JBOX-* 47 - 48 -In standalone applications, each room has one ZUMNET-JBOX-* with a number of connected ZUMLINK-* devices. There is no Zūm Net connecting different rooms, 49 - 50 -Networked systems can be further subdivided into "Networked with Default Program" or "Networked with Custom Program". 51 - 52 -Depending on which control paradigm is selected, there will be various impacts to the hardware cost, start-up cost, start-up complexity, ease of maintenance, control capabilities, integration with third-party systems, available user interfaces, and the ability to meet a provided sequence of operations. 53 - 54 -== Standalone == 55 - 56 56 Lorem 57 57 58 -== N etworked ==28 +== CNET Mode == 59 59 60 60 Lorem 61 61 62 -== =Networkedwith DefaultProgram===32 +== App Mode == 63 63 64 64 Lorem 65 65 66 -== =Networked withSHOWRUNNER™===36 +== Primary vs Secondary == 67 67 68 68 Lorem 69 69 40 += Standalone vs Networked = 41 + 70 70 == Start-Up Considerations == 71 71 72 72 Lorem 73 73 74 -= =Processor Selection for Networked Systems ==46 += Processor Selection for Networked Systems = 75 75 76 76 Lorem 77 77 ... ... @@ -78,4 +78,26 @@ 78 78 = Device Count Limitations = 79 79 80 80 Lorem 53 + 81 81 ))) 55 + 56 + 57 +(% class="col-xs-12 col-sm-4" %) 58 +((( 59 +{{box title="**CONTENTS**"}} 60 +{{toc/}} 61 +{{/box}} 62 + 63 +(% class="wikigeneratedid" id="HFigure1" %) 64 +((( 65 +[[image:Templates.Article.Template.WebHome@image1.jpg]] 66 +//Figure 1: [[Sea>>https://commons.wikimedia.org/wiki/File:Isle_of_Icacos_II.jpg]]// 67 +))) 68 + 69 +(% class="wikigeneratedid" id="HFigure2" %) 70 +((( 71 +[[image:Templates.Article.Template.WebHome@image2.jpg]] 72 +//Figure 2: [[Waves>>https://commons.wikimedia.org/wiki/File:Culebra_-_Playa_de_Flamenco.jpg]]// 73 +))) 74 +))) 75 +)))
- image1.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.MarkKohlmann - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.8 KB - Content
- image2.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.MarkKohlmann - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.0 KB - Content