Changes for page **General Overview and Design Considerations
Last modified by Alexander Mott on 2023/12/08 18:37
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,40 +4,40 @@ 4 4 5 5 (% class="row" %) 6 6 ((( 7 -Crestron Zūm Wired is a distributedlighting control system that has various global and localcontroloptions. Zūm Wired uses industrystandard dimming protocols (DALI, 0-10V, and phase dimming) and advanced sensors to provide automated control of a building or facility's lighting. With certain designs, it is also possible to integrate control over DMX fixtures, building management systems, and other third-party devices (such as motorized shades and HVAC).7 +Crestron Zūm Wired is a locally 8 8 9 -The purpose of this article is to explain various important concepts that must be understood in order to design a system that meets the requirements of all project stakeholders. 10 10 11 - = SystemOverviewandHardwareModes=10 +distributed lighting control platform that utilizes advanced sensors and industry standard dimming protocols to provide automated control of a building's lighting. 12 12 13 -Zūm Wired systems consist of ZUMNET-JBOX-* room controllers and a number of connected ZUMLINK-* devices. ZUMLINK-* devices can be ZUMLINK-JBOX-* load controllers, ZUMLINK-OCC-* presence detectors, or ZUMLINK-KP-R-W keypads (wall switches). ZUMNET-JBOX-* and ZUMLINK-JBOX-* devices have additional inputs for third-party presence detectors, 0-10V analog photocells, and contact-closure local override. 14 14 15 -== App Mode == 16 16 17 -Lorem 18 18 19 -== CNET Mode == 20 20 21 -Lorem 22 22 23 -== Primary vs Secondary Mode == 24 24 25 -(% class="box infomessage" %) 18 + 19 + 20 +(% class="box warningmessage" %) 26 26 ((( 27 - Note: the terminology usedfor these modeswasmodified in .puf firmwarev1.03.27 (device firmware v1.002.00026). Hardware delivered witholderfirmware will require the use of differentcommands to change modes during start-up.22 +Add more to intro 28 28 ))) 29 29 30 - ZUMNET-JBOX-*devices can be set to be eitherthe Primary room controller or a Secondary load controller.There must only be one Primary ZUMNET-JBOXon a given Zūm Link bus, andin a networkedsystemthe Primary ZUMNET-JBOX is the one that should be connected to the Zūm Net. Secondary mode.25 += Hardware Modes = 31 31 32 -* In Primary mode, the ZUMNET-JBOX acts as the Zūm Link host, and is able to detect all connected Zūm Link devices when connected to over Zūm Net in Crestron Toolbox. If also in App mode, a ZUMNET-JBOX in Primary mode will be the logical room controller for the space, and is the device that will be connected to via the Zūm App for configuration. 33 -* In Secondary mode, the ZUMNET-JBOX acts as if it were a ZUMLINK-JBOX 27 +Lorem 34 34 35 - Asof February, 2023, all ZUMNET-JBOX-*devices ship preconfiguredin Secondarymode,29 +== CNET Mode == 36 36 37 - == Security ==31 +Lorem 38 38 33 +== App Mode == 34 + 39 39 Lorem 40 40 37 +== Primary vs Secondary == 38 + 39 +Lorem 40 + 41 41 = Control Paradigms = 42 42 43 43 Designs for Zūm Wired systems are broadly categorized as either "standalone" or "networked" designs. Both standalone and networked systems should be designed with one ZUMNET-JBOX-* per room or logical control space connected to a number of ZUMLINK-* devices within that same space. In networked systems, there is also a control processor which provides centralized control of the entire system. ZUMNET-JBOX-* must be daisy-chained together with Zūm Net and then connected back to the processor. In standalone applications, there is no processor and no Zūm Net cabling connecting different rooms to each other.