Changes for page **Crestron Zūm Wired and SHOWRUNNER™
Last modified by Alexander Mott on 2023/12/08 18:49
From version 22.1
edited by Alexander Mott
on 2023/12/08 18:49
on 2023/12/08 18:49
Change comment:
There is no comment for this version
To version 16.1
edited by Alexander Mott
on 2023/03/28 16:43
on 2023/03/28 16:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -* *Crestron Zūm Wired and SHOWRUNNER™1 +*Crestron Zūm Wired and SHOWRUNNER™ - Content
-
... ... @@ -1,8 +6,3 @@ 1 -(% class="box successmessage" %) 2 -((( 3 -Page for showrunner feature comparison, reasons for using showrunner, etc.; should also include information from old 4 -))) 5 - 6 6 (% class="box errormessage" %) 7 7 ((( 8 8 n/a ... ... @@ -64,13 +64,8 @@ 64 64 65 65 = Feature Comparison Tables = 66 66 67 -== SHOWRUNNER ™vs Default Program vs Standalone==62 +== SHOWRUNNER == 68 68 69 -(% class="box errormessage" %) 70 -((( 71 -need to verify information is up to date for this section 72 -))) 73 - 74 74 The below table compares some SHOWRUNNER exclusive features against networked systems using the default program and standalone systems using Zūm App mode. 75 75 76 76 |=Feature|=((( ... ... @@ -88,7 +88,7 @@ 88 88 ))) 89 89 |(% colspan="4" %)**Hardware Requirements** 90 90 |Requires ZUMNET-JBOX-*|Y|Y|N 91 -|Requires 3 or 4-Series Control System|Y (Can use a number of different 3 and 4-Series processors)|Y (Requires ZUM-HUB4)|N81 +|Requires 3 or 4-Series Control System|Y|Y (Requires ZUM-HUB4)|N 92 92 |Requires Physical Presence in Room to Change Scenes|N|TBD|Y 93 93 |Maximum Rooms|TBD|1000|N/A 94 94 |(% colspan="4" %)**User Interfaces** ... ... @@ -186,21 +186,6 @@ 186 186 |ZWMS (Zum Wired Master/Slave Mode)|MASTER|MASTER|MASTER or SLAVE 187 187 |ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|ZUM|ZUM 188 188 189 -=== Caveats === 190 - 191 -* Consult Chief Integrations to verify sequence of operations if there are any concerns. 192 -* Additional caveats: 193 -** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 194 -** --Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 195 -** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before ShowRunner can auto-discover hardware. 196 - 197 -=== FAQ: === 198 - 199 -* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 200 -//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]// 201 -* Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 202 -//If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 203 - 204 204 == Out-of-the-Box vs App vs Default Program vs Custom Program == 205 205 206 206 Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes.