Wiki source code of *Crestron Zūm Wired and SHOWRUNNER™
Version 17.1 by Alexander Mott on 2023/03/28 16:45
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | (% class="box errormessage" %) | ||
2 | ((( | ||
3 | n/a | ||
4 | ))) | ||
5 | |||
6 | (% class="box warningmessage" %) | ||
7 | ((( | ||
8 | n/a | ||
9 | ))) | ||
10 | |||
11 | {{box cssClass="floatinginfobox" title="**CONTENTS**"}} | ||
12 | {{toc/}} | ||
13 | {{/box}} | ||
14 | |||
15 | (% class="row" %) | ||
16 | ((( | ||
17 | Lorem | ||
18 | |||
19 | See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. | ||
20 | See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details. | ||
21 | |||
22 | = The SHOWRUNNER™ Advantage = | ||
23 | |||
24 | Lorem | ||
25 | |||
26 | == Exclusive Features == | ||
27 | |||
28 | Lorem | ||
29 | |||
30 | == Suitable for a Range of Applications == | ||
31 | |||
32 | Lorem | ||
33 | |||
34 | == Ease of Start-Up and Documentation == | ||
35 | |||
36 | Every SHOWRUNNER™ job comes with a number of Chief Tools™ to simplify the start-up process and enable Agents and Technicians to for networked Zūm Wired systems. These tools include: | ||
37 | |||
38 | * SRTakeoff spreadsheet provides the Technician with one location to view device addresses, record serial numbers, and track any issues discovered during start-up | ||
39 | * Zūm Wired Load Script generator enables technicians to easily create load scripts to streamline necessary configuration tasks based on the DeviceSummary.txt generated by Toolbox | ||
40 | |||
41 | See the [[Starting Up Zūm Wired with SHOWRUNNER™>>doc:Design Guide.Hardware Design Guide.Crestron Zum Wired.Crestron Zum Wired Overview.WebHome||anchor="HStart-UpGuide"]] page for more information on starting up Zūm Wired systems with SHOWRUNNER™. | ||
42 | |||
43 | == Support and Continued Development == | ||
44 | |||
45 | Lorem | ||
46 | |||
47 | = Best Practices for Zūm Wired with SHOWRUNNER™ = | ||
48 | |||
49 | Though it is possible to design a Zūm Wired system to use the standard ZUM-HUB4 program and then import rooms from SHOWRUNNER™, it is not recommended as it adds the expense of a custom program without taking advantage of any of the added functionality that SHOWRUNNER™ has to offer. | ||
50 | |||
51 | Instead, to take full advantage of everything that SHOWRUNNER™ has to offer, follow these best practices: | ||
52 | |||
53 | * Design the system to use SHOWRUNNER™ as the main program | ||
54 | * Set ZUMNET-JBOX-* devices in CNET mode after any App-specific configurations have been made | ||
55 | |||
56 | Zūm | ||
57 | |||
58 | SHOWRUNNER™ | ||
59 | |||
60 | = Feature Comparison Tables = | ||
61 | |||
62 | == SHOWRUNNER == | ||
63 | |||
64 | The below table compares some SHOWRUNNER exclusive features against networked systems using the default program and standalone systems using Zūm App mode. | ||
65 | |||
66 | |=Feature|=((( | ||
67 | **Networked** | ||
68 | |||
69 | **(**SHOWRUNNER™**)** | ||
70 | )))|=((( | ||
71 | **Networked** | ||
72 | |||
73 | **(HUB4)** | ||
74 | )))|=((( | ||
75 | **Zūm App** | ||
76 | |||
77 | **(Standalone)** | ||
78 | ))) | ||
79 | |(% colspan="4" %)**Hardware Requirements** | ||
80 | |Requires ZUMNET-JBOX-*|Y|Y|N | ||
81 | |Requires 3 or 4-Series Control System|Y (Can use a number of different 3 and 4-Series processors)|Y (Requires ZUM-HUB4)|N | ||
82 | |Requires Physical Presence in Room to Change Scenes|N|TBD|Y | ||
83 | |Maximum Rooms|TBD|1000|N/A | ||
84 | |(% colspan="4" %)**User Interfaces** | ||
85 | |Web Browser|((( | ||
86 | Crestron SmartGraphics XPanel | ||
87 | HTML5 UI | ||
88 | )))|HTML5 UI|N | ||
89 | |iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|N|Y* | ||
90 | |Touchscreens (Crestron TSW series)|Y|N|N | ||
91 | |(% colspan="4" %)**Features** | ||
92 | |Scene Recall|Y|Y|Y | ||
93 | |Override Fade Time for Scene Recall|Y|TBD|TBD | ||
94 | |Scene Save|Y|TBD|Y | ||
95 | |Load Control|Y|TBD|Y | ||
96 | |Demand Response|Y|Y|N | ||
97 | |Enable/Disable Occupancy|Y|Y|Y | ||
98 | |Override Occupancy Logic|Y|TBD|N | ||
99 | |Override|Y|TBD|N/A | ||
100 | |Plug Load On/Off|Y|Y|By Hardware | ||
101 | |Integration with Non-Zūm Crestron Hardware|Y|N|N | ||
102 | |Custom Zūm Keypad Programming|Y|TBD|Y, within the limits of the hardware | ||
103 | |New Feature Release Cycle|Aggressive|6-12 months|6-12 months | ||
104 | |Room Organization|((( | ||
105 | Organize According to Defined Nodes, multiple levels | ||
106 | Categorization to Filter by Tag | ||
107 | )))|Category/Room|((( | ||
108 | N/A | ||
109 | ))) | ||
110 | |Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A | ||
111 | |Network Topology|((( | ||
112 | * Flat | ||
113 | * Single Handoff to LAN w/ Control Subnet | ||
114 | (Requires CP4N/AV4/PRO4) | ||
115 | )))|Single Handoff to LAN w/ Control Subnet|N/A | ||
116 | |Network Addressing|((( | ||
117 | * Manual | ||
118 | * Customer (DHCP or Manual) | ||
119 | * DHCP: Control Subnet (Requires CP4N/AV4/PRO4) | ||
120 | )))|Control Subnet|N/A | ||
121 | |Firmware Updates|PUF Tool | ||
122 | Automatic Support on Roadmap|Automatic, Internet Connection Required|N/A | ||
123 | |Floorplans|Y|N|N/A | ||
124 | |(% colspan="4" %)**Calendar/Scheduling** | ||
125 | |Logic Type|Event Driven | ||
126 | Profile Support (Under Development)|Pattern assigned to Category|N/A | ||
127 | |Astronomical Clock|Y|Y, Per Category|N/A | ||
128 | |Holidays|Pattern|Hard Coded|N/A | ||
129 | |Custom Patterns|Y, Advanced Scheduler License|N|N/A | ||
130 | |(% colspan="4" %)**Integrations** | ||
131 | |A/V Integration: API|Y|Limited|N/A | ||
132 | |A/V Integration: Crestron EISC|Y|N|N/A | ||
133 | |A/V Integration: RS-232|Y|TBD|N/A | ||
134 | |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y|N/A | ||
135 | |BACNET Features|((( | ||
136 | Per Area Status: | ||
137 | Active Scene | ||
138 | Occupied | ||
139 | Occupancy Enabled | ||
140 | Individual Load Level | ||
141 | Photocell Level (per Photocell) | ||
142 | Plug Loads Enabled | ||
143 | System: | ||
144 | Demand Response Enabled | ||
145 | System Wide Override (Panic/Emergency) | ||
146 | ~* More Features added upon request | ||
147 | )))|((( | ||
148 | Per Room Status: | ||
149 | Online | ||
150 | On | ||
151 | Occupied | ||
152 | Daylighting Active | ||
153 | Device Battery is Low | ||
154 | Plug Loads Enabled | ||
155 | Occupancy Sensor Enabled | ||
156 | Current Daylight Level | ||
157 | Active Scene | ||
158 | \\System: | ||
159 | Demand Response Enabled | ||
160 | )))|N/A | ||
161 | |BACNET Settings Scope | ||
162 | (What Points are Exposed)|Per Area|Global|N/A | ||
163 | |BACNET Points Supported|Depends on Crestron License and Hardware|1000|N/A | ||
164 | |Crestron Fusion|Y|N|N/A | ||
165 | |Export to Zūm Floor Hub|Y, Licensed|N/A|N/A | ||
166 | |GLPAC|Y|N|N/A | ||
167 | |System to System Link|Y|N|N/A | ||
168 | |Minimum ZUM-NET Firmware|((( | ||
169 | CNET Mode: ZUM-WIRED 1.02.10 puf | ||
170 | ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) | ||
171 | )))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01 | ||
172 | |Minimum SHOWRUNNER™ Version|((( | ||
173 | CNET Mode: 3.016 | ||
174 | ZUM Mode: TBD | ||
175 | )))|N/A|N/A | ||
176 | |ZWMS (Zum Wired Master/Slave Mode)|MASTER|MASTER|MASTER or SLAVE | ||
177 | |ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|ZUM|ZUM | ||
178 | |||
179 | == Out-of-the-Box vs App vs Default Program vs Custom Program == | ||
180 | |||
181 | Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes. | ||
182 | |||
183 | (% class="table-condensed" %) | ||
184 | |**Feature**|**Out of the Box Functionality**|((( | ||
185 | **Zūm App** | ||
186 | |||
187 | **(Standalone)** | ||
188 | )))|((( | ||
189 | **Networked** | ||
190 | |||
191 | **(HUB4)** | ||
192 | )))|**Custom Prog.**|**Notes** | ||
193 | |Keypads|Scn recall / OFF|*|*|*|Affect all load controllers excluding Plug controllers | ||
194 | |Presence detectors (Occ sensors)|Scn 1 / Scn 16|*|*|*|Presence detectors affect all load controllers | ||
195 | |Programmable scenes| |✓|*|*| | ||
196 | |Occupancy/Vacancy logic| |✓|*|*| | ||
197 | |Daylight Harvesting| |✓|*|*|J-box analog input support only, ZUMLINK- Daylight sensor via custom programming only. | ||
198 | |Customized Button Functions* | ||
199 | (Tap/Double-Tap/ Hold)| |✓|*|*|none, Off, On, Toggle, Scene 1-16, Export button to Hub | ||
200 | |Create a room configuration Template| |✓|*|*| | ||
201 | |Apply room configuration template| |✓|✓| |Identical hardware rooms required | ||
202 | |Universal 2-wire phase dimming up to 16A| |✓|*|*|ZUMLINK-EXP-DIMU support & Zūm App discovery/configuration | ||
203 | |DALI addressing, Broadcast and groups | ||
204 | support (Zūm Mode)| |✓|*|*|Allows control as Broadcast or 16 DALI Groups | ||
205 | |Device Firmware updating via Zūm APP(BLE).| |✓| | |Requires primary controller at ver. 1.2.60 | ||
206 | |DALI addressing and DALI group support (CNET Mode)| | | |✓|Allows addressing, grouping and control of 16 Dali Groups using Simpl #, Simpl Windows | ||
207 | |CNET / Zūm Mode Auto Switch| | | |✓|Automatically switches from CNET to Zum Mode when control system goes offline | ||
208 | |Load shedding| | |✓|*| | ||
209 | |Global/Multi/Cross-room KP| | |✓|*|Scenes, plug load and Occupancy enable/disable | ||
210 | |Timeclock event triggers| | |✓|*| | ||
211 | |DALI Type 6 TC| | | |✓| | ||
212 | |DALI Type 8 TC| | | |✓| | ||
213 | |Touch screen| | |*|✓|Hub4 support with mirror room modules | ||
214 | |Shades| | | |✓| | ||
215 | |AV integration| | |*|✓|Hub4 support with mirror room modules | ||
216 | |Energy Monitoring| | | |✓| | ||
217 | |((( | ||
218 | Floor Map | ||
219 | |||
220 | * denotes that can be used but not required to achieve functionality | ||
221 | )))| | |*|✓|Hub4 support with mirror room modules | ||
222 | ))) | ||
223 | |||
224 |