Changes for page **General Overview and Design Considerations
Last modified by Alexander Mott on 2023/12/08 18:37
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -27,12 +27,12 @@ 27 27 Note: the terminology used for these modes was modified in .puf firmware v1.03.27 (device firmware v1.002.00026). Hardware delivered with older firmware will require the use of different commands to change modes during start-up. 28 28 ))) 29 29 30 -ZUMNET-JBOX-* devices can be set to be either the Primary room controller or a Secondary load controller. There must only be one Primary ZUMNET-JBOX on a given Zūm Link bus, and in a networked system the Primary ZUMNET-JBOX is the one that should be connected to the Zūm Net. 30 +ZUMNET-JBOX-* devices can be set to be either the Primary room controller or a Secondary load controller. There must only be one Primary ZUMNET-JBOX on a given Zūm Link bus, and in a networked system the Primary ZUMNET-JBOX is the one that should be connected to the Zūm Net. Secondary mode. 31 31 32 -* In Primary mode, the ZUMNET-JBOX acts as the Zūm Link host, and is able to detect all connected Zūm Link devices . Ifconnected to in Crestron Toolbox,aPrimary ZUMNET-JBOX can be used to view and manually address any connectedZUMLINK-* devices. While in App mode, a ZUMNET-JBOX in Primary mode isthe logical room controller for the spaceshouldbeused forconfigurationvia the33 -* In Secondary mode, the ZUMNET-JBOX acts as if it were a ZUMLINK-JBOX . It does not process any room control logic, and when connected to via Crestron Toolbox it will not be able to see any other ZUMLINK-* devices. Using Secondary mode is rare, and should only be used in cases where a spare ZUMNET-JBOX is being used to add a load to another ZUMNET-JBOX or replace a ZUMLINK-JBOX that has been lost or damaged.32 +* In Primary mode, the ZUMNET-JBOX acts as the Zūm Link host, and is able to detect all connected Zūm Link devices when connected to over Zūm Net in Crestron Toolbox. If also in App mode, a ZUMNET-JBOX in Primary mode will be the logical room controller for the space, and is the device that will be connected to via the Zūm App for configuration. 33 +* In Secondary mode, the ZUMNET-JBOX acts as if it were a ZUMLINK-JBOX 34 34 35 -As of February, 2023, Crestron is shippingall ZUMNET-JBOX-* preconfigured in Secondary mode,though this may change in the future.35 +As of February, 2023, all ZUMNET-JBOX-* devices ship preconfigured in Secondary mode, 36 36 37 37 == Security == 38 38