Wiki source code of **Crestron Zūm Wired and SHOWRUNNER™
Last modified by Alexander Mott on 2023/12/08 18:49
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
22.1 | 1 | (% class="box successmessage" %) |
2 | ((( | ||
3 | Page for showrunner feature comparison, reasons for using showrunner, etc.; should also include information from old | ||
4 | ))) | ||
5 | |||
![]() |
1.1 | 6 | (% class="box errormessage" %) |
7 | ((( | ||
8 | n/a | ||
9 | ))) | ||
![]() |
3.1 | 10 | |
![]() |
1.1 | 11 | (% class="box warningmessage" %) |
12 | ((( | ||
13 | n/a | ||
14 | ))) | ||
15 | |||
![]() |
11.1 | 16 | {{box cssClass="floatinginfobox" title="**CONTENTS**"}} |
17 | {{toc/}} | ||
18 | {{/box}} | ||
19 | |||
![]() |
1.1 | 20 | (% class="row" %) |
21 | ((( | ||
22 | Lorem | ||
23 | |||
![]() |
6.1 | 24 | See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. |
25 | See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details. | ||
![]() |
1.1 | 26 | |
27 | = The SHOWRUNNER™ Advantage = | ||
28 | |||
29 | Lorem | ||
30 | |||
![]() |
14.1 | 31 | == Exclusive Features == |
![]() |
7.1 | 32 | |
33 | Lorem | ||
34 | |||
![]() |
14.1 | 35 | == Suitable for a Range of Applications == |
![]() |
13.1 | 36 | |
![]() |
7.1 | 37 | Lorem |
38 | |||
![]() |
14.1 | 39 | == Ease of Start-Up and Documentation == |
![]() |
12.1 | 40 | |
![]() |
14.1 | 41 | Every SHOWRUNNER™ job comes with a number of Chief Tools™ to simplify the start-up process and enable Agents and Technicians to for networked Zūm Wired systems. These tools include: |
![]() |
15.1 | 42 | |
![]() |
14.1 | 43 | * SRTakeoff spreadsheet provides the Technician with one location to view device addresses, record serial numbers, and track any issues discovered during start-up |
44 | * Zūm Wired Load Script generator enables technicians to easily create load scripts to streamline necessary configuration tasks based on the DeviceSummary.txt generated by Toolbox | ||
![]() |
12.1 | 45 | |
![]() |
14.1 | 46 | See the [[Starting Up Zūm Wired with SHOWRUNNER™>>doc:Design Guide.Hardware Design Guide.Crestron Zum Wired.Crestron Zum Wired Overview.WebHome||anchor="HStart-UpGuide"]] page for more information on starting up Zūm Wired systems with SHOWRUNNER™. |
![]() |
12.1 | 47 | |
![]() |
7.1 | 48 | == Support and Continued Development == |
49 | |||
50 | Lorem | ||
51 | |||
![]() |
10.2 | 52 | = Best Practices for Zūm Wired with SHOWRUNNER™ = |
53 | |||
![]() |
11.1 | 54 | Though it is possible to design a Zūm Wired system to use the standard ZUM-HUB4 program and then import rooms from SHOWRUNNER™, it is not recommended as it adds the expense of a custom program without taking advantage of any of the added functionality that SHOWRUNNER™ has to offer. |
![]() |
10.2 | 55 | |
![]() |
11.1 | 56 | Instead, to take full advantage of everything that SHOWRUNNER™ has to offer, follow these best practices: |
![]() |
1.1 | 57 | |
![]() |
11.1 | 58 | * Design the system to use SHOWRUNNER™ as the main program |
59 | * Set ZUMNET-JBOX-* devices in CNET mode after any App-specific configurations have been made | ||
![]() |
1.1 | 60 | |
![]() |
11.1 | 61 | Zūm |
![]() |
1.1 | 62 | |
![]() |
11.1 | 63 | SHOWRUNNER™ |
![]() |
1.1 | 64 | |
![]() |
16.1 | 65 | = Feature Comparison Tables = |
![]() |
1.1 | 66 | |
![]() |
18.1 | 67 | == SHOWRUNNER™ vs Default Program vs Standalone == |
![]() |
15.1 | 68 | |
![]() |
18.1 | 69 | (% class="box errormessage" %) |
70 | ((( | ||
![]() |
19.1 | 71 | need to verify information is up to date for this section |
![]() |
18.1 | 72 | ))) |
73 | |||
![]() |
16.1 | 74 | The below table compares some SHOWRUNNER exclusive features against networked systems using the default program and standalone systems using Zūm App mode. |
75 | |||
76 | |=Feature|=((( | ||
77 | **Networked** | ||
78 | |||
79 | **(**SHOWRUNNER™**)** | ||
80 | )))|=((( | ||
81 | **Networked** | ||
82 | |||
83 | **(HUB4)** | ||
84 | )))|=((( | ||
85 | **Zūm App** | ||
86 | |||
87 | **(Standalone)** | ||
88 | ))) | ||
89 | |(% colspan="4" %)**Hardware Requirements** | ||
90 | |Requires ZUMNET-JBOX-*|Y|Y|N | ||
![]() |
17.1 | 91 | |Requires 3 or 4-Series Control System|Y (Can use a number of different 3 and 4-Series processors)|Y (Requires ZUM-HUB4)|N |
![]() |
16.1 | 92 | |Requires Physical Presence in Room to Change Scenes|N|TBD|Y |
93 | |Maximum Rooms|TBD|1000|N/A | ||
94 | |(% colspan="4" %)**User Interfaces** | ||
95 | |Web Browser|((( | ||
96 | Crestron SmartGraphics XPanel | ||
97 | HTML5 UI | ||
98 | )))|HTML5 UI|N | ||
99 | |iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|N|Y* | ||
100 | |Touchscreens (Crestron TSW series)|Y|N|N | ||
101 | |(% colspan="4" %)**Features** | ||
102 | |Scene Recall|Y|Y|Y | ||
103 | |Override Fade Time for Scene Recall|Y|TBD|TBD | ||
104 | |Scene Save|Y|TBD|Y | ||
105 | |Load Control|Y|TBD|Y | ||
106 | |Demand Response|Y|Y|N | ||
107 | |Enable/Disable Occupancy|Y|Y|Y | ||
108 | |Override Occupancy Logic|Y|TBD|N | ||
109 | |Override|Y|TBD|N/A | ||
110 | |Plug Load On/Off|Y|Y|By Hardware | ||
111 | |Integration with Non-Zūm Crestron Hardware|Y|N|N | ||
112 | |Custom Zūm Keypad Programming|Y|TBD|Y, within the limits of the hardware | ||
113 | |New Feature Release Cycle|Aggressive|6-12 months|6-12 months | ||
114 | |Room Organization|((( | ||
115 | Organize According to Defined Nodes, multiple levels | ||
116 | Categorization to Filter by Tag | ||
117 | )))|Category/Room|((( | ||
118 | N/A | ||
119 | ))) | ||
120 | |Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A | ||
121 | |Network Topology|((( | ||
122 | * Flat | ||
123 | * Single Handoff to LAN w/ Control Subnet | ||
124 | (Requires CP4N/AV4/PRO4) | ||
125 | )))|Single Handoff to LAN w/ Control Subnet|N/A | ||
126 | |Network Addressing|((( | ||
127 | * Manual | ||
128 | * Customer (DHCP or Manual) | ||
129 | * DHCP: Control Subnet (Requires CP4N/AV4/PRO4) | ||
130 | )))|Control Subnet|N/A | ||
131 | |Firmware Updates|PUF Tool | ||
132 | Automatic Support on Roadmap|Automatic, Internet Connection Required|N/A | ||
133 | |Floorplans|Y|N|N/A | ||
134 | |(% colspan="4" %)**Calendar/Scheduling** | ||
135 | |Logic Type|Event Driven | ||
136 | Profile Support (Under Development)|Pattern assigned to Category|N/A | ||
137 | |Astronomical Clock|Y|Y, Per Category|N/A | ||
138 | |Holidays|Pattern|Hard Coded|N/A | ||
139 | |Custom Patterns|Y, Advanced Scheduler License|N|N/A | ||
140 | |(% colspan="4" %)**Integrations** | ||
141 | |A/V Integration: API|Y|Limited|N/A | ||
142 | |A/V Integration: Crestron EISC|Y|N|N/A | ||
143 | |A/V Integration: RS-232|Y|TBD|N/A | ||
144 | |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y|N/A | ||
145 | |BACNET Features|((( | ||
146 | Per Area Status: | ||
147 | Active Scene | ||
148 | Occupied | ||
149 | Occupancy Enabled | ||
150 | Individual Load Level | ||
151 | Photocell Level (per Photocell) | ||
152 | Plug Loads Enabled | ||
153 | System: | ||
154 | Demand Response Enabled | ||
155 | System Wide Override (Panic/Emergency) | ||
156 | ~* More Features added upon request | ||
157 | )))|((( | ||
158 | Per Room Status: | ||
159 | Online | ||
160 | On | ||
161 | Occupied | ||
162 | Daylighting Active | ||
163 | Device Battery is Low | ||
164 | Plug Loads Enabled | ||
165 | Occupancy Sensor Enabled | ||
166 | Current Daylight Level | ||
167 | Active Scene | ||
168 | \\System: | ||
169 | Demand Response Enabled | ||
170 | )))|N/A | ||
171 | |BACNET Settings Scope | ||
172 | (What Points are Exposed)|Per Area|Global|N/A | ||
173 | |BACNET Points Supported|Depends on Crestron License and Hardware|1000|N/A | ||
174 | |Crestron Fusion|Y|N|N/A | ||
175 | |Export to Zūm Floor Hub|Y, Licensed|N/A|N/A | ||
176 | |GLPAC|Y|N|N/A | ||
177 | |System to System Link|Y|N|N/A | ||
178 | |Minimum ZUM-NET Firmware|((( | ||
179 | CNET Mode: ZUM-WIRED 1.02.10 puf | ||
180 | ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) | ||
181 | )))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01 | ||
182 | |Minimum SHOWRUNNER™ Version|((( | ||
183 | CNET Mode: 3.016 | ||
184 | ZUM Mode: TBD | ||
185 | )))|N/A|N/A | ||
186 | |ZWMS (Zum Wired Master/Slave Mode)|MASTER|MASTER|MASTER or SLAVE | ||
187 | |ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|ZUM|ZUM | ||
188 | |||
![]() |
20.1 | 189 | === Caveats === |
![]() |
21.1 | 190 | |
![]() |
20.1 | 191 | * Consult Chief Integrations to verify sequence of operations if there are any concerns. |
192 | * Additional caveats: | ||
193 | ** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. | ||
194 | ** --Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. | ||
195 | ** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before ShowRunner can auto-discover hardware. | ||
![]() |
21.1 | 196 | |
![]() |
20.1 | 197 | === FAQ: === |
![]() |
21.1 | 198 | |
![]() |
20.1 | 199 | * I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? |
200 | //Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]// | ||
201 | * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? | ||
202 | //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// | ||
203 | |||
![]() |
16.1 | 204 | == Out-of-the-Box vs App vs Default Program vs Custom Program == |
205 | |||
206 | Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes. | ||
207 | |||
![]() |
15.1 | 208 | (% class="table-condensed" %) |
209 | |**Feature**|**Out of the Box Functionality**|((( | ||
210 | **Zūm App** | ||
211 | |||
212 | **(Standalone)** | ||
213 | )))|((( | ||
214 | **Networked** | ||
215 | |||
216 | **(HUB4)** | ||
217 | )))|**Custom Prog.**|**Notes** | ||
218 | |Keypads|Scn recall / OFF|*|*|*|Affect all load controllers excluding Plug controllers | ||
219 | |Presence detectors (Occ sensors)|Scn 1 / Scn 16|*|*|*|Presence detectors affect all load controllers | ||
220 | |Programmable scenes| |✓|*|*| | ||
221 | |Occupancy/Vacancy logic| |✓|*|*| | ||
222 | |Daylight Harvesting| |✓|*|*|J-box analog input support only, ZUMLINK- Daylight sensor via custom programming only. | ||
223 | |Customized Button Functions* | ||
224 | (Tap/Double-Tap/ Hold)| |✓|*|*|none, Off, On, Toggle, Scene 1-16, Export button to Hub | ||
225 | |Create a room configuration Template| |✓|*|*| | ||
226 | |Apply room configuration template| |✓|✓| |Identical hardware rooms required | ||
227 | |Universal 2-wire phase dimming up to 16A| |✓|*|*|ZUMLINK-EXP-DIMU support & Zūm App discovery/configuration | ||
228 | |DALI addressing, Broadcast and groups | ||
229 | support (Zūm Mode)| |✓|*|*|Allows control as Broadcast or 16 DALI Groups | ||
230 | |Device Firmware updating via Zūm APP(BLE).| |✓| | |Requires primary controller at ver. 1.2.60 | ||
231 | |DALI addressing and DALI group support (CNET Mode)| | | |✓|Allows addressing, grouping and control of 16 Dali Groups using Simpl #, Simpl Windows | ||
232 | |CNET / Zūm Mode Auto Switch| | | |✓|Automatically switches from CNET to Zum Mode when control system goes offline | ||
233 | |Load shedding| | |✓|*| | ||
234 | |Global/Multi/Cross-room KP| | |✓|*|Scenes, plug load and Occupancy enable/disable | ||
235 | |Timeclock event triggers| | |✓|*| | ||
236 | |DALI Type 6 TC| | | |✓| | ||
237 | |DALI Type 8 TC| | | |✓| | ||
238 | |Touch screen| | |*|✓|Hub4 support with mirror room modules | ||
239 | |Shades| | | |✓| | ||
240 | |AV integration| | |*|✓|Hub4 support with mirror room modules | ||
241 | |Energy Monitoring| | | |✓| | ||
242 | |((( | ||
243 | Floor Map | ||
244 | |||
245 | * denotes that can be used but not required to achieve functionality | ||