Changes for page **Crestron Zūm Wired and SHOWRUNNER™
Last modified by Alexander Mott on 2023/12/08 18:49
From version 20.1
edited by Alexander Mott
on 2023/03/28 19:05
on 2023/03/28 19:05
Change comment:
There is no comment for this version
To version 22.1
edited by Alexander Mott
on 2023/12/08 18:49
on 2023/12/08 18:49
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -*Crestron Zūm Wired and SHOWRUNNER™ 1 +**Crestron Zūm Wired and SHOWRUNNER™ - Content
-
... ... @@ -1,3 +1,8 @@ 1 +(% class="box successmessage" %) 2 +((( 3 +Page for showrunner feature comparison, reasons for using showrunner, etc.; should also include information from old 4 +))) 5 + 1 1 (% class="box errormessage" %) 2 2 ((( 3 3 n/a ... ... @@ -182,18 +182,20 @@ 182 182 |ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|ZUM|ZUM 183 183 184 184 === Caveats === 190 + 185 185 * Consult Chief Integrations to verify sequence of operations if there are any concerns. 186 186 * Additional caveats: 187 187 ** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 188 188 ** --Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 189 189 ** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before ShowRunner can auto-discover hardware. 196 + 190 190 === FAQ: === 198 + 191 191 * I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 192 192 //Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]// 193 193 * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 194 194 //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 195 195 196 - 197 197 == Out-of-the-Box vs App vs Default Program vs Custom Program == 198 198 199 199 Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes.